Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 9 A |
Full Load Amps-Resistive | 20 A |
Number of Poles | 3 |
Coil Volts | 24 to 60 V AC/DC |
Reversing | Yes |
HP @ 1 Phase - 120V | 1/3 hp |
Height | 3.03 in |
HP @ 1 Phase - 240V | 1 hp |
HP @ 3 Phase - 208V | 2 hp |
Width | 3.54 in |
HP @ 3 Phase - 575V | 7 1/2 hp |
Depth | 3.38 in |
HP @ 3 Phase - 240V | 2 hp |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 5 hp |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Standards | CCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1 |
Frame / Series / Class / Code | TeSys |
Series | TeSys Deca |
NEMA Size | Not Applicable |
Auxiliary Contact Form | 1NO/1NC |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit) |
Watts Loss | 0.6W |
Fuse Amps | 10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit) |
Electrical Connection | Screw Clamp Terminals |
Mounts On | Plate, Rail |
Rated Making Capacity | 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Environmental Attributes | Mercury Free, Pollution Degree 3 |
Working Height | Up to 9842.52 ft |
Operating Time | 45 to 55 ms (Closing), 20 to 90 ms (Opening) |
Signalling Circuit Frequency | 25 to 400 Hz |
IP Rating | IP20 |
Hold VA | 0.9 VA |
Non-Overlap Time | 1.5 ms |
Rated Insulation Volts | 690V |
Fire Rating | UL 94 V1 |
Impulse Withstand Voltage | 6 kV |
Overvoltage Category | CAT III |
Impedance | 2.5 mOhm |
Rated Short-Time Withstand Current | 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Inrush VA | 15 VA |
Features | Built-In Bi-Directional Peak Limiting, Preassembled with Reversing Power Busbar |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Control Circuit Voltage Limits | Drop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C), Operational AC: 0.85 to 1.1 Uc (at -40 to 60°C), Operational DC: 0.8 to 1.1 Uc (at -40 to 60°C), Operational AC/DC 1 to 1.1 Uc (at 60 to 70°C) |
Max. Temperature | 850°C |
Rated Voltage | 690V AC |
Max. Operating Watts | 2.2 kW (at 220 to 230V AC 50 Hz), 4 kW (at 380 to 400V AC 50 Hz), 4 kW (at 415V AC 50 Hz), 4 kW (at 440V AC 50 Hz), 5.5 kW (at 500V AC 50 Hz), 5.5 kW (at 660 to 690V AC 50 Hz) |
Application | Motor Control, Resistive Load |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Net Weight | 0.783 kg |
Operating Speed | 3600 cycles per hr |
Rated Breaking Capacity | 250 A @ 440V |
Switching Current | 5 mA (Signalling Circuit) |
Electrical Durability | 2.4 Mcycles (8 A, AC-3, Less than 440 V), 0.6 Mcycles (25 A, AC-1, Less than 440 V) |
Tightening Torque | 1.7 Nm |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Mechanical Durability | 15 Mcycles |
Includes Protective Cover | Yes |
Switching Voltage | 17 V (Signalling Circuit) |
Mechanical Operating Durability | 15,000,000 |
Frequency | 50/60 Hz |
Horsepower @ Three Phase - 240V AC | 2 hp |
Maximum Operating Temperature | 140 Degrees F |
Maximum Voltage Rating | 690V AC |
Horsepower @ Three Phase - 208V AC | 2 hp |
Resistance Properties | Fire Resistant, Insulation Resistant |
Coil Voltage | 24-60V AC/DC |
Horsepower @ Single Phase - 240V AC | 1 hp |
Full Load Current - Resistive | 20 A |
NEMA Enclosure Material | Not Applicable |
NEMA Enclosure Rating | No Enclosure |
Contactor Style | IEC |
Electrical Operating Durability | 2,400,000, 600,000 |
Includes Auxiliary Contacts | Yes |
Number of Normally Open Main Contacts | 3 |
Overall Depth | 3.39 in |
Minimum Operating Temperature | -40 Degrees F |
Full Load Current - Inductive | 9 A |
Overall Height | 3.03 in |
Horsepower @ Three Phase - 480V AC | 5 hp |
Number of Auxillary Contacts | 2 |
Horsepower @ Three Phase - 600V AC | 7 1/2 hp |
Reversing Capability | Reversing |
Mounting Style | DIN Rail, Plate |
Embedded Surge Suppressor | No |
Overall Width | 3.54 in |
Horsepower @ Single Phase - 120V AC | 1/3 hp |
Terminal Connection Type | Screw Clamp Terminals |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 to 60 V AC/DC, 9 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2D09BNE
$136,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24-60V AC/DC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Reversing, Overall Height 3.03 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$136.99
You must be logged in to post a review.