Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 40 A |
Action | Non-Reversing |
Full Load Amps-Resistive | 60 A |
Number of Poles | 3 |
Coil Volts | 480 V AC |
Reversing | No |
HP @ 1 Phase - 120V | 3 hp |
HP @ 1 Phase - 230V | 5 |
HP @ 1 Phase - 240V | 5 hp |
Height | 2.17 in |
Width | 2.17 in |
HP @ 3 Phase - 208V | 10 hp |
Depth | 4.61 in |
HP @ 3 Phase - 240V | 10 hp |
HP @ 3 Phase - 575V | 30 hp |
HP @ 3 Phase - 480V | 30 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Auxiliary Contact Form | 1NO/1NC |
Standards | CCC, CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, UL Listed |
Includes | Everlink Power Connections |
NEMA Size | Not Applicable |
Series | TeSys Deca |
Operating Speed | 3600 cycles per hr |
Rated Breaking Capacity | 800 A @ 440V |
Shock Resistance | 10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 800 A @ 440V (Power Circuit) |
Switching Voltage | 17 V (Signalling Circuit) |
Fuse Amps | 10 A (Signalling Circuit), 80 A (Type 1 Power Circuit), 80 A (Type 2 Power Circuit) |
Impulse Withstand Voltage | 6 kV |
Mounts On | Plate, Rail |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Net Weight | 0.85 kg |
Electrical Connection | Control Circuit: Screw Clamp Terminals, Power Circuit: EverLink BTR Screw Connectors |
Includes Protective Cover | Yes |
Tightening Torque | 1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit) |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 60 Hz) , Operational AC: 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 60 Hz) |
Working Height | Up to 9842.52 ft |
Overvoltage Category | CAT III |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Non-Overlap Time | 1.5 ms |
Hold VA | 13 VA |
Max. Operating Watts | 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 415 to 440V AC 50/60 Hz AC-3), 22 kW (at 500V AC 50/60 Hz AC-3), 30 kW (at 660 to 690V AC 50/60 Hz AC-3), 9 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 415 to 440V AC 50/60 Hz AC-3e), 22 kW (at 500V AC 50/60 Hz AC-3e), 30 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Features | Without Built-In Suppressor Module |
Inrush VA | 140 VA |
IP Rating | IP20 |
Mechanical Durability | 6 Mcycles |
Fire Rating | UL 94 V1 |
Application | Motor Control, Resistive Load |
Operating Time | 4 to 19 ms (Opening), 12 to 26 ms (Closing) |
Rated Voltage | 690V AC, 300V DC |
Electrical Durability | 1.4 Mcycles (60 A, AC-1, Less than 440 V), 1.5 Mcycles (40 A, AC-3, Less than 440 V), 1.5 Mcycles (40 A, AC-3e, Less than 440 V) |
Rated Insulation Volts | 600/690V |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 60 A (at 60°C Power Circuit) |
Watts Loss | 4 to 5W |
Impedance | 1.5 mOhm |
Max. Temperature | 850°C |
Signalling Circuit Frequency | 25 to 400 Hz |
Rated Short-Time Withstand Current | 320 A (at 40°C for 10 s Power Circuit), 720 A (at 40°C for 1 s Power Circuit), 72 A (at 40°C for 10 min Power Circuit), 165 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Switching Current | 5 mA (Signalling Circuit) |
Full Load Current - Inductive | 40 A |
Contactor Style | IEC |
Coil Voltage | 480V AC |
Maximum Operating Temperature | 140 Degrees F |
Number of Normally Open Main Contacts | 3 |
Resistance Properties | Fire Resistant, Insulation Resistant |
Horsepower @ Three Phase - 208V AC | 10 hp |
Maximum Voltage Rating | 690V AC |
Number of Auxillary Contacts | 2 |
Frequency | 50/60 Hz |
Full Load Current - Resistive | 60 A |
Horsepower @ Three Phase - 480V AC | 30 hp |
Horsepower @ Single Phase - 120V AC | 3 hp |
Phase | Three |
Minimum Operating Temperature | -40 Degrees F |
NEMA Enclosure Material | Not Applicable |
Terminal Connection Type | Screw Clamp Terminals |
Horsepower @ Three Phase - 240V AC | 10 hp |
Includes Auxiliary Contacts | Yes |
Embedded Surge Suppressor | No |
Reversing Capability | Non-Reversing |
Overall Height | 4.8 in |
Mounting Style | DIN Rail, Plate |
Overall Width | 2.17 in |
Electrical Operating Durability | 1,400,000, 1,500,000 |
NEMA Enclosure Rating | No Enclosure |
Overall Depth | 4.72 in |
Horsepower @ Three Phase - 600V AC | 30 hp |
Mechanical Operating Durability | 6,000,000 |
Horsepower @ Single Phase - 240V AC | 5 hp |
Country of Origin (subject to change) | Multiple |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 480 V AC, 40 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D40AT7
-$7.74 / ea
with subscription
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 480V AC, Number of Poles 3, Full Load Current - Inductive 40 A, Full Load Current - Resistive 60 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$257.99
You must be logged in to post a review.
Reviews