Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 40 A |
Full Load Amps-Resistive | 60 A |
Number of Poles | 3 |
Coil Volts | 110 V AC |
Height | 127 mm |
HP @ 1 Phase - 240V | 5 hp |
HP @ 3 Phase - 208V | 10 hp |
Width | 75 mm |
Depth | 119 mm |
HP @ 3 Phase - 575V | 30 hp |
HP @ 3 Phase - 240V | 10 hp |
HP @ 3 Phase - 480V | 30 hp |
Aux. Contact Configuration | 1NO/1NC |
Series | LC1D |
Standards | EN 60947-5-1, IEC 60947-5-1, EN 60947-4-1, UL 508, IEC 60947-4-1, CSA C22.2 No 14, CCC, CSA, GL, RINA, UL, DNV, LROS, GOST, BV |
Max. Operating Watts | 18.5 kW (at 380 to 400V AC 50 Hz AC-3), 22 kW (at 500V AC 50 Hz AC-3), 30 kW (at 660 to 690V AC 50 Hz) AC-3), 22 kW (at 1000V AC 50 Hz AC-3), 22 kW (at 415V AC 50 Hz AC-3), 22 kW (at 440V AC 50 Hz) AC-3), 11 kW (at 220 to 230V AC 50 Hz AC-3), 9 kW (at 400V AC 50 Hz AC-4), 18.5 kW (at 380 to 400V AC 50 Hz AC-3e), 22 kW (at 500V AC 50 Hz AC-3e), 30 kW (at 660 to 690V AC 50 Hz AC-3e), 22 kW(at 1000V AC 50 Hz AC-3e), 22 kW(at 415V AC 50 Hz AC-3e), 22 kW (at 440V AC 50 Hz AC-3e), 11 kW(at 220 to 230V AC 50 Hz AC-3e) |
Fire Rating | UL 94 V1 |
Electrical Connection | Screw Clamp Terminals |
Net Weight | 1.4 kg |
Tightening Torque | 1.7 Nm (Control Circuit), 5 Nm (Power Circuit) |
Mechanical Durability | 6 Mcycles |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Working Height | Up to 9842.52 ft |
Fuse Amps | 10 A (Control Circuit), 80 A (Type 1 and 2 Power Circuit) |
Rated Insulation Volts | 600/690V |
Rated Voltage | 690V AC |
Switching Current | 5 mA (Control Circuit) |
Inrush VA | 140 VA (at 20°C), 160 VA (at 20°C) |
IP Rating | IP2X |
Application | Motor Control, Resistive Load |
Operating Speed | 3600 cycles per hr |
Switching Voltage | 17 V (Control Circuit) |
Max. Temperature | 850°C |
Overvoltage Category | CAT III |
Mounts On | Plate, Rail |
Features | Without Built-In Bi-Directional Peak Limiting Diode Suppressor |
Impulse Withstand Voltage | 8 kV |
Hold VA | 13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C) |
Rated Making Capacity | 800 A @ 440V (Power Circuit), 140 A (AC Control Circuit) |
Operating Time | 4 to 19 ms (Opening), 12 to 26 ms (Closing) |
Rated Breaking Capacity | 800 A @ 440V |
Non-Overlap Time | 1.5 ms |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free |
Watts Loss | 4 to 5W |
Includes Protective Cover | Yes |
Insulation Resistance Range | Greater Than 10 Mohms (Control Circuit) |
Thermal Amperage | 10 A (at 60°C Control Circuit), 60 A (at 60°C Power Circuit) |
Product Certifications | CCC, CSA, GL, RINA, UL, DNV, LROS (Lloyds register of shipping), GOST, BV |
Mounting Support | Rail, Plate |
Poles Description | 3P |
Associated Fuse Rating | 10 A gG for control circuit conforming to IEC 60947-5-1, 80 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 80 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Auxiliary Contact Composition | 1 NO + 1 NC |
Power Dissipation Per Pole | 5.4 W AC-1, 2.4 W AC-3, 2.4 W AC-3e |
IRMS Rated Making Capacity | 800 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for control circuit conforming to IEC 60947-5-1 |
Rated Insulation Voltage | Control circuit 600 V CSA, Control circuit 600 V UL, Power circuit 600 V CSA, Power circuit 600 V UL, Control circuit 690 V IEC 60947-1, Power circuit 690 V IEC 60947-1 |
Flame Retardance | V1 conforming to UL 94 |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz |
Rated Operational Current | 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 60 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
