Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 9 A |
Full Load Amps-Resistive | 20 A |
Number of Poles | 3 |
Coil Volts | 24 to 60 V AC/DC |
Reversing | No |
HP @ 1 Phase - 120V | 1/3 hp |
Height | 3.03 in |
HP @ 1 Phase - 240V | 1 hp |
Width | 1.77 in |
HP @ 3 Phase - 208V | 2 hp |
HP @ 3 Phase - 240V | 2 hp |
HP @ 3 Phase - 575V | 7 1/2 hp |
Depth | 3.38 in |
HP @ 3 Phase - 480V | 5 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Frame / Series / Class / Code | TeSys |
Standards | CCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1 |
NEMA Size | Not Applicable |
Auxiliary Contact Form | 1NO/1NC |
Series | TeSys Deca |
Operating Time | 45 to 55 ms (Closing), 20 to 90 ms (Opening) |
Electrical Connection | Screw Clamp Terminals |
Fire Rating | UL 94 V1 |
Includes Protective Cover | Yes |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Mechanical Durability | 15 Mcycles |
Mounts On | Plate, Rail |
Overvoltage Category | CAT III |
Electrical Durability | 2.4 Mcycles (8 A, AC-3, Less than 440 V), 0.6 Mcycles (25 A, AC-1, Less than 440 V), 2.4 Mcycles (8 A, AC-3e, Less than 440 V) |
Application | Motor Control, Resistive Load |
Watts Loss | 0.6W |
Rated Short-Time Withstand Current | 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit) |
Operating Speed | 3600 cycles per hr |
Rated Insulation Volts | 690V |
Switching Voltage | 17 V (Signalling Circuit) |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit) |
IP Rating | IP20 |
Non-Overlap Time | 1.5 ms |
Switching Current | 5 mA (Signalling Circuit) |
Working Height | Up to 9842.52 ft |
Signalling Circuit Frequency | 25 to 400 Hz |
Rated Making Capacity | 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Fuse Amps | 10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit) |
Impedance | 2.5 mOhm |
Rated Voltage | 690V AC |
Control Circuit Voltage Limits | Drop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C), Operational AC: 0.85 to 1.1 Uc (at -40 to 60°C), Operational DC: 0.8 to 1.1 Uc (at -40 to 60°C), Operational AC/DC 1 to 1.1 Uc (at 60 to 70°C) |
Tightening Torque | 1.7 Nm |
Hold VA | 0.9 VA |
Inrush VA | 15 VA |
Impulse Withstand Voltage | 6 kV |
Features | Built-In Bi-Directional Peak Limiting |
Net Weight | 0.368 kg |
Max. Operating Watts | 2.2 kW (at 220 to 230V AC 50 Hz AC-3), 4 kW (at 380 to 400V AC 50 Hz AC-3), 4 kW (at 415V AC 50 Hz AC-3), 4 kW (at 440V AC 50 Hz AC-3), 5.5 kW (at 500V AC 50 Hz AC-3), 5.5 kW (at 660 to 690V AC 50 Hz AC-3), 2.2 kW (at 220 to 230V AC 50 Hz AC-3e), 4 kW (at 380 to 400V AC 50 Hz AC-3e), 4 kW (at 415V AC 50 Hz AC-3e), 4 kW (at 440V AC 50 Hz AC-3e), 5.5 kW (at 500V AC 50 Hz AC-3e), 5.5 kW (at 660 to 690V AC 50 Hz AC-3e) |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Rated Breaking Capacity | 250 A @ 440V |
Max. Temperature | 850°C |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Environmental Attributes | Mercury Free, Pollution Degree 3 |
Horsepower @ Single Phase - 240V AC | 1 hp |
Horsepower @ Three Phase - 480V AC | 5 hp |
Mechanical Operating Durability | 15,000,000 |
Horsepower @ Three Phase - 240V AC | 2 hp |
Overall Width | 1.77 in |
Horsepower @ Three Phase - 600V AC | 7 1/2 hp |
Mounting Style | DIN Rail, Plate |
Resistance Properties | Fire Resistant, Insulation Resistant |
Overall Height | 3.03 in |
Maximum Operating Temperature | 140 Degrees F |
Embedded Surge Suppressor | No |
Horsepower @ Three Phase - 208V AC | 2 hp |
Phase | Three |
Full Load Current - Resistive | 20 A |
NEMA Enclosure Rating | No Enclosure |
Overall Depth | 3.39 in |
Full Load Current - Inductive | 9 A |
Contactor Style | IEC |
Reversing Capability | Non-Reversing |
Maximum Voltage Rating | 690V AC |
Coil Voltage | 24-60V AC/DC |
Electrical Operating Durability | 2,400,000, 600,000 |
Frequency | 50/60 Hz |
NEMA Enclosure Material | Not Applicable |
Number of Normally Open Main Contacts | 3 |
Minimum Operating Temperature | -40 Degrees F |
Number of Auxillary Contacts | 2 |
Terminal Connection Type | Screw Clamp Terminals |
Horsepower @ Single Phase - 120V AC | 1/3 hp |
Includes Auxiliary Contacts | Yes |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 to 60 V AC/DC, 9 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D09BNE
-3% / ea
with subscription
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24-60V AC/DC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$45.19
You must be logged in to post a review.