Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 18 A |
Action | Reversing |
Full Load Amps-Resistive | 32 A |
Number of Poles | 3 |
Coil Volts | 120 V AC |
Reversing | Yes |
HP @ 1 Phase - 120V | 1 hp |
HP @ 1 Phase - 230V | 3 |
HP @ 1 Phase - 240V | 3 hp |
Height | 3.54 in |
HP @ 3 Phase - 208V | 5 hp |
Width | 3.54 in |
HP @ 3 Phase - 240V | 5 hp |
HP @ 3 Phase - 575V | 15 hp |
Depth | 3.54 in |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 10 hp |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Frame / Series / Class / Code | TeSys |
Includes | Electrical Interlock, Mechanical Interlock |
Auxiliary Contact Form | 1NO/1NC |
Series | TeSys Deca |
NEMA Size | Not Applicable |
Rated Breaking Capacity | 300 A @ 440V |
IP Rating | IP20 |
Electrical Durability | 1.65 Mcycles (18 A, AC-3, Less than 440 V), 1 Mcycles (32 A, AC-1, Less than 440 V) |
Application | Motor Control, Resistive Load |
Max. Operating Watts | 4 kW (at 220 to 230V AC 50 Hz), 7.5 kW (at 380 to 400V AC 50 Hz), 9 kW (at 415 to 440V AC 50 Hz), 10 kW (at 500V AC 50 Hz), 10 kW (at 660 to 690V AC 50 Hz) |
Operating Speed | 3600 cycles per hr |
Rated Insulation Volts | 600/690V |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Mounts On | Plate, Rail |
Max. Temperature | 850°C |
Non-Overlap Time | 1.5 ms |
Impedance | 2.5 mOhm |
Switching Voltage | 17 V (Signalling Circuit) |
Switching Current | 5 mA (Signalling Circuit) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Features | Without Built-In Suppressor Module, Preassembled with Reversing Power Busbar |
Fire Rating | UL 94 V1 |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit) |
Includes Protective Cover | Yes |
Rated Short-Time Withstand Current | 40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Tightening Torque | 1.7 Nm (Control Circuit), 1.7 to 2.5 Nm (Power Circuit) |
Electrical Connection | Screw Clamp Terminals |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Fuse Amps | 10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit) |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 32 A (at 60°C Power Circuit) |
Overvoltage Category | CAT III |
Net Weight | 0.707 kg |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Inrush VA | 70 VA |
Rated Voltage | 690V AC, 300V DC |
Impulse Withstand Voltage | 6 kV |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Mechanical Durability | 15 Mcycles |
Working Height | Up to 9842.52 ft |
Signalling Circuit Frequency | 25 to 400 Hz |
Watts Loss | 2 to 3W |
Mounting Style | DIN Rail, Plate |
Embedded Surge Suppressor | No |
Maximum Voltage Rating | 690V AC |
Frequency | 50/60 Hz |
Phase | Three |
Overall Depth | 3.39 in |
Electrical Operating Durability | 1,000,000, 1,650,000 |
Horsepower @ Three Phase - 480V AC | 10 hp |
Coil Voltage | 120V AC |
NEMA Enclosure Rating | No Enclosure |
Horsepower @ Three Phase - 208V AC | 5 hp |
Resistance Properties | Fire Resistant, Insulation Resistant |
Terminal Connection Type | Screw Clamp Terminals |
Horsepower @ Single Phase - 240V AC | 3 hp |
Minimum Operating Temperature | -40 Degrees F |
Overall Width | 3.54 in |
Mechanical Operating Durability | 15,000,000 |
Horsepower @ Three Phase - 240V AC | 5 hp |
Full Load Current - Inductive | 18 A |
Horsepower @ Single Phase - 120V AC | 1 hp |
Overall Height | 3.03 in |
Horsepower @ Three Phase - 600V AC | 15 hp |
Number of Auxillary Contacts | 2 |
Number of Normally Open Main Contacts | 3 |
NEMA Enclosure Material | Not Applicable |
Reversing Capability | Reversing |
Contactor Style | IEC |
Includes Auxiliary Contacts | Yes |
Maximum Operating Temperature | 140 Degrees F |
Minimum Switching Current | 5 mA for signalling circuit |
Product Certifications | DNV, CSA, CCC, UL, GL, LROS (Lloyds register of shipping), BV, RINA, GOST, UKCA |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC |
Average Impedance | 2.5 mOhm - Ith 32 A 50 Hz for power circuit |
Inrush Power in VA | 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Protective Treatment | TH IEC 60068-2-30 |
Rated Operational Current | 18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Device Presentation | Preassembled with reversing power busbar |
