Full Load Amps-Inductive | 80 A |
Item | IEC Magnetic Contactor |
Full Load Amps-Resistive | 125 A |
Number of Poles | 3 |
Coil Volts | 120 V AC |
HP @ 1 Phase - 120V | 7 1/2 hp |
HP @ 1 Phase - 240V | 15 hp |
Height | 127 mm |
HP @ 3 Phase - 208V | 30 hp |
Width | 85 mm |
HP @ 3 Phase - 240V | 30 hp |
HP @ 3 Phase - 575V | 60 hp |
Depth | 130 mm |
HP @ 3 Phase - 480V | 60 hp |
Aux. Contact Configuration | 1NO/1NC |
Auxiliary Contact Form | 1NO/1NC |
NEMA Size | Not Applicable |
Series | TeSys Deca |
Standards | CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 |
Watts Loss | 6 to 10W |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Switching Voltage | 17 V (Signalling Circuit) |
Electrical Durability | 0.8 Mcycles (125 A, AC-1, Less than 440 V), 1.5 Mcycles (80 A, AC-3, Less than 440 V), 1.5 Mcycles (80 A, AC-3e, Less than 440 V) |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 125 A (at 60°C Power Circuit) |
Inrush VA | 220 VA |
Fuse Amps | 10 A (Signalling Circuit), 200 A (Type 1 Power Circuit), 160 A (Type 2 Power Circuit) |
Features | Without Built-In Suppressor Module |
Control Circuit Voltage Limits | Operational AC: 0.85 to 1.1 Uc (at -40 to 55°C 60 Hz), 1 to 1.1 Uc (at 55 to 70°C 60 Hz), Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 60 Hz) |
Rated Insulation Volts | 600/1000V (Power Circuit), 600/690V (Signalling Circuit) |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1100 A @ 440V (Power Circuit) |
Operating Time | 20 to 35 ms (Closing), 6 to 20 ms (Opening) |
Hold VA | 22 VA |
Vibration Resistance | 3 G (Contactor Closed), 2 G (Contactor Open) |
Impulse Withstand Voltage | 8 kV |
Operating Speed | 3600 cycles per hr |
Mounts On | Plate, Rail |
IP Rating | IP20 |
Working Height | Up to 9842.52 ft |
Non-Overlap Time | 1.5 ms |
Fire Rating | UL 94 V1 |
Electrical Connection | Screw Clamp Terminals |
Rated Short-Time Withstand Current | 640 A (at 40°C for 10 s Power Circuit), 990 A (at 40°C for 1 s Power Circuit), 135 A (at 40°C for 10 min Power Circuit), 320 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Mechanical Durability | 10 Mcycles |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Includes Protective Cover | Yes |
Tightening Torque | 1.2 Nm (Control Circuit), 12 Nm (Power Circuit) |
Application | Motor Control, Resistive Load |
Shock Resistance | 10 G for 11 ms (Contactor Closed), 8 G for 11 ms (Contactor Open) |
Switching Current | 5 mA (Signalling Circuit) |
Overvoltage Category | CAT III |
Signalling Circuit Frequency | 25 to 400 Hz |
Rated Voltage | 690V AC, 300V DC |
Impedance | 0.8 mOhm |
Max. Operating Watts | 22 kW (at 220 to 230V AC 50/60 Hz AC-3), 37 kW (at 380 to 400V AC 50/60 Hz AC-3), 45 kW (at 415 to 440V AC 50/60 Hz AC-3), 55 kW (at 500V AC 50/60 Hz AC-3), 45 kW (at 660 to 690V AC 50/60 Hz AC-3), 15 kW (at 400V AC 50/60 Hz AC-4), 22 kW (at 220 to 230V AC 50/60 Hz AC-3e), 37 kW (at 380 to 400V AC 50/60 Hz AC-3e), 45 kW (at 415 to 440V AC 50/60 Hz AC-3e), 55 kW (at 500V AC 50/60 Hz AC-3e), 45 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Max. Temperature | 850°C |
Net Weight | 1.59 kg |
Rated Breaking Capacity | 1100 A @ 440V |
Maximum Operating Temperature | 140 Degrees F |
Overall Height | 5 in |
Maximum Voltage Rating | 120V AC |
Full Load Current - Inductive | 150 A |
Horsepower @ Single Phase - 120V AC | 7 1/2 hp |
Horsepower @ Three Phase - 480V AC | 60 hp |
Reversing Capability | Non-Reversing |
Overall Depth | 5.12 in |
Terminal Connection Type | Screw Clamp Terminals |
Horsepower @ Three Phase - 240V AC | 30 hp |
Horsepower @ Three Phase - 208V AC | 30 hp |
Overall Width | 3.35 in |
Includes Auxiliary Contacts | Yes |
Mounting Style | DIN Rail |
Horsepower @ Three Phase - 600V AC | 60 hp |
Number of Normally Closed Main Contacts | 0 |
Mechanical Operating Durability | 10,000,000 |
Coil Voltage | 120V AC |
Contactor Style | IEC |
Full Load Current - Resistive | 200 A |
Number of Normally Open Main Contacts | 1 |
Horsepower @ Single Phase - 240V AC | 15 hp |
Frequency | 60 Hz |
Number of Auxillary Contacts | 3 |
NEMA Enclosure Rating | No Enclosure |
Embedded Surge Suppressor | No |
Phase | Three |
Minimum Operating Temperature | -40 Degrees F |
Electrical Operating Durability | 1,500,000 (80 A AC-3 Less Than= 440 V), 1,500,000 (80 A AC-3e Less Than= 440 V), 800,000 (125 A AC-1 Less Than= 440 V) |
Country of Origin (subject to change) | Czechia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 120 V AC, 80 A, SCHNEIDER ELECTRIC, Mfr# LC1D80G6
$401,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 3, Full Load Current - Inductive 150 A, Full Load Current - Resistive 200 A, Reversing Capability Non-Reversing, Overall Height 5 in, Overall Width 3.35 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Series TeSys Deca, Number of Auxillary Contacts 3, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 30 hp
9999 in stock
Must order in multiples of 1
Subtotal:
$401.99
You must be logged in to post a review.