IEC Magnetic Contactor, 3 Poles, 220 V AC, 40 A, SCHNEIDER ELECTRIC, Mfr# LC1D40AM7

$279,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Number of Poles 3

9999 in stock

Must order in multiples of 1
Subtotal:
$279.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D40AM7
Availability: Ships in 5 days
SKU: GRG0849646 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive40 A
Full Load Amps-Resistive60 A
Number of Poles3
Coil Volts220 V AC
HP @ 1 Phase - 240V5 hp
Height122 mm
HP @ 3 Phase - 208V10 hp
Width55 mm
HP @ 3 Phase - 575V30 hp
HP @ 3 Phase - 240V10 hp
Depth120 mm
HP @ 3 Phase - 480V30 hp
Aux. Contact Configuration1NO/1NC
SeriesLC1D
StandardsCSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, CCC, GOST, UL, CSA, THIEC 60068-2-30
IncludesEverlink Power Connections
FeaturesWithout Built-In Suppressor Module
ApplicationMotor Control, Resistive Load
Tightening Torque1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Net Weight0.85 kg
Fire RatingUL 94 V1
Overvoltage CategoryCAT III
Impedance1.5 mOhm
Includes Protective CoverYes
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Mechanical Durability6 Mcycles
Max. Operating Watts18.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 415 to 440V AC 50/60 Hz AC-3), 22 kW (at 500V AC 50/60 Hz AC-3), 30 kW (at 660 to 690V AC 50/60 Hz AC-3), 9 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 415 to 440V AC 50/60 Hz AC-3e), 22 kW (at 500V AC 50/60 Hz AC-3e), 30 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Shock Resistance10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Non-Overlap Time1.5 ms
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 800 A @ 440V (Power Circuit)
Electrical ConnectionControl Circuit: Screw Clamp Terminals, Power Circuit: EverLink BTR Screw Connectors
Fuse Amps10 A (Signalling Circuit), 80 A (Type 1 Power Circuit), 80 A (Type 2 Power Circuit)
Inrush VA140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C)
Watts Loss4 to 5W
IP RatingIP20
Signalling Circuit Frequency25 to 400 Hz
Rated Insulation Volts600/690V
Switching Voltage17 V (Signalling Circuit)
Electrical Durability1.4 Mcycles (60 A, AC-1, Less than 440 V), 1.5 Mcycles (40 A, AC-3, Less than 440 V), 1.5 Mcycles (40 A, AC-3e, Less than 440 V)
Impulse Withstand Voltage6 kV
Max. Temperature850°C
Operating Speed3600 cycles per hr
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Working HeightUp to 9842.52 ft
Thermal Amperage10 A (at 60°C Signalling Circuit), 60 A (at 60°C Power Circuit)
Rated Short-Time Withstand Current320 A (at 40°C for 10 s Power Circuit), 720 A (at 40°C for 1 s Power Circuit), 72 A (at 40°C for 10 min Power Circuit), 165 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Switching Current5 mA (Signalling Circuit)
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Operating Time4 to 19 ms (Opening), 12 to 26 ms (Closing)
Mounts OnPlate, Rail
Rated Voltage690V AC, 300V DC
Rated Breaking Capacity800 A @ 440V
Hold VA13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C)
Auxiliary Contact Composition1 NO + 1 NC
Connections - TerminalsControl circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: EverLink BTR screw connectors 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: flexible without cable end, Power circuit: EverLink BTR screw connectors 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: flexible without cable end, Power circuit: EverLink BTR screw connectors 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: flexible with cable end, Power circuit: EverLink BTR screw connectors 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: flexible with cable end, Power circuit: EverLink BTR screw connectors 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: solid without cable end, Power circuit: EverLink BTR screw connectors 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: solid without cable end
Minimum Switching Voltage17 V for signalling circuit
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Product CertificationsCCC, GOST, UL, CSA
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Flame RetardanceV1 conforming to UL 94
Average Impedance1.5 mOhm - Ith 60 A 50 Hz for power circuit
Motor Power KW18.5 kW at 380 to 400 V AC 50/60 Hz (AC-3), 11 kW at 220 to 230 V AC 50/60 Hz (AC-3), 22 kW at 415 to 440 V AC 50/60 Hz (AC-3), 22 kW at 500 V AC 50/60 Hz (AC-3), 30 kW at 660 to 690 V AC 50/60 Hz (AC-3), 9 kW at 400 V AC 50/60 Hz (AC-4), 18.5 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 11 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 22 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 22 kW at 500 V AC 50/60 Hz (AC-3e), 30 kW at 660 to 690 V AC 50/60 Hz (AC-3e)
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Protective TreatmentTHIEC 60068-2-30
Rated Insulation VoltagePower circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL, Power circuit 690 V IEC 60947-4-1
Control Circuit Voltage220 V AC 50/60 Hz
Hold-In Power Consumption in VA13 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 15 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Poles Description3P
Control Circuit TypeAC 50/60 Hz standard
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Minimum Switching Current5 mA for signalling circuit
Utilisation CategoryAC-4, AC-1, AC-3, AC-3e
Contact CompatibilityM2
Product Or Component TypeContactor
Heat Dissipation4 to 5 W at 50/60 Hz
Power Dissipation Per Pole2.4 W AC-3, 5.4 W AC-1, 2.4 W AC-3e
Mounting SupportPlate, Rail
Inrush Power in VA140 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 160 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Fire Resistance1562°F (850°C) IEC 60695-2-1
Protective CoverWith
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 60 A (at 140°F (60°C)) for power circuit
Maximum Horse Power Rating5 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 30 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 3 hp at 115 V AC 50/60 Hz for 1 phase motors, 30 hp at 460/480 V AC 50/60 Hz for 3 phase motors
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Rated Short Time Withstand Current320 A 104°F (40°C) - 10 s for power circuit, 720 A 104°F (40°C) - 1 s for power circuit, 72 A 104°F (40°C) - 10 min for power circuit, 165 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 800 A at 440 V for power circuit conforming to IEC 60947
Rated Impulse Withstand Voltage6 kV IEC 60947
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 10 Gn for 11 ms)
IP Degree Of ProtectionIP20 front face IEC 60529
Pollution Degree3
Rated Operational Current60 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 80 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 80 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Pole Contact Composition3 NO
Contactor ApplicationResistive load, Motor control
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Country of Origin (subject to change)Multiple
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#220 V AC
#40 A
#SCHNEIDER ELECTRIC
#Mfr LC1D40AM7
#SCHNEIDER ELECTRIC
#GRG0849646
#mfr:LC1D40AM7
#part number:LC1D40AM7
#pn:LC1D40AM7
#part code:LC1D40AM7
#item number:LC1D40AM7
#product code:LC1D40AM7
#manufacturer number:LC1D40AM7
#manufacturers part number:LC1D40AM7
#mfn:LC1D40AM7

Reviews

There are no reviews yet.

Add a review