Item | 12A Selfprrevstr W/Terms Luc*Bl |
Coil Volts | 24V DC |
Auxiliary Contact Form | Linked contacts (1 NO + 1 NC) IEC 60947-4-1, Mirror contact (1 NC) IEC 60947-1 |
Starter Type | Reversing |
Number of Poles | 3 |
Standards | EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier, CE, CCC, EAC, ASEFA, ATEX, Marine |
Width | 45 mm |
Features | Mercury Free, Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock & Vibration, Suitability For Isolation |
Hz | 40 to 60 Hz |
Height | 224 mm |
Depth | 126 mm |
Weight | 1.27 kg |
Operating Voltage | 690V AC |
Tightening Torque | Control circuit 7.08 to 10.62 lbf.in (0.8 to 1.2 N.m) flat 0.20 in (5 mm), Control circuit 7.08 to 10.62 lbf.in (0.8 to 1.2 N.m) Philips no 1 0.20 in (5 mm), Power circuit 16.82 to 22.13 lbf.in (1.9 to 2.5 N.m) flat 0.24 in (6 mm), Power circuit 16.82 to 22.13 lbf.in (1.9 to 2.5 N.m) Philips No 2 0.24 in (6 mm), Power circuit 16.82 to 22.13 lbf.in (1.9 to 2.5 N.m) pozidriv No 2 0.24 in (6 mm) |
Inrush Restraint Duration | 15 ms DC |
Immunity To Microbreaks | 3 ms control circuit |
Heat Dissipation | 2 W control circuit with LUCA, LUCB, LUCC, LUCD, 1.7 W control circuit with LUCM |
Product Or Component Type | Reversing power base |
IP Degree Of Protection | IP20 IEC 60947-1 front panel and wired terminals), IP20 IEC 60947-1 other faces), IP40 IEC 60947-1 front panel outside connection zone) |
Typical Current Consumption | 120 mA 24 V DC I maximum while closing, 120 mA 24 V DC I rms sealed |
Rated Operational Current | 12 A Less than or Equal to 440 V, 12 A 500 V, 9 A 690 V |
Resistance To Electrostatic Discharge | 8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2 |
Device Application | Motor control, Motor protection |
Auxiliary Contact Composition | 1 NO + 1 NC |
Protective Treatment | TH IEC 60068 |
Mechanical Durability | 15 Mcycles |
Product Name | TeSys Ultra |
Control Circuit Voltage | 24 V DC |
Shock Resistance | 10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27 |
Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
Auxiliary Contacts Type | Linked contacts 1 NO + 1 NC) IEC 60947-4-1, Mirror contact 1 NC) IEC 60947-1 |
Conventional Free Air Thermal Current | 12 A |
Utilisation Category | AC-43, AC-44, AC-41 |
Maximum Operating Rate | 3600 cyc/h |
Fire Resistance | 1760°F (960°C) parts supporting live components IEC 60695-2-12, 1202°F (650°C) IEC 60695-2-12 |
Operating Time | 150 ms with change of direction power circuit, 75 ms without change of direction power circuit, 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit, 75 ms closing with LUCM control circuit, 70 ms closing with LUCA, LUCB, LUCC, LUCD control circuit |
Ambient Air Temperature For Storage | -40 to 185°F (-40 to 85°C) |
Rated Operational Voltage | 690 V AC power circuit |
Vibration Resistance | 2 gn 5 to 300 Hz) power poles open IEC 60068-2-27, 4 gn 5 to 300 Hz) power poles closed IEC 60068-2-27 |
Connections - Terminals | Control circuit screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 1.5 mm?) flexible with cable end, Control circuit screw clamp terminals 1 0.00 to 0.00 in? (0.75 to 1.5 mm?) flexible without cable end, Control circuit screw clamp terminals 1 0.00 to 0.00 in? (0.75 to 1.5 mm?) rigid, Control circuit screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?) flexible with cable end, Control circuit screw clamp terminals 2 0.00 to 0.00 in? (0.75 to 1.5 mm?) flexible without cable end, Control circuit screw clamp terminals 2 0.00 to 0.00 in? (0.75 to 1.5 mm?) rigid, Power circuit screw clamp terminals 1 0.00 to 0.02 in? (1 to 10 mm?) rigid, Power circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 6 mm?) flexible with cable end, Power circuit screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) flexible without cable end, Power circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 6 mm?) flexible with cable end, Power circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 6 mm?) rigid, Power circuit screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) flexible without cable end |
Product Compatibility | Control unit LUC.X6BL, Control unit LUC.1XBL, Control unit LUC.05BL, Control unit LUC.12BL |
Fixing Mode | Clipped DIN rail, Screw-fixed plate) |
Rated Insulation Voltage | 690 V IEC 60947-6-2 3, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1 |
Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N |
Poles Description | 3P |
Ambient Air Temperature For Operation | -13 to 140°F (-25 to 60°C) with LUCM, -13 to 158°F (-25 to 70°C) with LUCA, LUCB, LUCC, LUCD |
Compatibility Code | LU2B |
Operating Altitude | 6561.68 ft (2000 m) |
Resistance To Radiated Fields | 9.14 V/m (10 V/m) 3 IEC 61000-4-3 |
Product Certifications | CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Immunity To Voltage Dips | 70% / 500 ms IEC 61000-4-11 |
Rated Service Breaking Capacity | 50 kA 230 V, 50 kA 440 V, 10 kA 500 V, 4 kA 690 V |
Suitability For Isolation | Yes |
Rated Impulse Withstand Voltage | 6 kVIEC 60947-6-2 |
Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
Control Circuit Voltage Limits | 14.5 V DC drop-out, 20 to 27 V DC in operation |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
12A Selfprrevstr W/Terms Luc*Bl, 24V DC, 3 Poles, SCHNEIDER ELECTRIC, Mfr# LU2B12BL