Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 150 A |
Full Load Amps-Resistive | 200 A |
Number of Poles | 3 |
Coil Volts | 110 V AC |
Height | 158 mm |
HP @ 3 Phase - 208V | 40 hp |
Width | 120 mm |
HP @ 3 Phase - 575V | 125 hp |
HP @ 3 Phase - 240V | 50 hp |
Depth | 136 mm |
HP @ 3 Phase - 480V | 100 hp |
Aux. Contact Configuration | 1NO/1NC |
Standards | CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, CCC, GOST, DNV, UL, LROS, BV, GL, RINA, CSA, UKCA, CE, THIEC 60068-2-30 |
Series | LC1D |
Rated Breaking Capacity | 1400 A @ 440V |
Environmental Attributes | Mercury Free, PVC Free, Pollution Degree 3 |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Operating Time | 20 to 35 ms (Closing), 40 to 75 ms (Opening) |
Features | Built-In Bi-Directional Peak Limiting Diode Suppressor |
Max. Operating Watts | 40 kW (at 220 to 230V AC 50/60 Hz AC-3), 75 kW (at 380 to 400V AC 50/60 Hz AC-3), 80 kW 415 to (at 440V AC 50/60 Hz AC-3), 90 kW (at 500V AC 50/60 Hz AC-3), 100 kW (at 660 to 690V AC 50/60 Hz AC-3), 75 kW (at 1000V AC 50/60 Hz AC-3), 22 kW (at 400V AC 50/60 Hz AC-4), 40 kW (at 220 to 230V AC 50/60 Hz AC-3e), 75 kW (at 380 to 400V AC 50/60 Hz AC-3e), 80 kW (at 415 to 440V AC 50/60 Hz AC-3e), 90 kW (at 500V AC 50/60 Hz AC-3e), 100 kW (at 660 to 690V AC 50/60 Hz AC-3e), 75 kW (at 1000V AC 50/60 Hz AC-3e) |
Electrical Connection | Screw Clamp Terminals |
Includes Protective Cover | Yes |
Hold VA | 2 to 18 VA |
Fuse Amps | 10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit) |
Overvoltage Category | CAT III |
Fire Rating | UL 94 V1 |
Operating Speed | 1200 cycles per hr |
Watts Loss | 3 to 4.5W |
Max. Temperature | 850°C |
Working Height | Up to 9842.52 ft |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Application | Motor Control, Resistive Load |
Inrush VA | 280 to 350 VA |
IP Rating | IP20 |
Electrical Durability | 0.85 Mcycles (150 A, AC-3, Less than 440 V), 1 Mcycles (200 A, AC-1, Less than 440 V), 0.85 Mcycles (150 A, AC-3e, Less than 440 V) |
Signalling Circuit Frequency | 25 to 400 Hz |
Switching Voltage | 17 V (Signalling Circuit) |
Mechanical Durability | 8 Mcycles |
Tightening Torque | 1.2 Nm (Control Circuit), 12 Nm (Power Circuit) |
Impedance | 0.6 mOhm |
Rated Insulation Volts | 600/1000V (Power Circuit), 600/690V (Signalling Circuit) |
Rated Voltage | 1000V AC, 300V DC |
Impulse Withstand Voltage | 8 kV |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1660 A @ 440V (Power Circuit) |
Non-Overlap Time | 1.5 ms |
Thermal Amperage | 200 A (at 60°C Power Circuit) |
Switching Current | 5 mA (Signalling Circuit) |
Net Weight | 2.5 kg |
Mounts On | Plate, Rail |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open) |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz) |
Rated Short-Time Withstand Current | 250 A (at 40°C for 10 min Power Circuit), 580 A (at 40°C for 1 min Power Circuit), 1200 A (at 40°C for 10 s Power Circuit), 1400 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Control Circuit Type | AC 50/60 Hz standard |
Rated Insulation Voltage | Power circuit 600 V CSA, Power circuit 600 V UL, Power circuit 1000 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL |
Control Circuit Voltage | 110 V AC 50/60 Hz |
Maximum Horse Power Rating | 40 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 50 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 100 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 125 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
Hold-In Power Consumption in VA | 2 to 18 VA 60 Hz cos phi 0.9 (at 68°F (20°C)), 2 to 18 VA 50 Hz cos phi 0.9 (at 68°F (20°C)) |
Permissible Ambient Air Temperature Around The Device | -40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating |
Rated Operational Voltage | Power circuit Less than or Equal to 1000 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC |
Product Or Component Type | Contactor |
Mounting Support | Plate, Rail |
Protective Cover | With |
