IEC Magnetic Contactor, 3 Poles, 24 V DC, 32 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D32BL

$267,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 32 A, Full Load Current - Resistive 50 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$267.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D32BL
Availability: Ships in 5 days
SKU: GRG0569296 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive32 A
Full Load Amps-Resistive50 A
Number of Poles3
Coil Volts24 V DC
ReversingNo
HP @ 1 Phase - 120V2 hp
Height3.35 in
HP @ 1 Phase - 240V5 hp
Width1.77 in
HP @ 3 Phase - 208V7 1/2 hp
HP @ 3 Phase - 575V30 hp
HP @ 3 Phase - 240V10 hp
Depth3.96 in
HP @ 3 Phase - 480V20 hp
Enclosure NEMA RatingNo Enclosure
Aux. Contact Configuration1NO/1NC
Hz50/60
Frame / Series / Class / CodeTeSys
Auxiliary Contact Form1NO/1NC
NEMA SizeNot Applicable
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
SeriesTeSys Deca
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Thermal Amperage10 A (at 60°C Signalling Circuit), 50 A (at 60°C Power Circuit)
Net Weight0.535 kg
Signalling Circuit Frequency25 to 400 Hz
Impedance2 mOhm
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 550 A @ 440V (Power Circuit)
Fuse Amps10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 63 A (Type 2 Power Circuit)
Electrical Durability1.65 Mcycles (32 A, AC-3, Less than 440 V), 1.4 Mcycles (50 A, AC-1, Less than 440 V), 1.65 Mcycles (32 A, AC-3e, Less than 440 V)
Rated Breaking Capacity550 A @ 440V
IP RatingIP20
Overvoltage CategoryCAT III
Operating Time65.45 to 88.55 ms (Closing), 20 to 30 ms (Opening)
Max. Temperature850°C
Operating Speed3600 cycles per hr
Mechanical Durability30 Mcycles
Max. Operating Watts7.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 15 kW (at 380 to 400V AC 50/60 Hz AC-3), 15 kW (at 415 to 440V AC 50/60 Hz AC-3), 18.5 kW (at 500V AC 50/60 Hz AC-3), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 7.5 kW (at 400V AC 50/60 Hz AC-4), 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 15 kW (at 380 to 400V AC 50/60 Hz AC-3e), 15 kW (at 415 to 440V AC 50/60 Hz AC-3e), 18.5 kW (at 500V AC 50/60 Hz AC-3e), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Fire RatingUL 94 V1
Control Circuit Voltage LimitsDrop-Out DC: 0.1 to 0.3 Uc (at -40 to 70°C), Operational DC: 0.8 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C)
FeaturesBuilt-In Bi-Directional Peak Limiting Diode Suppressor
Rated Insulation Volts600/690V
Rated Voltage690V AC, 300V DC
Non-Overlap Time1.5 ms
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Switching Current5 mA (Signalling Circuit)
Electrical ConnectionScrew Clamp Terminals
Tightening Torque1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
Rated Short-Time Withstand Current260 A (at 40°C for 10 s Power Circuit), 430 A (at 40°C for 1 s Power Circuit), 60 A (at 40°C for 10 min Power Circuit), 138 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Impulse Withstand Voltage6 kV
Includes Protective CoverYes
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Mounts OnPlate, Rail
ApplicationMotor Control, Resistive Load
Working HeightUp to 9842.52 ft
Switching Voltage17 V (Signalling Circuit)
Shock Resistance8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Frequency50/60 Hz
Horsepower @ Single Phase - 120V AC2 hp
Overall Width1.77 in
Maximum Voltage Rating690V AC
Number of Normally Open Main Contacts3
NEMA Enclosure RatingNo Enclosure
Number of Auxillary Contacts2
Contactor StyleIEC
NEMA Enclosure MaterialNot Applicable
Maximum Operating Temperature140 Degrees F
Mounting StyleDIN Rail, Plate
Horsepower @ Three Phase - 480V AC20 hp
Minimum Operating Temperature-40 Degrees F
Coil Voltage24V DC
Horsepower @ Three Phase - 208V AC7 1/2 hp
Reversing CapabilityNon-Reversing
Overall Height3.35 in
PhaseThree
Full Load Current - Resistive50 A
Full Load Current - Inductive32 A
Electrical Operating Durability1,400,000, 1,650,000
Overall Depth3.98 in
Resistance PropertiesFire Resistant, Insulation Resistant
Mechanical Operating Durability30,000,000
Includes Auxiliary ContactsYes
Horsepower @ Three Phase - 240V AC10 hp
Embedded Surge SuppressorYes
Terminal Connection TypeScrew Clamp Terminals
Horsepower @ Single Phase - 240V AC5 hp
Horsepower @ Three Phase - 600V AC30 hp
Country of Origin (subject to change)Indonesia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#24 V DC
#32 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D32BL
#SCHNEIDER ELECTRIC
#GRG0569296
#mfr:LC1D32BL
#part number:LC1D32BL
#pn:LC1D32BL
#part code:LC1D32BL
#item number:LC1D32BL
#product code:LC1D32BL
#manufacturer number:LC1D32BL
#manufacturers part number:LC1D32BL
#mfn:LC1D32BL

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!