Full Load Amps-Inductive | 95 A |
Item | IEC Magnetic Contactor |
Full Load Amps-Resistive | 125 A |
Number of Poles | 3 |
Coil Volts | 110 V AC |
Reversing | No |
HP @ 1 Phase - 120V | 7 1/2 hp |
Height | 5 in |
HP @ 1 Phase - 240V | 15 hp |
HP @ 3 Phase - 208V | 25 hp |
Width | 3.35 in |
HP @ 3 Phase - 240V | 30 hp |
HP @ 3 Phase - 575V | 60 hp |
Depth | 5.12 in |
HP @ 3 Phase - 480V | 60 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Frame / Series / Class / Code | TeSys |
NEMA Size | Not Applicable |
Series | TeSys Deca |
Standards | BV, CCC, CSA, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, DNV-GL, EAC, EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.4, IECEE CB Scheme, LROS, RINA, UL 60947-5-1, UL Listed, UL 60947-4-1 |
Auxiliary Contact Form | 1NO/1NC |
Electrical Connection | Screw Clamp Terminals |
Shock Resistance | 10 G for 11 ms (Contactor Closed), 8 G for 11 ms (Contactor Open) |
Signalling Circuit Frequency | 25 to 400 Hz |
Rated Short-Time Withstand Current | 1100 A (at 40°C for 1 s Power Circuit), 800 A (at 40°C for 10 s Power Circuit), 400 A (at 40°C for 1 min Power Circuit), 135 A (at 40°C for 10 min Power Circuit), 140 A (For 100 ms Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 100 A (For 1 s Signalling Circuit) |
IP Rating | IP20 |
Electrical Durability | 1.2 Mcycles (95 A AC-3, 1.3 Mcycles (125 A AC-1, 1.2 Mcycles (95 A AC-3e |
Max. Temperature | 850°C |
Switching Current | 5 mA (Signalling Circuit) |
Mechanical Durability | 4 Mcycles |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Features | Without Built-In Suppressor Module |
Rated Breaking Capacity | 1100 A @ 440V |
Operating Speed | 3600 cycles per hr |
Working Height | Up to 9842.52 ft |
Net Weight | 1.61 kg |
Max. Operating Watts | 25 kW (at 220 to 230V AC 50 Hz AC-3), 45 kW (at 380 to 400V AC 50 Hz AC-3), 45 kW (at 415 to 440V AC 50 Hz AC-3), 55 kW (at 500V AC 50 Hz AC-3), 45 kW (at 660 to 690V AC 50 Hz AC-3), 15 kW (at 400V AC 50 Hz AC-4), 25 kW (at 220 to 230V AC 50 Hz AC-3e), 45 kW (at 380 to 400V AC 50 Hz AC-3e), 45 kW (at 415 to 440V AC 50 Hz AC-3e), 55 kW (at 500V AC 50 Hz AC-3e), 45 kW (at 660 to 690V AC 50 Hz AC-3e) |
Impedance | 0.8 mOhm |
Rated Insulation Volts | 600/1000V (Power Circuit), 600/690V (Signalling Circuit) |
Fire Rating | UL 94 V1 |
Mounts On | Plate, Rail |
Control Circuit Voltage Limits | Operational AC: 0.8 to 1.1 Uc (at -40 to 55°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 55°C 60 Hz), 1 to 1.1 Uc (at 55 to 70°C 50/60 Hz), Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz) |
Rated Making Capacity | 1100 A @ 440V AC (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Fuse Amps | 10 A (Signalling Circuit), 200 A (Type 1 Power Circuit), 160 A (Type 2 Power Circuit) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Rated Voltage | 690V AC |
Overvoltage Category | CAT III |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 125 A (at 60°C Power Circuit) |
Switching Voltage | 17 V (Signalling Circuit) |
Tightening Torque | 1.2 Nm (Control Circuit), 12 Nm (Power Circuit) |
Non-Overlap Time | 1.5 ms |
Impulse Withstand Voltage | 8 kV |
Watts Loss | 6 to 10W |
Inrush VA | 245 VA |
Vibration Resistance | 3 G (Contactor Closed), 2 G (Contactor Open) |
Operating Time | 20 to 35 ms (Closing), 6 to 20 ms (Opening) |
Hold VA | 26 VA |
Includes Protective Cover | Yes |
Application | Motor Control, Resistive Load |
Terminal Connection Type | Screw Clamp Terminals |
Contactor Style | IEC |
Number of Normally Open Main Contacts | 3 |
Maximum Voltage Rating | 1000V AC |
Embedded Surge Suppressor | No |
Horsepower @ Three Phase - 600V AC | 60 hp |
Horsepower @ Three Phase - 208V AC | 30 hp |
Horsepower @ Three Phase - 240V AC | 30 hp |
Mounting Style | DIN Rail, Plate |
Resistance Properties | Fire Resistant, Insulation Resistant |
Mechanical Operating Durability | 4,000,000 |
Coil Voltage | 110V AC |
Reversing Capability | Non-Reversing |
Overall Width | 3.35 in |
Horsepower @ Single Phase - 240V AC | 15 hp |
Includes Auxiliary Contacts | Yes |
Full Load Current - Inductive | 95 A |
Overall Height | 5 in |
Number of Auxillary Contacts | 2 |
Horsepower @ Three Phase - 480V AC | 60 hp |
Maximum Operating Temperature | 140 Degrees F |
Phase | Three |
NEMA Enclosure Material | Not Applicable |
Full Load Current - Resistive | 125 A |
Frequency | 50/60 Hz |
Electrical Operating Durability | 1,200,000, 1,300,000 |
Overall Depth | 5.12 in |
Horsepower @ Single Phase - 120V AC | 7 1/2 hp |
NEMA Enclosure Rating | No Enclosure |
Minimum Operating Temperature | -40 Degrees F |
Country of Origin (subject to change) | Czechia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 110 V AC, 95 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D95F7
$434,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 110V AC, Number of Poles 3, Full Load Current - Inductive 95 A, Full Load Current - Resistive 125 A, Reversing Capability Non-Reversing, Overall Height 5 in, Overall Width 3.35 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal: