Full Load Amps-Inductive | 65 A |
Item | IEC Magnetic Contactor |
Full Load Amps-Resistive | 80 A |
Number of Poles | 3 |
Coil Volts | 24 to 60 V AC/DC |
Reversing | No |
HP @ 1 Phase - 120V | 5 hp |
Height | 4.8 in |
HP @ 1 Phase - 240V | 10 hp |
Width | 2.17 in |
HP @ 3 Phase - 208V | 20 hp |
Depth | 4.72 in |
HP @ 3 Phase - 575V | 50 hp |
HP @ 3 Phase - 240V | 20 hp |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 40 hp |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Standards | CCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1 |
Frame / Series / Class / Code | TeSys |
Series | TeSys Deca |
Auxiliary Contact Form | 1NO/1NC |
NEMA Size | Not Applicable |
Includes | Everlink Power Connections |
Inrush VA | 15 VA |
Hold VA | 1 VA |
Impulse Withstand Voltage | 6 kV |
Thermal Amperage | 80 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit) |
Operating Speed | 3600 cycles per hr |
Switching Voltage | 17 V (Signalling Circuit) |
Rated Breaking Capacity | 1000 A @ 440V |
Control Circuit Voltage Limits | Drop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C), Operational AC: 0.85 to 1.1 Uc (at -40 to 60°C), Operational DC: 0.8 to 1.1 Uc (at -40 to 60°C), Operational AC/DC 1 to 1.1 Uc (at 60 to 70°C) |
Fuse Amps | 125 A (Type 1 and 2 Power Circuit), 10 A (Signalling Circuit) |
Watts Loss | 0.7W |
Max. Temperature | 850°C |
Impedance | 1.5 mOhm |
Rated Voltage | 690V AC |
Tightening Torque | 1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Fire Rating | UL 94 V1 |
Signalling Circuit Frequency | 25 to 400 Hz |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Includes Protective Cover | Yes |
Working Height | Up to 9842.52 ft |
Operating Time | 55 to 65 ms (Closing), 20 to 120 ms (Opening) |
Rated Making Capacity | 1000 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Mounts On | Plate, Rail |
Application | Motor Control, Resistive Load |
Net Weight | 1.002 kg |
Environmental Attributes | Mercury Free, Pollution Degree 3 |
Switching Current | 5 mA (Signalling Circuit) |
Max. Operating Watts | 18.5 kW (at 220 to 230V AC 50 Hz AC-3), 30 kW (at 380 to 400V AC 50 Hz AC-3), 37 kW (at 415V AC 50 Hz AC-3), 37 kW (at 440V AC 50 Hz AC-3), 37 kW (at 500V AC 50 Hz AC-3), 37 kW (at 660 to 690V AC 50 Hz AC-3), 18.5 kW (at 220 to 230V AC 50 Hz AC-3e), 30 kW (at 380 to 400V AC 50 Hz AC-3e), 37 kW (at 415V AC 50 Hz AC-3e), 37 kW (at 440V AC 50 Hz AC-3e), 37 kW (at 500V AC 50 Hz AC-3e), 37 kW (at 660 to 690V AC 50 Hz AC-3e) |
Electrical Durability | 1.8 Mcycles (57 A, AC-3, Less than 440 V), 0.5 Mcycles (80 A, AC-1, Less than 440 V), 1.8 Mcycles (57 A, AC-3e, Less than 440 V) |
IP Rating | IP20 |
Mechanical Durability | 6 Mcycles |
Electrical Connection | Control Circuit: Screw Clamp Terminals, Power Circuit: EverLink BTR Screw Connectors |
Features | Built-In Bi-Directional Peak Limiting |
Rated Short-Time Withstand Current | 110 A (at 40°C for 10 min Power Circuit), 260 A (at 40°C for 1 min Power Circuit), 520 A (at 40°C for 10 s Power Circuit), 900 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Overvoltage Category | CAT III |
Rated Insulation Volts | 690V |
Non-Overlap Time | 1.5 ms |
Includes Auxiliary Contacts | Yes |
Phase | Three |
Horsepower @ Three Phase - 480V AC | 40 hp |
Mechanical Operating Durability | 6,000,000 |
Horsepower @ Single Phase - 120V AC | 5 hp |
Mounting Style | DIN Rail, Plate |
Terminal Connection Type | Screw Clamp Terminals |
NEMA Enclosure Material | Not Applicable |
Maximum Operating Temperature | 140 Degrees F |
Resistance Properties | Fire Resistant |
Number of Auxillary Contacts | 2 |
Full Load Current - Inductive | 65 A |
Overall Height | 4.8 in |
NEMA Enclosure Rating | No Enclosure |
Horsepower @ Three Phase - 208V AC | 20 hp |
Contactor Style | IEC |
Overall Width | 2.17 in |
Reversing Capability | Non-Reversing |
Electrical Operating Durability | 1,800,000, 500,000 |
Horsepower @ Three Phase - 600V AC | 50 hp |
Number of Normally Open Main Contacts | 3 |
Frequency | 50/60 Hz |
Full Load Current - Resistive | 80 A |
Maximum Voltage Rating | 690V AC |
Embedded Surge Suppressor | No |
Minimum Operating Temperature | -40 Degrees F |
Coil Voltage | 24-60V AC/DC |
Horsepower @ Single Phase - 240V AC | 10 hp |
Horsepower @ Three Phase - 240V AC | 20 hp |
Overall Depth | 4.72 in |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 to 60 V AC/DC, 65 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D65ABNE
$172,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24-60V AC/DC, Number of Poles 3, Full Load Current - Inductive 65 A, Full Load Current - Resistive 80 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
Out of stock
You must be logged in to post a review.