Full Load Amps-Inductive | 25 A |
Item | IEC Magnetic Contactor |
Full Load Amps-Resistive | 40 A |
Number of Poles | 3 |
Coil Volts | 24 V DC |
HP @ 1 Phase - 240V | 3 hp |
Height | 85 mm |
HP @ 3 Phase - 208V | 7 1/2 hp |
Width | 45 mm |
HP @ 3 Phase - 240V | 7 1/2 hp |
Depth | 101 mm |
HP @ 3 Phase - 575V | 20 hp |
HP @ 3 Phase - 480V | 15 hp |
Aux. Contact Configuration | 1NO/1NC |
Series | LC1D |
Standards | CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, BV, UL, DNV, CSA, GL, GOST, LROS, CCC, RINA, UKCA, THIEC 60068-2-30 |
Application | Motor Control, Resistive Load |
Features | Built-In Bi-Directional Peak Limiting Diode Suppressor |
Rated Breaking Capacity | 450 A @ 440V |
Impulse Withstand Voltage | 6 kV |
Net Weight | 0.53 kg |
Shock Resistance | 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
Rated Insulation Volts | 600/690V |
Max. Temperature | 850°C |
Electrical Durability | 1.65 Mcycles (25 A, AC-3, Less than 440 V), 1.4 Mcycles (40 A, AC-1, Less than 440 V), 1.65 Mcycles (25 A, AC-3e, Less than 440 V) |
Working Height | Up to 9842.52 ft |
Mechanical Durability | 30 Mcycles |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Fuse Amps | 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit) |
Rated Voltage | 690V AC, 300V DC |
Control Circuit Voltage Limits | Drop-Out DC: 0.1 to 0.25 Uc (at -40 to 70°C), Operational DC: 0.7 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C) |
Environmental Attributes | Mercury Free, PVC Free, Pollution Degree 3 |
Max. Operating Watts | 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 11 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 415 to 440V AC 50/60 Hz AC-3), 15 kW (at 500V AC 50/60 Hz AC-3), 15 kW (at 660 to 690V AC 50/60 Hz AC-3), 5.5 kW (at 400V AC 50/60 Hz AC-4), 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 11 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 415 to 440V AC 50/60 Hz AC-3e), 15 kW (at 500V AC 50/60 Hz AC-3e), 15 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Tightening Torque | 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit) |
Non-Overlap Time | 1.5 ms |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Operating Speed | 3600 cycles per hr |
IP Rating | IP20 |
Switching Voltage | 17 V (Signalling Circuit) |
Impedance | 2 mOhm |
Signalling Circuit Frequency | 25 to 400 Hz |
Overvoltage Category | CAT III |
Rated Short-Time Withstand Current | 240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Fire Rating | UL 94 V1 |
Includes Protective Cover | Yes |
Mounts On | Plate, Rail |
Switching Current | 5 mA (Signalling Circuit) |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit) |
Operating Time | 53.55 to 72.45 ms (Closing), 16 to 24 ms (Opening) |
Electrical Connection | Lugs-Ring Terminals |
Pole Contact Composition | 3 NO |
Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 8 Gn for 11 ms) |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Poles Description | 3P |
Rated Operational Current | 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Protective Treatment | THIEC 60068-2-30 |
Coil Technology | Built-in bidirectional peak limiting diode suppressor |
Protective Cover | With |
Permissible Ambient Air Temperature Around The Device | -40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit, 40 A (at 140°F (60°C)) for power circuit |
Hold-In Power Consumption in W | 5.4 W 68°F (20°C) |
Power Dissipation Per Pole | 3.2 W AC-1, 1.25 W AC-3, 1.25 W AC-3e |
Pollution Degree | 3 |
Contact Compatibility | M4 |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Minimum Switching Current | 5 mA for signalling circuit |
IRMS Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947 |
Inrush Power in W | 5.4 W 68°F (20°C)) |
Connections - Terminals | Control circuit: lugs-ring terminals - external diameter: 0.31 in (8 mm), Power circuit: lugs-ring terminals - external diameter: 0.39 in (10 mm) |
Time Constant | 28 ms |
Mounting Support | Rail, Plate |
Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL |
Maximum Horse Power Rating | 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC |
Average Impedance | 2 mOhm - Ith 40 A 50 Hz for power circuit |
Product Certifications | BV, UL, DNV, CSA, GL, GOST, LROS (Lloyds register of shipping), CCC, RINA, UKCA |
Control Circuit Type | DC standard |
Auxiliary Contact Composition | 1 NO + 1 NC |
Minimum Switching Voltage | 17 V for signalling circuit |
IP Degree Of Protection | IP20 front face IEC 60529 |
Utilisation Category | AC-3, AC-1, AC-4, AC-3e |
Product Or Component Type | Contactor |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 40 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Rated Short Time Withstand Current | 240 A 104°F (40°C) - 10 s for power circuit, 380 A 104°F (40°C) - 1 s for power circuit, 50 A 104°F (40°C) - 10 min for power circuit, 120 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
Contactor Application | Motor control, Resistive load |
Flame Retardance | V1 conforming to UL 94 |
Motor Power KW | 5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3), 11 kW at 380 to 400 V AC 50/60 Hz (AC-3), 11 kW at 415 to 440 V AC 50/60 Hz (AC-3), 15 kW at 500 V AC 50/60 Hz (AC-3), 15 kW at 660 to 690 V AC 50/60 Hz (AC-3), 5.5 kW at 400 V AC 50/60 Hz (AC-4), 5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 11 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 11 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 15 kW at 500 V AC 50/60 Hz (AC-3e), 15 kW at 660 to 690 V AC 50/60 Hz (AC-3e) |
Country of Origin (subject to change) | Indonesia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 V DC, 25 A, SCHNEIDER ELECTRIC, Mfr# LC1D256BD
$196,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor
Out of stock
You must be logged in to post a review.
Reviews
There are no reviews yet.