IEC Magnetic Contactor, 3 Poles, 24 to 60 V AC/DC, 25 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2D25BNE

$267,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24-60V AC/DC, Number of Poles 3, Full Load Current - Inductive 25 A, Full Load Current - Resistive 40 A, Reversing Capability Reversing, Overall Height 3.35 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$267.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC2D25BNE
Availability: Ships in 51 days
SKU: GRG6049729 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive25 A
Full Load Amps-Resistive40 A
Number of Poles3
Coil Volts24 to 60 V AC/DC
ReversingYes
HP @ 1 Phase - 120V2 hp
HP @ 1 Phase - 240V3 hp
Height3.35 in
Width3.54 in
HP @ 3 Phase - 208V7 1/2 hp
HP @ 3 Phase - 240V7 1/2 hp
HP @ 3 Phase - 575V20 hp
Depth3.62 in
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V15 hp
Aux. Contact Configuration1NO/1NC
Hz50/60
Frame / Series / Class / CodeTeSys
StandardsCCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1
NEMA SizeNot Applicable
SeriesTeSys Deca
Auxiliary Contact Form1NO/1NC
Inrush VA15 VA
Rated Insulation Volts690V
Mechanical Durability15 Mcycles
Rated Voltage690V AC
Working HeightUp to 9842.52 ft
Operating Time45 to 55 ms (Closing), 20 to 90 ms (Opening)
Thermal Amperage10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit)
Max. Operating Watts5.5 kW (at 220 to 230V AC 50 Hz), 11 kW (at 380 to 400V AC 50 Hz), 11 kW (at 415V AC 50 Hz), 11 kW (at 440V AC 50 Hz), 15 kW (at 500V AC 50 Hz), 15 kW (at 660 to 690V AC 50 Hz)
Max. Temperature850°C
Net Weight0.913 kg
Environmental AttributesMercury Free, Pollution Degree 3
Mounts OnPlate, Rail
Impulse Withstand Voltage6 kV
Watts Loss0.6W
Fire RatingUL 94 V1
Fuse Amps10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit)
Operating Speed3600 cycles per hr
Non-Overlap Time1.5 ms
Rated Short-Time Withstand Current50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Overvoltage CategoryCAT III
Switching Voltage17 V (Signalling Circuit)
ApplicationMotor Control, Resistive Load
Switching Current5 mA (Signalling Circuit)
Hold VA0.9 VA
Control Circuit Voltage LimitsDrop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C), Operational AC: 0.85 to 1.1 Uc (at -40 to 60°C), Operational DC: 0.8 to 1.1 Uc (at -40 to 60°C), Operational AC/DC 1 to 1.1 Uc (at 60 to 70°C)
Electrical Durability2 Mcycles (21 A, AC-3, Less than 440 V), 0.9 Mcycles (40 A, AC-1, Less than 440 V)
Includes Protective CoverYes
Tightening Torque1.7 Nm (Control Circuit), 1.7 to 2.5 Nm (Power Circuit)
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Shock Resistance8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit)
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
FeaturesBuilt-In Bi-Directional Peak Limiting, Preassembled with Reversing Power Busbar
Electrical ConnectionScrew Clamp Terminals
Signalling Circuit Frequency25 to 400 Hz
IP RatingIP20
Rated Breaking Capacity450 A @ 440V
Impedance2 mOhm
Frequency50/60 Hz
Horsepower @ Three Phase - 240V AC7 1/2 hp
Maximum Operating Temperature140 Degrees F
Electrical Operating Durability2,000,000, 900,000
NEMA Enclosure RatingNo Enclosure
Mechanical Operating Durability15,000,000
Coil Voltage24-60V AC/DC
Horsepower @ Single Phase - 120V AC2 hp
Overall Width3.54 in
Resistance PropertiesFire Resistant, Insulation Resistant
Contactor StyleIEC
Number of Auxillary Contacts2
Overall Depth3.62 in
Number of Normally Open Main Contacts3
Horsepower @ Three Phase - 480V AC15 hp
Horsepower @ Three Phase - 600V AC20 hp
Mounting StyleDIN Rail, Plate
Maximum Voltage Rating690V AC
Includes Auxiliary ContactsYes
Terminal Connection TypeScrew Clamp Terminals
Horsepower @ Single Phase - 240V AC3 hp
Overall Height3.35 in
NEMA Enclosure MaterialNot Applicable
Embedded Surge SuppressorNo
Full Load Current - Inductive25 A
Full Load Current - Resistive40 A
Minimum Operating Temperature-40 Degrees F
Reversing CapabilityReversing
Horsepower @ Three Phase - 208V AC7 1/2 hp
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#24 to 60 V AC/DC
#25 A
#Reversing: Yes
#SCHNEIDER ELECTRIC
#Mfr LC2D25BNE
#SCHNEIDER ELECTRIC
#GRG6049729
#mfr:LC2D25BNE
#part number:LC2D25BNE
#pn:LC2D25BNE
#part code:LC2D25BNE
#item number:LC2D25BNE
#product code:LC2D25BNE
#manufacturer number:LC2D25BNE
#manufacturers part number:LC2D25BNE
#mfn:LC2D25BNE

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!