Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 50 A |
Full Load Amps-Resistive | 80 A |
Number of Poles | 3 |
Coil Volts | 120 V AC |
Height | 122 mm |
HP @ 1 Phase - 240V | 7 1/2 hp |
HP @ 3 Phase - 208V | 15 hp |
Width | 55 mm |
HP @ 3 Phase - 240V | 15 hp |
Depth | 119 mm |
HP @ 3 Phase - 575V | 40 hp |
HP @ 3 Phase - 480V | 40 hp |
Aux. Contact Configuration | 1NO/1NC |
Series | TeSys Deca |
NEMA Size | Not Applicable |
Standards | CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 |
Auxiliary Contact Form | 1NO/1NC |
Non-Overlap Time | 1.5 ms |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free |
Mechanical Durability | 6 Mcycles |
Max. Operating Watts | 22 kW (at 380 to 400V AC 50/60 Hz AC-3), 25 kW (at 415V AC 50/60 Hz AC-3), 30 kW (at 440V AC 50/60 Hz AC-3), 30 kW (at 500V AC 50/60 Hz AC-3), 33 kW (at 660 to 690V AC 50/60 Hz AC-3), 15 kW (at 220 to 230V AC 50/60 Hz AC-3), 11 kW (at 400V AC 50/60 Hz AC-4) |
Rated Breaking Capacity | 900 A @ 440V |
Fire Rating | UL 94 V1 |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at 60°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at 60°C 50 Hz), 0.85 to 1.1 Uc (at 60°C 60 Hz) |
Includes Protective Cover | Yes |
Electrical Connection | Screw Clamp Terminals |
Operating Speed | 3600 cycles per hr |
Max. Temperature | 850°C |
Insulation Resistance Range | Greater Than 10 Mohms (Control Circuit) |
IP Rating | IP20 |
Thermal Amperage | 10 A (at 60°C Control Circuit), 80 A (at 60°C Power Circuit) |
Operating Time | 12 to 26 ms (Closing), 4 to 19 ms (Opening) |
Inrush VA | 140 VA (at 20°C), 160 VA (at 20°C) |
Impulse Withstand Voltage | 6 kV |
Working Height | 9842.52 ft |
Mounts On | Plate, Rail |
Overvoltage Category | CAT III |
Rated Making Capacity | 140 A (AC Control Circuit), 900 A @ 440V (Power Circuit) |
Impedance | 1.5 mOhm |
Rated Voltage | 690V AC |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Application | Motor Control, Resistive Load |
Switching Current | 5 mA (Control Circuit) |
Hold VA | 13 VA (at 50 Hz 20°C), 15 VA (at 60 Hz 20°C) |
Switching Voltage | 17 V (Control Circuit) |
Tightening Torque | 1.2 Nm (Control Circuit), 5 Nm (Power Circuit) |
Watts Loss | 4 to 5W |
Rated Insulation Volts | 600/690V |
Fuse Amps | 10 A (Control Circuit), 100 A (Type 1 and 2 Power Circuit) |
Features | Without Built-In Bi-Directional Peak Limiting Diode Suppressor |
Net Weight | 1.4 kg |
Horsepower @ Three Phase - 600V AC | 40 hp |
Full Load Current - Inductive | 150 A |
Minimum Operating Temperature | 23 Degrees F |
Horsepower @ Three Phase - 480V AC | 40 hp |
Overall Height | 4.8 in |
Maximum Operating Temperature | 140 Degrees F |
Includes Auxiliary Contacts | Yes |
Horsepower @ Three Phase - 240V AC | 15 hp |
Horsepower @ Single Phase - 120V AC | 3 hp |
NEMA Enclosure Rating | No Enclosure |
Coil Voltage | 120V AC |
Full Load Current - Resistive | 200 A |
Mechanical Operating Durability | 6,000,000 |
Maximum Voltage Rating | 120V AC |
Overall Width | 2.17 in |
Embedded Surge Suppressor | No |
Contactor Style | IEC |
Number of Normally Closed Main Contacts | 0 |
Overall Depth | 4.72 in |
Reversing Capability | Non-Reversing |
Terminal Connection Type | Screw Clamp Terminals |
Horsepower @ Single Phase - 240V AC | 7 1/2 hp |
Number of Normally Open Main Contacts | 1 |
Phase | Three |
Number of Auxillary Contacts | 3 |
Frequency | 50/60 Hz |
Horsepower @ Three Phase - 208V AC | 15 hp |
Mounting Style | DIN Rail |
Pole Contact Composition | 3 NO |
Maximum Horse Power Rating | 3 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA, 3 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL, 15 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to CSA, 15 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to UL, 15 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to CSA, 15 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to UL, 40 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to CSA, 40 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to UL, 40 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to CSA, 40 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to UL, 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to CSA, 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to UL |
Motor Power KW | 22 kW at 380 to 400 V AC 50/60 Hz (AC-3), 25 kW at 415 V AC 50/60 Hz (AC-3), 30 kW at 440 V AC 50/60 Hz (AC-3), 30 kW at 500 V AC 50/60 Hz (AC-3), 33 kW at 660 to 690 V AC 50/60 Hz (AC-3), 15 kW at 220 to 230 V AC 50/60 Hz (AC-3), 11 kW at 400 V AC 50/60 Hz (AC-4) |
