Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 40 A |
Number of Poles | 4 |
Coil Volts | 110 V AC |
Height | 91 mm |
Width | 45 mm |
Depth | 99 mm |
Aux. Contact Configuration | 1NO/1NC |
Standards | CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, CSA, GL, BV, RINA, DNV, UL, GOST, LROS, CCC, THIEC 60068-2-30 |
Series | LC1D |
Impedance | 2 mOhm |
Net Weight | 0.425 kg |
Switching Voltage | 17 V (Signalling Circuit) |
Tightening Torque | 1.7 Nm (Control Circuit), 1.8 Nm (Power Circuit) |
Rated Breaking Capacity | 450 A @ 440V |
IP Rating | IP20 |
Application | Resistive Load |
Rated Short-Time Withstand Current | 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Includes Protective Cover | Yes |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit) |
Switching Current | 5 mA (Signalling Circuit) |
Impulse Withstand Voltage | 6 kV |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Electrical Connection | Screw Clamp Terminals |
Mechanical Durability | 15 Mcycles |
Operating Time | 4 to 19 ms (Opening), 12 to 22 ms (Closing) |
Fuse Amps | 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit) |
Max. Temperature | 850°C |
Working Height | Up to 9842.52 ft |
Non-Overlap Time | 1.5 ms |
Electrical Durability | 1.4 Mcycles (40 A, AC-1, Less than 440 V) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Shock Resistance | 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
Rated Insulation Volts | 600/690V |
Overvoltage Category | CAT III |
Features | Without Built-In Suppressor Module |
Watts Loss | 2 to 3W |
Rated Voltage | 690V AC, 300V DC |
Signalling Circuit Frequency | 25 to 400 Hz |
Fire Rating | UL 94 V1 |
Mounts On | Plate, Rail |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Inrush VA | 70 VA |
Operating Speed | 3600 cycles per hr |
Pollution Degree | 3 |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Permissible Ambient Air Temperature Around The Device | -40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating |
Heat Dissipation | 2 to 3 W at 50/60 Hz |
Control Circuit Voltage | 110 V AC 50/60 Hz |
Rated Insulation Voltage | Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL, Power circuit 690 V IEC 60947-4-1 |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Contact Compatibility | M6 |
Product Certifications | CSA, GL, BV, RINA, DNV, UL, GOST, LROS (Lloyds register of shipping), CCC |
Product Or Component Type | Contactor |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit, 40 A (at 140°F (60°C)) for power circuit |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Utilisation Category | AC-1, AC-3, AC-3e, AC-4 |
Power Dissipation Per Pole | 3.2 W AC-1 |
IRMS Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947 |
Auxiliary Contact Composition | 1 NO + 1 NC |
Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 8 Gn for 11 ms) |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
IP Degree Of Protection | IP20 front face IEC 60529 |
Protective Cover | With |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Average Impedance | 2 mOhm - Ith 40 A 50 Hz for power circuit |
Mounting Support | Rail, Plate |
Poles Description | 4P |
Rated Operational Current | 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit |
Control Circuit Type | AC 50/60 Hz |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
Minimum Switching Voltage | 17 V for signalling circuit |
Protective Treatment | THIEC 60068-2-30 |
Minimum Switching Current | 5 mA for signalling circuit |
Pole Contact Composition | 4 NO |
Rated Short Time Withstand Current | 50 A 104°F (40°C) - 10 min for power circuit, 120 A 104°F (40°C) - 1 min for power circuit, 240 A 104°F (40°C) - 10 s for power circuit, 380 A 104°F (40°C) - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC |
Flame Retardance | V1 conforming to UL 94 |
Inrush Power in VA | 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
Connections - Terminals | Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 16 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 16 mm?) - cable stiffness: solid without cable end |
Hold-In Power Consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C)) |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 40 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Country of Origin (subject to change) | Multiple |
Package Quantity | 1 |
IEC Magnetic Contactor, 4 Poles, 110 V AC, 40 A, SCHNEIDER ELECTRIC, Mfr# LC1DT40F7
$225,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor
9999 in stock
Must order in multiples of 1
Subtotal:
$225.99
You must be logged in to post a review.
Reviews
There are no reviews yet.