Full Load Amps-Inductive | 115 A |
Item | IEC Magnetic Contactor |
Full Load Amps-Resistive | 200 A |
Number of Poles | 3 |
Coil Volts | 120 V AC |
Height | 158 mm |
HP @ 3 Phase - 208V | 30 hp |
Width | 120 mm |
HP @ 3 Phase - 575V | 100 hp |
Depth | 136 mm |
HP @ 3 Phase - 240V | 40 hp |
HP @ 3 Phase - 480V | 75 hp |
Aux. Contact Configuration | 1NO/1NC |
Series | LC1D |
Standards | CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, UL, CSA, GOST, BV, GL, LROS, RINA, DNV, CCC, UKCA, CE, THIEC 60068-2-30 |
Features | Without Built-In Suppressor Module |
Application | Motor Control, Resistive Load |
Impedance | 0.6 mOhm |
Working Height | Up to 9842.52 ft |
Electrical Connection | Screw Clamp Terminals |
Hold VA | 22 VA |
Tightening Torque | 1.2 Nm (Control Circuit), 12 Nm (Power Circuit) |
Switching Current | 5 mA (Signalling Circuit) |
Includes Protective Cover | Yes |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Control Circuit Voltage Limits | Operational AC: 0.85 to 1.1 Uc (at -40 to 55°C 60 Hz), 1 to 1.1 Uc (at 55 to 70°C 60 Hz), Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 60 Hz) |
Electrical Durability | 0.8 Mcycles (200 A, AC-1, Less than 440 V), 0.95 Mcycles (115 A, AC-3, Less than 440 V), 0.95 Mcycles (115 A, AC-3e, Less than 440 V) |
Signalling Circuit Frequency | 25 to 400 Hz |
Rated Voltage | 1000V AC, 300V DC |
Watts Loss | 3 to 8W |
Rated Making Capacity | 1260 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Rated Short-Time Withstand Current | 250 A (at 40°C for 10 min Power Circuit), 550 A (at 40°C for 1 min Power Circuit), 950 A (at 40°C for 10 s Power Circuit), 1100 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Rated Breaking Capacity | 1100 A @ 440V |
Thermal Amperage | 200 A (at 60°C Power Circuit) |
Fuse Amps | 250 A (Type 1 Power Circuit), 200 A (Type 2 Power Circuit), 10 A (Signalling Circuit) |
Overvoltage Category | CAT III |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open) |
Switching Voltage | 17 V (Signalling Circuit) |
IP Rating | IP20 |
Inrush VA | 300 VA |
Non-Overlap Time | 1.5 ms |
Max. Operating Watts | 30 kW (at 220 to 230V AC 50/60 Hz AC-3), 55 kW (at 380 to 400V AC 50/60 Hz AC-3), 59 kW 415 to (at 440V AC 50/60 Hz AC-3), 75 kW (at 500V AC 50/60 Hz AC-3), 80 kW (at 660 to 690V AC 50/60 Hz AC-3), 65 kW (at 1000V AC 50/60 Hz AC-3), 18.5 kW (at 400V AC 50/60 Hz AC-4), 30 kW (at 220 to 230V AC 50/60 Hz AC-3e), 55 kW (at 380 to 400V AC 50/60 Hz AC-3e), 59 kW 415 to (at 440V AC 50/60 Hz AC-3e), 75 kW (at 500V AC 50/60 Hz AC-3e), 80 kW (at 660 to 690V AC 50/60 Hz AC-3e), 65 kW (at 1000V AC 50/60 Hz AC-3e) |
Rated Insulation Volts | 600/1000V (Power Circuit), 600/690V (Signalling Circuit) |
Net Weight | 2.5 kg |
Impulse Withstand Voltage | 8 kV |
Operating Speed | 2400 cycles per hr |
Max. Temperature | 850°C |
Environmental Attributes | Mercury Free, PVC Free, Pollution Degree 3 |
Operating Time | 6 to 20 ms (Opening), 20 to 50 ms (Closing) |
Mounts On | Plate, Rail |
Mechanical Durability | 8 Mcycles |
Fire Rating | UL 94 V1 |
Country of Origin (subject to change) | Czechia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 120 V AC, 115 A, SCHNEIDER ELECTRIC, Mfr# LC1D115G6
$510,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor
9999 in stock
Must order in multiples of 1
Subtotal:
$510.99
You must be logged in to post a review.