IP Degree Of Protection | IP2X IEC 60529, IP2X VDE 0106 |
Compatibility Code | LC1D |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for control circuit, 80 A (at 140°F (60°C)) for power circuit |
Mechanical Robustness | Shocks contactor opened 10 Gn for 11 ms), Shocks contactor closed 15 Gn for 11 ms), Vibrations contactor opened 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz) |
Climatic Withstand | IACS E10 exposure to damp heat |
Minimum Switching Current | 5 mA for control circuit |
IRMS Rated Making Capacity | 140 A AC for control circuit conforming to IEC 60947-5-1, 900 A at 440 V for power circuit conforming to IEC 60947 |
Product Or Component Type | Contactor |
Control Circuit Type | AC 50/60 Hz |
Average Impedance | 1.5 mOhm - Ith 80 A 50 Hz for power circuit |
Insulation Resistance | Greater than 10 MOhm for control circuit |
Rated Insulation Voltage | Control circuit 600 V CSA, Control circuit 600 V UL, Power circuit 600 V CSA, Power circuit 600 V UL, Control circuit 690 V IEC 60947-1, Power circuit 690 V IEC 60947-1 |
Connections - Terminals | Control circuit: screw clamp terminal 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminal 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminal 1 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminal 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminal 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminal 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Power circuit: connector 1 0.00 to 0.05 in? (2.5 to 35 mm?) - cable stiffness: solid with cable end, Power circuit: connector 2 0.00 to 0.05 in? (2.5 to 35 mm?) - cable stiffness: solid with cable end, Power circuit: connector 1 0.00 to 0.05 in? (2.5 to 35 mm?) - cable stiffness: flexible without cable end, Power circuit: connector 2 0.00 to 0.04 in? (2.5 to 25 mm?) - cable stiffness: flexible without cable end, Power circuit: connector 1 0.00 to 0.05 in? (2.5 to 35 mm?) - cable stiffness: flexible with cable end, Power circuit: connector 2 0.00 to 0.05 in? (2.5 to 35 mm?) - cable stiffness: flexible with cable end |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Flame Retardance | V1 conforming to UL 94 |
Inrush Power in VA | 140 VA cos phi 0.75 (at 68°F (20°C)), 160 VA cos phi 0.75 (at 68°F (20°C)) |
Contactor Application | Motor control, Resistive load |
Hold-In Power Consumption in VA | 13 VA 50 Hz cos phi 0.3 (at 68°F (20°C)), 15 VA 60 Hz cos phi 0.3 (at 68°F (20°C)) |
Auxiliary Contact Composition | 1 NO + 1 NC |
Permissible Ambient Air Temperature Around The Device | 23 to 140°F (-5 to 60°C), -40 to 158°F (-40 to 70°C) at Uc |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Auxiliary Contacts Type | Mirror contact 1 NC IEC 60947-4-1, Mechanically linked 1 NO + 1 NC IEC 60947-5-1 |
Product Certifications | GOST, LROS (pending), UL, CCC, RINA, CSA, BV, GL, DNV, UKCA |
Rated Operational Current | 80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
Poles Description | 3P |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz |
Protective Cover | With |
Operating Altitude | 9842.52 ft (3000 m) without derating |
Mounting Support | Plate, Rail |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Minimum Switching Voltage | 17 V for control circuit |
Power Dissipation Per Pole | 3.7 W AC-3, 9.6 W AC-1, 3.7 W AC-3e |
Associated Fuse Rating | 10 A gG for control circuit conforming to IEC 60947-5-1, 100 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 100 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Utilisation Category | AC-3, AC-2, AC-4, AC-1, AC-3e |
Heat Dissipation | 4 to 5 W at 50/60 Hz for control circuit |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Coil Technology | Without built-in bidirectional peak limiting diode suppressor |
Control Circuit Voltage | 120 V AC 50/60 Hz |
Country of Origin (subject to change) | Czechia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 120 V AC, 50 A, SCHNEIDER ELECTRIC, Mfr# LC1D50G7
-$12.93 / ea
with subscription
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 3, Full Load Current - Inductive 150 A, Full Load Current - Resistive 200 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Series TeSys Deca, Number of Auxillary Contacts 3, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 15 hp