IEC Magnetic Contactor, 3 Poles, 48 to 130 V AC/DC, 38 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D38EHE

$134,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 48-130V AC/DC, Number of Poles 3, Full Load Current - Inductive 38 A, Full Load Current - Resistive 50 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$134.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D38EHE
Availability: Ships in 49 days
SKU: GRG6029033 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive38 A
Full Load Amps-Resistive50 A
Number of Poles3
Coil Volts48 to 130 V AC/DC
ReversingNo
HP @ 1 Phase - 120V2 hp
Height3.35 in
HP @ 1 Phase - 240V5 hp
Width1.77 in
HP @ 3 Phase - 208V10 hp
Depth3.62 in
HP @ 3 Phase - 240V10 hp
HP @ 3 Phase - 575V25 hp
HP @ 3 Phase - 480V20 hp
Enclosure NEMA RatingNo Enclosure
Aux. Contact Configuration1NO/1NC
Hz50/60
Frame / Series / Class / CodeTeSys
StandardsCCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1
Auxiliary Contact Form1NO/1NC
NEMA SizeNot Applicable
SeriesTeSys Deca
Electrical ConnectionScrew Clamp Terminals
Non-Overlap Time1.5 ms
Rated Breaking Capacity550 A @ 440V
Operating Speed3600 cycles per hr
FeaturesBuilt-In Bi-Directional Peak Limiting
ApplicationMotor Control, Resistive Load
Rated Insulation Volts690V
Overvoltage CategoryCAT III
Rated Short-Time Withstand Current100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit), 60 A (at 40°C for 10 min Power Circuit), 150 A (at 40°C for 1 min Power Circuit), 310 A (at 40°C for 10 s Power Circuit), 430 A (at 40°C for 1 s Power Circuit)
Max. Operating Watts9 kW (at 220 to 230V AC 50 Hz AC-3), 18.5 kW (at 380 to 400V AC 50 Hz AC-3), 18.5 kW (at 415V AC 50 Hz AC-3), 18.5 kW (at 440V AC 50 Hz AC-3), 18.5 kW (at 500V AC 50 Hz AC-3), 18.5 kW (at 660 to 690V AC 50 Hz AC-3), 9 kW (at 220 to 230V AC 50 Hz AC-3e), 18.5 kW (at 380 to 400V AC 50 Hz AC-3e), 18.5 kW (at 415V AC 50 Hz AC-3e), 18.5 kW (at 440V AC 50 Hz AC-3e), 18.5 kW (at 500V AC 50 Hz AC-3e), 18.5 kW (at 660 to 690V AC 50 Hz AC-3e)
Signalling Circuit Frequency25 to 400 Hz
Net Weight0.442 kg
Electrical Durability1.8 Mcycles (35 A, AC-3, Less than 440 V), 0.9 Mcycles (50 A, AC-1, Less than 440 V), 1.8 Mcycles (35 A, AC-3e, Less than 440 V)
Impedance2 mOhm
Max. Temperature850°C
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 550 A @ 440V (Power Circuit)
Rated Voltage690V AC
Environmental AttributesMercury Free, Pollution Degree 3
Fire RatingUL 94 V1
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Watts Loss0.8W
Operating Time45 to 55 ms (Closing), 20 to 90 ms (Opening)
Tightening Torque1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
Mounts OnPlate, Rail
Impulse Withstand Voltage6 kV
Switching Current5 mA (Signalling Circuit)
Shock Resistance8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Control Circuit Voltage LimitsDrop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C), Operational AC/DC: 0.85 to 1.1 Uc (at -40 to 60°C), 1 to 1.1 Uc (at 60 to 70°C)
Thermal Amperage10 A (at 60°C Signalling Circuit), 50 A (at 60°C Power Circuit)
Working HeightUp to 9842.52 ft
Includes Protective CoverYes
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Hold VA1.3 VA
Inrush VA25 VA
Mechanical Durability15 Mcycles
IP RatingIP20
Switching Voltage17 V (Signalling Circuit)
Fuse Amps10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 63 A (Type 2 Power Circuit)
Full Load Current - Resistive50 A
Mounting StyleDIN Rail, Plate
Horsepower @ Three Phase - 600V AC25 hp
Contactor StyleIEC
Horsepower @ Single Phase - 120V AC2 hp
Embedded Surge SuppressorNo
Horsepower @ Three Phase - 208V AC10 hp
Terminal Connection TypeScrew Clamp Terminals
Mechanical Operating Durability15,000,000
Frequency50/60 Hz
Horsepower @ Three Phase - 240V AC10 hp
Maximum Voltage Rating690V AC
Horsepower @ Single Phase - 240V AC5 hp
Maximum Operating Temperature140 Degrees F
Minimum Operating Temperature-40 Degrees F
Number of Auxillary Contacts2
Coil Voltage48-130V AC/DC
NEMA Enclosure RatingNo Enclosure
Overall Height3.35 in
Includes Auxiliary ContactsYes
Electrical Operating Durability1,800,000, 900,000
PhaseThree
Number of Normally Open Main Contacts3
Resistance PropertiesFire Resistant, Insulation Resistant
Full Load Current - Inductive38 A
Reversing CapabilityNon-Reversing
Overall Depth3.62 in
Horsepower @ Three Phase - 480V AC20 hp
Overall Width1.77 in
NEMA Enclosure MaterialNot Applicable
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#48 to 130 V AC/DC
#38 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D38EHE
#SCHNEIDER ELECTRIC
#GRG6029033
#mfr:LC1D38EHE
#part number:LC1D38EHE
#pn:LC1D38EHE
#part code:LC1D38EHE
#item number:LC1D38EHE
#product code:LC1D38EHE
#manufacturer number:LC1D38EHE
#manufacturers part number:LC1D38EHE
#mfn:LC1D38EHE

Reviews

There are no reviews yet.

Add a review