IEC Magnetic Contactor, 3 Poles, 120 V AC, 9 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2D09G7V

-$9.36 / ea
with subscription
Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Reversing, Overall Height 3.03 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 2 hp

9999 in stock

Must order in multiples of 1
Subtotal:
$311.99
Final shipping and tax calculated in checkout
Subtotal: $302.63 with subscription
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC2D09G7V
Availability: Ships in 1 days
SKU: GRG1099122 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive9 A
Full Load Amps-Resistive20 A
ActionReversing
Number of Poles3
Coil Volts120 V AC
ReversingYes
HP @ 1 Phase - 120V1/2 hp
HP @ 1 Phase - 230V1
HP @ 1 Phase - 240V1 hp
Height3.54 in
Width3.54 in
HP @ 3 Phase - 208V2 hp
HP @ 3 Phase - 575V7 1/2 hp
Depth3.54 in
HP @ 3 Phase - 240V2 hp
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V5 hp
Aux. Contact Configuration1NO/1NC
Hz50/60
Frame / Series / Class / CodeTeSys
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Auxiliary Contact Form1NO/1NC
IncludesElectrical Interlock, Mechanical Interlock
SeriesTeSys Deca
NEMA SizeNot Applicable
Electrical Durability0.6 Mcycles (25 A, AC-1, Less than 440 V), 2 Mcycles (9 A, AC-3, Less than 440 V)
Max. Operating Watts2.2 kW (at 220 to 230V AC 50 Hz), 4 kW (at 380 to 400V AC 50 Hz), 4 kW (at 415 to 440V AC 50 Hz), 5.5 kW (at 500V AC 50 Hz), 5.5 kW (at 660 to 690V AC 50 Hz)
Rated Short-Time Withstand Current30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Operating Time12 to 22 ms (Closing), 4 to 19 ms (Opening)
Mounts OnPlate, Rail
Net Weight0.687 kg
Non-Overlap Time1.5 ms
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
IP RatingIP20
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Fuse Amps25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit), 10 A (Signalling Circuit)
Watts Loss2 to 3W
Rated Making Capacity250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Operating Speed3600 cycles per hr
Impedance2.5 mOhm
Electrical ConnectionScrew Clamp Terminals
Signalling Circuit Frequency25 to 400 Hz
Switching Voltage17 V (Signalling Circuit)
Shock Resistance15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Working HeightUp to 9842.52 ft
Overvoltage CategoryCAT III
Rated Insulation Volts600/690V
Max. Temperature850°C
FeaturesWithout Built-In Suppressor Module, Preassembled with Reversing Power Busbar
Tightening Torque1.7 Nm (Control Circuit), 1.7 to 2.5 Nm (Power Circuit)
Fire RatingUL 94 V1
Includes Protective CoverYes
Mechanical Durability15 Mcycles
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Inrush VA70 VA
Rated Breaking Capacity250 A @ 440V
Thermal Amperage10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit)
Switching Current5 mA (Signalling Circuit)
Impulse Withstand Voltage6 kV
Hold VA7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Rated Voltage690V AC, 300V DC
ApplicationMotor Control, Resistive Load
Overall Width3.54 in
Horsepower @ Three Phase - 208V AC2 hp
Embedded Surge SuppressorNo
Coil Voltage120V AC
Full Load Current - Inductive9 A
Minimum Operating Temperature-40 Degrees F
Overall Depth3.39 in
Contactor StyleIEC
NEMA Enclosure MaterialNot Applicable
Maximum Voltage Rating690V AC
Horsepower @ Three Phase - 480V AC5 hp
Reversing CapabilityReversing
PhaseThree
Horsepower @ Single Phase - 120V AC1/2 hp
Number of Auxillary Contacts2
Mechanical Operating Durability15,000,000
NEMA Enclosure RatingNo Enclosure
Maximum Operating Temperature140 Degrees F
Includes Auxiliary ContactsYes
Mounting StyleDIN Rail, Plate
Number of Normally Open Main Contacts3
Terminal Connection TypeScrew Clamp Terminals
Resistance PropertiesFire Resistant
Horsepower @ Three Phase - 600V AC7 1/2 hp
Overall Height3.03 in
Horsepower @ Three Phase - 240V AC2 hp
Frequency50/60 Hz
Horsepower @ Single Phase - 240V AC1 hp
Electrical Operating Durability2,000,000, 600,000
Full Load Current - Resistive20 A
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#120 V AC
#9 A
#Reversing: Yes
#SCHNEIDER ELECTRIC
#Mfr LC2D09G7V
#SCHNEIDER ELECTRIC
#GRG1099122
#mfr:LC2D09G7V
#part number:LC2D09G7V
#pn:LC2D09G7V
#part code:LC2D09G7V
#item number:LC2D09G7V
#product code:LC2D09G7V
#manufacturer number:LC2D09G7V
#manufacturers part number:LC2D09G7V
#mfn:LC2D09G7V

Reviews

There are no reviews yet.

Add a review