Inrush Power in VA | 140 VA cos phi 0.75 (at 68°F (20°C)), 160 VA cos phi 0.75 (at 68°F (20°C)) |
Control Circuit Voltage | 110 V AC 50/60 Hz |
Product Or Component Type | Contactor |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
Pole Contact Composition | 3 NO |
Motor Power KW | 18.5 kW at 380 to 400 V AC 50 Hz (AC-3), 22 kW at 500 V AC 50 Hz (AC-3), 30 kW at 660 to 690 V AC 50 Hz (AC-3), 22 kW at 1000 V AC 50 Hz (AC-3), 22 kW at 415 V AC 50 Hz (AC-3), 22 kW at 440 V AC 50 Hz (AC-3), 11 kW at 220 to 230 V AC 50 Hz (AC-3), 9 kW at 400 V AC 50 Hz (AC-4), 18.5 kW at 380 to 400 V AC 50 Hz (AC-3e), 22 kW at 500 V AC 50 Hz (AC-3e), 30 kW at 660 to 690 V AC 50 Hz (AC-3e), 22 kW at 1000 V AC 50 Hz (AC-3e), 22 kW at 415 V AC 50 Hz (AC-3e), 22 kW at 440 V AC 50 Hz (AC-3e), 11 kW at 220 to 230 V AC 50 Hz (AC-3e) |
Utilisation Category | AC-3, AC-1, AC-4, AC-2, AC-3e |
Hold-In Power Consumption in VA | 13 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 15 VA 50 Hz cos phi 0.3 (at 68°F (20°C)) |
IP Degree Of Protection | IP2X IEC 60529, IP2X VDE 0106 |
Connections - Terminals | Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: rigid, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: rigid, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Power circuit: screw terminals 1 0.00 to 0.04 in? (2.5 to 25 mm?) - cable stiffness: rigid, Power circuit: screw terminals 2 0.00 to 0.02 in? (2.5 to 16 mm?) - cable stiffness: rigid, Power circuit: screw terminals 1 0.00 to 0.04 in? (2.5 to 25 mm?) - cable stiffness: flexible without cable end, Power circuit: screw terminals 2 0.00 to 0.02 in? (2.5 to 16 mm?) - cable stiffness: flexible without cable end, Power circuit: screw terminals 1 0.00 to 0.04 in? (2.5 to 25 mm?) - cable stiffness: flexible with cable end, Power circuit: screw terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible with cable end |
Contactor Application | Motor control, Resistive load |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Minimum Switching Voltage | 17 V for control circuit |
Climatic Withstand | IACS E10 exposure to damp heat |
Rated Impulse Withstand Voltage | 8 kV IEC 60947 |
Protective Cover | With |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for control circuit, 60 A (at 140°F (60°C)) for power circuit |
Maximum Horse Power Rating | 3 hp at 115 V AC 60 Hz for 1 phase motors, 5 hp at 230/240 V AC 60 Hz for 1 phase motors, 10 hp at 200/208 V AC 60 Hz for 3 phase motors, 10 hp at 230/240 V AC 60 Hz for 3 phase motors, 30 hp at 460/480 V AC 60 Hz for 3 phase motors, 30 hp at 575/600 V AC 60 Hz for 3 phase motors |
Insulation Resistance | Greater than 10 MOhm for control circuit |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Control Circuit Type | AC 50/60 Hz |
Coil Technology | Without built-in bidirectional peak limiting diode suppressor |
Minimum Switching Current | 5 mA for control circuit |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Heat Dissipation | 4 to 5 W at 50/60 Hz for control circuit |
Mechanical Robustness | Shocks contactor opened 10 Gn for 11 ms), Shocks contactor closed 15 Gn for 11 ms), Vibrations contactor opened 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz) |
Country of Origin (subject to change) | Czechia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 110 V AC, 40 A, SCHNEIDER ELECTRIC, Mfr# LC1D40F7
$352,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor
9999 in stock
Must order in multiples of 1
Subtotal:
$352.99
You must be logged in to post a review.
Reviews