Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 9 A |
Number of Poles | 4 |
Coil Volts | 120 V AC |
Height | 85 mm |
Width | 45 mm |
Depth | 92 mm |
Aux. Contact Configuration | 1NO/1NC |
Standards | CSA C22.2 No 60947-4-1, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-5-1, GB/T 14048.4, UL, CCC, CSA, UKCA, EAC, CB, EU-RO-MR by DNV-GL, THIEC 60068-2-30 |
Series | LC1D |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Impedance | 2.5 mOhm |
Electrical Connection | Screw Clamp Terminals |
Operating Speed | 3600 cycles per hr |
Net Weight | 0.365 kg |
IP Rating | IP20 |
Rated Breaking Capacity | 250 A @ 440V |
Tightening Torque | 1.7 Nm |
Thermal Amperage | 20 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit) |
Switching Voltage | 17 V (Signalling Circuit) |
Application | Resistive Load |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Max. Temperature | 850°C |
Working Height | Up to 9842.52 ft |
Inrush VA | 70 VA |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Mounts On | Plate, Rail |
Mechanical Durability | 15 Mcycles |
Watts Loss | 2 to 3W |
Signalling Circuit Frequency | 25 to 400 Hz |
Includes Protective Cover | Yes |
Non-Overlap Time | 1.5 ms |
Rated Making Capacity | 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Rated Voltage | 690V AC, 250V DC |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Features | Without Built-In Suppressor Module |
Electrical Durability | 0.3 Mcycles (20 A, AC-1, Less than 690 V) |
Rated Insulation Volts | 600/690V |
Overvoltage Category | CAT III |
Fuse Amps | 10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit) |
Switching Current | 5 mA (Signalling Circuit) |
Impulse Withstand Voltage | 6 kV |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 60°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz) |
Rated Short-Time Withstand Current | 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Fire Rating | UL 94 V1 |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 4 Poles, 120 V AC, 9 A, SCHNEIDER ELECTRIC, Mfr# LC1D098G7
$135,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor
9999 in stock
Must order in multiples of 1
Subtotal:
$135.99