Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 6 A |
Number of Poles | 3 |
Coil Volts | 24 V DC |
Reversing | No |
Height | 2.28 in |
Width | 1.77 in |
Depth | 2.24 in |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | None |
Hz | 50/60 |
Frame / Series / Class / Code | TeSys |
Series | TeSys K |
Auxiliary Contact Form | 1NC |
NEMA Size | Not Applicable |
Standards | CCC, CSA, EAC, REACH, RoHS, UKCA, UL Listed |
Tightening Torque | 0.8 to 1.3 Nm |
Mechanical Durability | 10 Mcycles |
Rated Voltage | 690V AC |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Operating Time | 30 to 40 ms (Coil Energisation and NO Closing), 10 ms (Coil De-Energisation and NO Opening) |
Impedance | 3 mOhm |
Rated Making Capacity | 110 A |
Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
Rated Breaking Capacity | 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V |
Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.1 to 0.75 Uc (at 50°C) |
Switching Voltage | 17 V (Signalling Circuit) |
Electrical Durability | 1.3 Mcycles 6 A AC-3 Less than or Equal to 440 V, 1.3 Mcycles 6 A AC-3e Less than or Equal to 440 V, 0.05 Mcycles 36 A AC-4 Less than or Equal to 440 V |
Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
Thermal Amperage | 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit) |
Net Weight | 0.225 kg |
Mounts On | Plate, Rail |
Operating Speed | 3600 cycles per hr |
Overvoltage Category | CAT III |
Working Height | 6561.68 ft |
Impulse Withstand Voltage | 8 kV |
Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
Application | Motor Control |
Rated Insulation Volts | 600/690V |
Switching Current | 5 mA (Signalling Circuit) |
Includes Auxiliary Contacts | Yes |
Overall Width | 1.77 in |
Reversing Capability | Non-Reversing |
Contactor Style | IEC |
NEMA Enclosure Material | Not Applicable |
Number of Normally Open Main Contacts | 3 |
Minimum Operating Temperature | -13 Degrees F |
NEMA Enclosure Rating | No Enclosure |
Overall Height | 2.28 in |
Maximum Operating Temperature | 122 Degrees F |
Resistance Properties | Insulation Resistant |
Embedded Surge Suppressor | No |
Full Load Current - Inductive | 6 A |
Mechanical Operating Durability | 10,000,000 |
Terminal Connection Type | Screw Clamp Terminals |
Frequency | 50/60 Hz |
Mounting Style | DIN Rail, Plate |
Coil Voltage | 24V DC |
Number of Auxillary Contacts | 1 |
Maximum Voltage Rating | 690V AC |
Overall Depth | 2.24 in |
Power Pole Contact Composition | 3 NO |
Ambient Air Temperature For Storage | -58 to 176°F (-50 to 80°C) |
Operating Altitude | 6561.68 ft (2000 m) without derating |
Mounting Support | Rail, Plate |
Flame Retardance | V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102 |
Control Circuit Type | DC standard |
Ambient Air Temperature For Operation | -13 to 122°F (-25 to 50°C) |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Auxiliary Contacts Type | Instantaneous 1 NC |
Heat Dissipation | 1.3 W |
Auxiliary Contact Composition | 1 NC |
Hold-In Power Consumption in W | 3 W 68°F (20°C) |
Inrush Power in W | 3 W 68°F (20°C)) |
Product Or Component Type | Contactor |
Product Certifications | CB Scheme, CCC, UL, CSA, EAC, CE, UKCA |
Average Impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
Motor Power KW | 1.5 kW 220 to 230 V AC 50/60 Hz AC-3, 2.2 kW 380 to 415 V AC 50/60 Hz AC-3, 3 kW 440/690 V AC 50/60 Hz AC-3, 1.5 kW 220 to 230 V AC 50/60 Hz AC-3e, 2.2 kW 380 to 415 V AC 50/60 Hz AC-3e, 3 kW 440/690 V AC 50/60 Hz AC-3e, 1.5 kW 220 to 230 V AC 50/60 Hz AC-4, 2.2 kW 380 to 415 V AC 50/60 Hz AC-4, 3 kW 440/690 V AC 50/60 Hz AC-4 |
Poles Description | 3P |
Utilisation Category | AC-3, AC-3e, AC-4 |
Maximum Operating Rate | 3600 cyc/h |
Minimum Switching Current | 5 mA for signalling circuit |
Conventional Free Air Thermal Current | 20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit |
IRMS Rated Making Capacity | 110 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947 |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz, Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz |
Rated Short Time Withstand Current | 90 A 122°F (50°C) - 1 s for power circuit, 85 A 122°F (50°C) - 5 s for power circuit, 80 A 122°F (50°C) - 10 s for power circuit, 60 A 122°F (50°C) - 30 s for power circuit, 45 A 122°F (50°C) - 1 min for power circuit, 40 A 122°F (50°C) - 3 min for power circuit, 20 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit |
Rated Operational Current | 6 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 6 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
IP Degree Of Protection | IP2X |
Connections - Terminals | screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end, Power circuit screw clamp terminals 2 0.00 in? (1.5 mm?)flexible with cable end |
Rated Insulation Voltage | Power circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14 |
Associated Fuse Rating | 25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660 |
Minimum Switching Voltage | 17 V for signalling circuit |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 V DC, 6 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LP1K0601BD
-3% / ea
with subscription
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 6 A, Reversing Capability Non-Reversing, Overall Height 2.28 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC, Maximum Voltage Rating 690V AC, Embedded Surge Suppressor No
9999 in stock
Must order in multiples of 1
Subtotal:
$79.79
You must be logged in to post a review.
Reviews
There are no reviews yet.