Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 40 A |
Full Load Amps-Resistive | 40 A |
Number of Poles | 4 |
Coil Volts | 120 V AC |
Reversing | No |
Height | 3.58 in |
Width | 1.77 in |
Depth | 3.9 in |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed |
Auxiliary Contact Form | 1NO/1NC |
NEMA Size | Not Applicable |
Series | TeSys Deca |
Frame / Series / Class / Code | TeSys |
Non-Overlap Time | 1.5 ms |
Rated Short-Time Withstand Current | 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Electrical Durability | 1.4 Mcycles (40 A, AC-1, Less than 440 V) |
Fuse Amps | 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit) |
IP Rating | IP20 |
Impedance | 2 mOhm |
Impulse Withstand Voltage | 6 kV |
Net Weight | 0.425 kg |
Mounts On | Plate, Rail |
Signalling Circuit Frequency | 25 to 400 Hz |
Operating Time | 4 to 19 ms (Opening), 12 to 22 ms (Closing) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Overvoltage Category | CAT III |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit) |
Mechanical Durability | 15 Mcycles |
Switching Voltage | 17 V (Signalling Circuit) |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit) |
Switching Current | 5 mA (Signalling Circuit) |
Shock Resistance | 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Rated Insulation Volts | 600/690V |
Inrush VA | 70 VA |
Rated Voltage | 690V AC, 300V DC |
Electrical Connection | Screw Clamp Terminals |
Includes Protective Cover | Yes |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Application | Resistive Load |
Max. Temperature | 850°C |
Tightening Torque | 1.7 Nm (Control Circuit), 1.8 Nm (Power Circuit) |
Operating Speed | 3600 cycles per hr |
Rated Breaking Capacity | 450 A @ 440V |
Features | Without Built-In Suppressor Module |
Working Height | Up to 9842.52 ft |
Watts Loss | 2 to 3W |
Fire Rating | UL 94 V1 |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Terminal Connection Type | Screw Clamp Terminals |
Mechanical Operating Durability | 15,000,000 |
Frequency | 50/60 Hz |
Overall Height | 3.58 in |
Embedded Surge Suppressor | No |
Number of Auxillary Contacts | 2 |
Overall Width | 1.77 in |
Mounting Style | DIN Rail, Plate |
Coil Voltage | 120V AC |
Reversing Capability | Non-Reversing |
Resistance Properties | Fire Resistant, Insulation Resistant |
Number of Normally Open Main Contacts | 4 |
NEMA Enclosure Rating | No Enclosure |
Minimum Operating Temperature | -40 Degrees F |
Electrical Operating Durability | 1,400,000 |
Contactor Style | IEC |
Maximum Operating Temperature | 140 Degrees F |
NEMA Enclosure Material | Not Applicable |
Maximum Voltage Rating | 690V AC |
Overall Depth | 3.9 in |
Full Load Current - Resistive | 40 A |
Includes Auxiliary Contacts | Yes |
Full Load Current - Inductive | 40 A |
Utilisation Category | AC-1, AC-3, AC-3e, AC-4 |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC |
Control Circuit Voltage | 120 V AC 50/60 Hz |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Product Certifications | DNV, GOST, BV, GL, CSA, UL, LROS (Lloyds register of shipping), RINA, CCC |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
Minimum Switching Voltage | 17 V for signalling circuit |
Rated Short Time Withstand Current | 50 A 104°F (40°C) - 10 min for power circuit, 120 A 104°F (40°C) - 1 min for power circuit, 240 A 104°F (40°C) - 10 s for power circuit, 380 A 104°F (40°C) - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 40 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Protective Treatment | THIEC 60068-2-30 |
IRMS Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947 |
Hold-In Power Consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C)) |
Inrush Power in VA | 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Rated Operational Current | 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Pollution Degree | 3 |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit, 40 A (at 140°F (60°C)) for power circuit |
IP Degree Of Protection | IP20 front face IEC 60529 |
Auxiliary Contact Composition | 1 NO + 1 NC |
Flame Retardance | V1 conforming to UL 94 |
Protective Cover | With |
Average Impedance | 2 mOhm - Ith 40 A 50 Hz for power circuit |
Compatibility Code | LC1D |
Power Dissipation Per Pole | 3.2 W AC-1 |
Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
Poles Description | 4P |
Permissible Ambient Air Temperature Around The Device | -40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating |
Control Circuit Type | AC 50/60 Hz |
Mounting Support | Rail, Plate |
Rated Insulation Voltage | Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL, Power circuit 690 V IEC 60947-4-1 |
Heat Dissipation | 2 to 3 W at 50/60 Hz |
Product Or Component Type | Contactor |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 8 Gn for 11 ms) |
Pole Contact Composition | 4 NO |
Contact Compatibility | M6 |
Minimum Switching Current | 5 mA for signalling circuit |
Connections - Terminals | Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 16 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 16 mm?) - cable stiffness: solid without cable end |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Country of Origin (subject to change) | Multiple |
Package Quantity | 1 |
IEC Magnetic Contactor, 4 Poles, 120 V AC, 40 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1DT40G7
-$6.99 / ea
with subscription
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 4, Full Load Current - Inductive 40 A, Full Load Current - Resistive 40 A, Reversing Capability Non-Reversing, Overall Height 3.58 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Maximum Voltage Rating 690V AC
9999 in stock
Must order in multiples of 1
Subtotal:
$232.99
You must be logged in to post a review.
Reviews
There are no reviews yet.