Maximum Operating Rate | 1200 cyc/h 140°F (60°C) |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1, 315 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 250 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Climatic Withstand | IACS E10 exposure to damp heat |
Contact Compatibility | M13 |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Minimum Switching Voltage | 17 V for signalling circuit |
Flame Retardance | V1 conforming to UL 94 |
Rated Impulse Withstand Voltage | 8 kV IEC 60947 |
Pole Contact Composition | 3 NO |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
Heat Dissipation | 3 to 4.5 W at 50/60 Hz |
Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 6 Gn for 11 ms) |
Average Impedance | 0.6 mOhm - Ith 200 A 50 Hz for power circuit |
Product Certifications | CCC, GOST, DNV, UL, LROS (Lloyds register of shipping), BV, GL, RINA, CSA, UKCA, CE |
IRMS Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1660 A at 440 V for power circuit conforming to IEC 60947 |
Pollution Degree | 3 |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Coil Technology | Built-in bidirectional peak limiting diode suppressor |
Rated Operational Current | 200 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
IP Degree Of Protection | IP20 front face IEC 60529 |
Poles Description | 3P |
Utilisation Category | AC-4, AC-3, AC-1, AC-3e |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Rated Short Time Withstand Current | 250 A 104°F (40°C) - 10 min for power circuit, 580 A 104°F (40°C) - 1 min for power circuit, 1200 A 104°F (40°C) - 10 s for power circuit, 1400 A 104°F (40°C) - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
Auxiliary Contact Composition | 1 NO + 1 NC |
Motor Power KW | 40 kW at 220 to 230 V AC 50/60 Hz (AC-3), 75 kW at 380 to 400 V AC 50/60 Hz (AC-3), 80 kW at 415 to 440 V AC 50/60 Hz (AC-3), 90 kW at 500 V AC 50/60 Hz (AC-3), 100 kW at 660 to 690 V AC 50/60 Hz (AC-3), 75 kW at 1000 V AC 50/60 Hz (AC-3), 22 kW at 400 V AC 50/60 Hz (AC-4), 40 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 75 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 80 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 90 kW at 500 V AC 50/60 Hz (AC-3e), 100 kW at 660 to 690 V AC 50/60 Hz (AC-3e), 75 kW at 1000 V AC 50/60 Hz (AC-3e) |
Conventional Free Air Thermal Current | 200 A (at 140°F (60°C)) for power circuit |
Inrush Power in VA | 280 to 350 VA 60 Hz cos phi 0.9 (at 68°F (20°C)), 280 to 350 VA 50 Hz cos phi 0.9 (at 68°F (20°C)) |
Contactor Application | Motor control, Resistive load |
Safety Reliability Level | B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1, B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Minimum Switching Current | 5 mA for signalling circuit |
Connections - Terminals | Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: solid without cable end, Power circuit: connector 1 0.02 to 0.19 in? (10 to 120 mm?) - cable stiffness: flexible without cable end, Power circuit: connector 2 0.02 to 0.08 in? (10 to 50 mm?) - cable stiffness: flexible without cable end, Power circuit: connector 1 0.02 to 0.19 in? (10 to 120 mm?) - cable stiffness: flexible with cable end, Power circuit: connector 2 0.02 to 0.08 in? (10 to 50 mm?) - cable stiffness: flexible with cable end, Power circuit: connector 1 0.02 to 0.19 in? (10 to 120 mm?) - cable stiffness: solid without cable end, Power circuit: connector 2 0.02 to 0.08 in? (10 to 50 mm?) - cable stiffness: solid without cable end |
Protective Treatment | THIEC 60068-2-30 |
Power Dissipation Per Pole | 24 W AC-1, 13.5 W AC-3, 13.5 W AC-3e |
Country of Origin (subject to change) | Czechia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 110 V AC, 150 A, SCHNEIDER ELECTRIC, Mfr# LC1D150F7
$680,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor
9999 in stock
Must order in multiples of 1
Subtotal:
$680.99
You must be logged in to post a review.
Reviews
There are no reviews yet.