Motor Power KW | 4 kW at 220 to 230 V AC 50 Hz, 7.5 kW at 380 to 400 V AC 50 Hz, 9 kW at 415 to 440 V AC 50 Hz, 10 kW at 500 V AC 50 Hz, 10 kW at 660 to 690 V AC 50 Hz |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
Contactor Application | Motor control, Resistive load |
Climatic Withstand | IACS E10, IEC 60947-1 Annex Q category D |
Heat Dissipation | 2 to 3 W 50/60 Hz |
Power Pole Contact Composition | 3 NO |
IRMS Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 300 A at 440 V for power circuit conforming to IEC 60947 |
Control Circuit Type | AC 50/60 Hz |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Ambient Air Temperature For Operation | -40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating |
Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL |
Connections - Terminals | Control circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)flexible without cable end, Control circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?)flexible without cable end, Control circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)flexible with cable end, Control circuit screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?)flexible with cable end, Control circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)solid, Control circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?)solid, Power circuit screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 6 mm?)flexible without cable end, Power circuit screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?)flexible without cable end, Power circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 6 mm?)flexible with cable end, Power circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?)flexible with cable end, Power circuit screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 6 mm?)solid, Power circuit screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?)solid |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1, 50 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 35 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Pollution Degree | 3 |
Hold-In Power Consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C)) |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Ambient Air Temperature For Storage | -76 to 176°F (-60 to 80°C) |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Rated Short Time Withstand Current | 40 A 104°F (40°C) - 10 min for power circuit, 84 A 104°F (40°C) - 1 min for power circuit, 145 A 104°F (40°C) - 10 s for power circuit, 240 A 104°F (40°C) - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
Product Or Component Type | Reversing contactor |
Product Name | TeSys D, TeSys Deca |
Control Circuit Voltage | 120 V AC 50/60 Hz |
Front Cover | With |
Flame Retardance | V1 conforming to UL 94 |
Mechanical Robustness | Vibrations contactor open2 Gn, 5 to 300 Hz, Vibrations contactor closed4 Gn, 5 to 300 Hz, Shocks contactor open10 Gn for 11 ms, Shocks contactor closed15 Gn for 11 ms |
Interlocking Type | Electrical and mechanical |
Utilisation Category | AC-3, AC-1 |
Minimum Switching Voltage | 17 V for signalling circuit |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit, 32 A (at 140°F (60°C)) for power circuit |
Auxiliary Contact Composition | 1 NO + 1 NC |
Poles Description | 3P |
Mounting Support | Plate, Rail |
Motor Power HP | 1 hp at 115 V AC 60 Hz for 1 phase motors, 3 hp at 230/240 V AC 60 Hz for 1 phase motors, 5 hp at 200/208 V AC 60 Hz for 3 phase motors, 5 hp at 230/240 V AC 60 Hz for 3 phase motors, 10 hp at 460/480 V AC 60 Hz for 3 phase motors, 15 hp at 575/600 V AC 60 Hz for 3 phase motors |
IP Degree Of Protection | IP20 front face IEC 60529 |
Coil Technology | Without built-in suppressor module |
Power Dissipation Per Pole | 0.8 W AC-3, 2.5 W AC-1 |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 120 V AC, 18 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2D18G7V
-$13.14 / ea
with subscription
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 3, Full Load Current - Inductive 18 A, Reversing Capability Reversing, Overall Height 3.03 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 5 hp
9999 in stock
Must order in multiples of 1
Subtotal:
$437.99
You must be logged in to post a review.