Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 18 A |
Full Load Amps-Resistive | 32 A |
Number of Poles | 3 |
Coil Volts | 100 to 250 V AC/DC |
Reversing | Yes |
HP @ 1 Phase - 120V | 1 hp |
HP @ 1 Phase - 240V | 3 hp |
Height | 3.03 in |
Width | 3.54 in |
HP @ 3 Phase - 208V | 5 hp |
HP @ 3 Phase - 240V | 5 hp |
Depth | 3.38 in |
HP @ 3 Phase - 575V | 15 hp |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 10 hp |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Standards | CCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1 |
Frame / Series / Class / Code | TeSys |
Auxiliary Contact Form | 1NO/1NC |
Series | TeSys Deca |
NEMA Size | Not Applicable |
Control Circuit Voltage Limits | Drop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C), Operational AC/DC: 0.85 to 1.1 Uc (at -40 to 60°C), 1 to 1.1 Uc (at 60 to 70°C) |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit) |
Electrical Durability | 2.2 Mcycles (15 A, AC-3, Less than 440 V), 0.9 Mcycles (32 A, AC-1, Less than 440 V) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Operating Speed | 3600 cycles per hr |
Rated Short-Time Withstand Current | 40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Mechanical Durability | 15 Mcycles |
Application | Motor Control, Resistive Load |
Thermal Amperage | 32 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit) |
Tightening Torque | 1.7 Nm |
Operating Time | 45 to 55 ms (Closing), 20 to 90 ms (Opening) |
Rated Voltage | 690V AC |
Hold VA | 1.6 VA |
Non-Overlap Time | 1.5 ms |
IP Rating | IP20 |
Max. Temperature | 850°C |
Net Weight | 0.803 kg |
Electrical Connection | Screw Clamp Terminals |
Switching Current | 5 mA (Signalling Circuit) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Fire Rating | UL 94 V1 |
Max. Operating Watts | 4 kW (at 220 to 230V AC 50 Hz), 7.5 kW (at 380 to 400V AC 50 Hz), 9 kW (at 415V AC 50 Hz), 9 kW (at 440V AC 50 Hz), 10 kW (at 500V AC 50 Hz), 10 kW (at 660 to 690V AC 50 Hz) |
Fuse Amps | 10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit) |
Rated Breaking Capacity | 300 A @ 440V |
Mounts On | Plate, Rail |
Environmental Attributes | Mercury Free, Pollution Degree 3 |
Includes Protective Cover | Yes |
Rated Insulation Volts | 690V |
Features | Built-In Bi-Directional Peak Limiting, Preassembled with Reversing Power Busbar |
Switching Voltage | 17 V (Signalling Circuit) |
Overvoltage Category | CAT III |
Working Height | Up to 9842.52 ft |
Impulse Withstand Voltage | 6 kV |
Watts Loss | 1.1W |
Signalling Circuit Frequency | 25 to 400 Hz |
Inrush VA | 25 VA |
Impedance | 2.5 mOhm |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Horsepower @ Three Phase - 208V AC | 5 hp |
Horsepower @ Single Phase - 240V AC | 3 hp |
Horsepower @ Three Phase - 600V AC | 15 hp |
Frequency | 50/60 Hz |
Terminal Connection Type | Screw Clamp Terminals |
Includes Auxiliary Contacts | Yes |
Electrical Operating Durability | 2,200,000, 900,000 |
Horsepower @ Single Phase - 120V AC | 1 hp |
Overall Height | 3.03 in |
NEMA Enclosure Material | Not Applicable |
Coil Voltage | 100-250V AC/DC |
Full Load Current - Inductive | 18 A |
Resistance Properties | Fire Resistant, Insulation Resistant |
Number of Normally Open Main Contacts | 3 |
Mounting Style | DIN Rail, Plate |
Horsepower @ Three Phase - 240V AC | 5 hp |
Number of Auxillary Contacts | 2 |
Minimum Operating Temperature | -40 Degrees F |
Maximum Voltage Rating | 690V AC |
Embedded Surge Suppressor | No |
Mechanical Operating Durability | 15,000,000 |
Maximum Operating Temperature | 140 Degrees F |
Contactor Style | IEC |
Horsepower @ Three Phase - 480V AC | 10 hp |
Overall Width | 3.54 in |
Overall Depth | 3.39 in |
Reversing Capability | Reversing |
NEMA Enclosure Rating | No Enclosure |
Country of Origin (subject to change) | United Kingdom |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 100 to 250 V AC/DC, 18 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2D18KUE
$169,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 100-250V AC/DC, Number of Poles 3, Full Load Current - Inductive 18 A, Reversing Capability Reversing, Overall Height 3.03 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 5 hp
9999 in stock
Must order in multiples of 1
Subtotal:
$169.99