Full Load Amps-Inductive | 50 A |
Item | IEC Magnetic Contactor |
Full Load Amps-Resistive | 80 A |
Number of Poles | 3 |
Coil Volts | 110 V AC |
Height | 127 mm |
HP @ 1 Phase - 240V | 7 1/2 hp |
HP @ 3 Phase - 208V | 15 hp |
Width | 85 mm |
HP @ 3 Phase - 575V | 40 hp |
Depth | 176 mm |
HP @ 3 Phase - 240V | 15 hp |
HP @ 3 Phase - 480V | 40 hp |
Aux. Contact Configuration | 1NO/1NC |
Series | LC1D |
Standards | CSA C22.2 No 14, IEC 60947-4-1, IEC 60947-5-1, EN 60947-5-1, EN 60947-4-1, GL, LROS, RINA, CCC, BV, DNV, GOST, CSA, UKCA |
Application | Motor Control, Resistive Load |
Features | Built-In Bi-Directional Peak Limiting Diode Suppressor |
Max. Operating Watts | 25 kW (at 415V AC 50 Hz AC-3), 30 kW (at 440V AC 50 Hz AC-3), 30 kW (at 500V AC 50 Hz AC-3), 33 kW (at 660 to 690V AC 50 Hz AC-3), 15 kW (at 220 to 230V AC 50 Hz AC-3), 11 kW (at 400V AC 50 Hz AC-4), 30 kW (at 1000V AC 50 Hz AC-3), 22 kW (at 380 to 400V AC 50 Hz AC-3e), 25 kW (at 415V AC 50 Hz AC-3e), 30 kW (at 440V AC 50 Hz AC-3e), 30 kW (at 500V AC 50 Hz AC-3e), 33 kW (at 660 to 690V AC 50 Hz AC-3e), 15 kW (at 220 to 230V AC 50 Hz AC-3e), 30 kW (at 1000V AC 50 Hz AC-3e), 25 kW (at 415V AC 50 Hz), 22 kW (at 380 to 400V AC 50 Hz) |
Control Circuit Voltage Limits | Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz), Operational DC: 0.75 to 1.25 Uc (at -40 to 60°C), Drop-Out DC: 0.1 to 0.3 Uc (at -40 to 70°C) |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Electrical Connection | Screw Clamp Terminals |
Inrush VA | 160 VA |
Non-Overlap Time | 1.5 ms |
Includes Protective Cover | Yes |
Rated Insulation Volts | 600/690V |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free |
Hold VA | 15 VA |
Rated Breaking Capacity | 900 A @ 440V |
Impulse Withstand Voltage | 8 kV |
Operating Speed | 3600 cycles per hr |
Tightening Torque | 1.7 Nm (Control Circuit), 5 Nm (Power Circuit) |
Operating Time | 12 to 26 ms (Closing), 20 ms (Opening) |
Rated Making Capacity | 140 A (AC Control Circuit), 900 A @ 440V (Power Circuit), 250 A (DC Control Circuit) |
Thermal Amperage | 80 A (at 60°C Power Circuit), 10 A (at 60°C Control Circuit) |
Max. Temperature | 850°C |
Mounts On | Plate, Rail |
Switching Current | 5 mA (Control Circuit) |
Net Weight | 2.185 kg |
Insulation Resistance Range | Greater Than 10 Mohms (Control Circuit) |
Working Height | Up to 9842.52 ft |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Fire Rating | UL 94 V1 |
Switching Voltage | 17 V (Control Circuit) |
Mechanical Durability | 10 Mcycles |
Rated Voltage | 690V AC |
Fuse Amps | 100 A (Type 1 and 2 Power Circuit), 10 A (Control Circuit) |
Overvoltage Category | CAT III |
IP Rating | IP2X |
Conventional Free Air Thermal Current | 80 A (at 140°F (60°C)) for power circuit, 10 A (at 140°F (60°C)) for control circuit |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Contactor Application | Resistive load, Motor control |
Control Circuit Type | DC standard |
Motor Power KW | 25 kW at 415 V AC 50 Hz (AC-3), 30 kW at 440 V AC 50 Hz (AC-3), 30 kW at 500 V AC 50 Hz (AC-3), 33 kW at 660 to 690 V AC 50 Hz (AC-3), 15 kW at 220 to 230 V AC 50 Hz (AC-3), 11 kW at 400 V AC 50 Hz (AC-4), 30 kW at 1000 V AC 50 Hz (AC-3), 22 kW at 380 to 400 V AC 50 Hz (AC-3e), 25 kW at 415 V AC 50 Hz (AC-3e), 30 kW at 440 V AC 50 Hz (AC-3e), 30 kW at 500 V AC 50 Hz (AC-3e), 33 kW at 660 to 690 V AC 50 Hz (AC-3e), 15 kW at 220 to 230 V AC 50 Hz (AC-3e), 30 kW at 1000 V AC 50 Hz (AC-3e), 25 kW at 415 V AC 50 Hz, 22 kW at 380 to 400 V AC 50 Hz |
Rated Insulation Voltage | Control circuit 600 V UL, Power circuit 600 V CSA, Power circuit 600 V UL IEC 60947-1, Control circuit 690 V IEC 60947-1, Power circuit 690 V CSA IEC 60947-1, Control circuit 600 V CSA |
Associated Fuse Rating | 100 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 100 A gG at Less than or Equal to 690 V coordination type 2 for power circuit conforming to IEC 60947-5-1, 10 A gG for control circuit conforming to IEC 60947-5-1 |
Product Certifications | GL, LROS (Lloyds register of shipping), RINA, CCC, BV, DNV, GOST, CSA, UKCA, GL |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz |
Pole Contact Composition | 3 NO |
Inrush Power in W | 19 W 68°F (20°C)) |
Hold-In Power Consumption in VA | 15 VA 50 Hz cos phi 0.3 (at 68°F (20°C)) |
Auxiliary Contacts Type | Mirror contact 1 NC IEC 60947-4-1, Mechanically linked 1 NO + 1 NC IEC 60947-5-1 |
Hold-In Power Consumption in W | 7.4 W 68°F (20°C) |
Flame Retardance | V1 conforming to UL 94 |
Poles Description | 3P |
Insulation Resistance | Greater than 10 MOhm for control circuit |
Time Constant | 34 ms |
Rated Operational Current | 80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit, 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit |
IP Degree Of Protection | IP2X VDE 0106, IP2X IEC 60529 |
Utilisation Category | AC-1, AC-4, AC-3, AC-3e, AC-1 |
Power Dissipation Per Pole | 9.6 W AC-1, 3.7 W AC-3e, 3.7 W AC-3 |
Maximum Horse Power Rating | 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors, 15 hp at 200/208 V AC 60 Hz for 3 phase motors, 15 hp at 230/240 V AC 60 Hz for 3 phase motors, 40 hp at 460/480 V AC 60 Hz for 3 phase motors, 40 hp at 575/600 V AC 60 Hz for 3 phase motors, 3 hp at 115 V AC 60 Hz for 1 phase motors |
Connections - Terminals | Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: rigid without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Power circuit: screw terminals 1 0.00 to 0.04 in? (2.5 to 25 mm?) - cable stiffness: rigid, Power circuit: screw terminals 2 0.00 to 0.02 in? (2.5 to 16 mm?) - cable stiffness: rigid without cable end, Power circuit: screw terminals 1 0.00 to 0.04 in? (2.5 to 25 mm?) - cable stiffness: flexible without cable end, Power circuit: screw terminals 2 0.00 to 0.02 in? (2.5 to 16 mm?) - cable stiffness: flexible without cable end, Power circuit: screw terminals 1 0.00 to 0.04 in? (2.5 to 25 mm?) - cable stiffness: flexible with cable end, Power circuit: screw terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: rigid, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: rigid |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Mounting Support | Rail, Rail |
Minimum Switching Current | 5 mA for control circuit |
Inrush Power in VA | 160 VA cos phi 0.75 (at 68°F (20°C)) |
Safety Reliability Level | B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 |
IRMS Rated Making Capacity | 140 A AC for control circuit conforming to IEC 60947-5-1, 900 A at 440 V for power circuit conforming to IEC 60947, 250 A DC for control circuit conforming to IEC 60947-5-1 |
Mechanical Robustness | Shocks contactor closed 15 Gn for 11 ms), Vibrations contactor opened 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor opened 10 Gn for 11 ms) |
Control Circuit Voltage | 110 V DC |
Protective Cover | With |
Minimum Switching Voltage | 17 V for control circuit |
Coil Technology | Built-in bidirectional peak limiting diode suppressor |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Auxiliary Contact Composition | 1 NO + 1 NC |
Climatic Withstand | IACS E10 exposure to damp heat |
Rated Impulse Withstand Voltage | 8 kV IEC 60947 |
Product Or Component Type | Contactor |
Country of Origin (subject to change) | Czechia |
Package Quantity | 1 |