Full Load Amps-Inductive | 9 A |
Item | IEC Magnetic Contactor |
Full Load Amps-Resistive | 20 A |
Action | Reversing |
Number of Poles | 3 |
Coil Volts | 240 V AC |
Reversing | Yes |
HP @ 1 Phase - 230V | 1 |
HP @ 1 Phase - 120V | 1/2 hp |
Height | 3.54 in |
HP @ 1 Phase - 240V | 1 hp |
Width | 3.54 in |
HP @ 3 Phase - 208V | 2 hp |
HP @ 3 Phase - 575V | 7 1/2 hp |
HP @ 3 Phase - 240V | 2 hp |
Depth | 3.54 in |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 5 hp |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Includes | Electrical Interlock, Mechanical Interlock |
Auxiliary Contact Form | 1NO/1NC |
Frame / Series / Class / Code | TeSys |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Series | TeSys Deca |
NEMA Size | Not Applicable |
Mechanical Durability | 15 Mcycles |
Fuse Amps | 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit), 10 A (Signalling Circuit) |
Rated Insulation Volts | 600/690V |
Fire Rating | UL 94 V1 |
Switching Voltage | 17 V (Signalling Circuit) |
Electrical Durability | 0.6 Mcycles (25 A, AC-1, Less than 440 V), 2 Mcycles (9 A, AC-3, Less than 440 V) |
Max. Temperature | 850°C |
Signalling Circuit Frequency | 25 to 400 Hz |
Electrical Connection | Screw Clamp Terminals |
Mounts On | Plate, Rail |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Impedance | 2.5 mOhm |
Switching Current | 5 mA (Signalling Circuit) |
Rated Short-Time Withstand Current | 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Overvoltage Category | CAT III |
Application | Motor Control, Resistive Load |
IP Rating | IP20 |
Net Weight | 0.687 kg |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit) |
Operating Speed | 3600 cycles per hr |
Rated Voltage | 690V AC, 300V DC |
Max. Operating Watts | 2.2 kW (at 220 to 230V AC 50 Hz), 4 kW (at 380 to 400V AC 50 Hz), 4 kW (at 415 to 440V AC 50 Hz), 5.5 kW (at 500V AC 50 Hz), 5.5 kW (at 660 to 690V AC 50 Hz) |
Watts Loss | 2 to 3W |
Working Height | Up to 9842.52 ft |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Non-Overlap Time | 1.5 ms |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Tightening Torque | 1.7 Nm (Control Circuit), 1.7 to 2.5 Nm (Power Circuit) |
Inrush VA | 70 VA |
Rated Breaking Capacity | 250 A @ 440V |
Rated Making Capacity | 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Impulse Withstand Voltage | 6 kV |
Features | Without Built-In Suppressor Module, Preassembled with Reversing Power Busbar |
Includes Protective Cover | Yes |
Horsepower @ Three Phase - 240V AC | 2 hp |
Maximum Operating Temperature | 140 Degrees F |
Minimum Operating Temperature | -40 Degrees F |
NEMA Enclosure Rating | No Enclosure |
Overall Depth | 3.39 in |
Horsepower @ Single Phase - 240V AC | 1 hp |
Reversing Capability | Reversing |
Electrical Operating Durability | 2,000,000, 600,000 |
Horsepower @ Three Phase - 208V AC | 2 hp |
Embedded Surge Suppressor | No |
Frequency | 50/60 Hz |
Mounting Style | DIN Rail, Plate |
Horsepower @ Three Phase - 480V AC | 5 hp |
Overall Height | 3.03 in |
Contactor Style | IEC |
Maximum Voltage Rating | 690V AC |
Horsepower @ Single Phase - 120V AC | 1/2 hp |
Overall Width | 3.54 in |
Mechanical Operating Durability | 15,000,000 |
Number of Auxillary Contacts | 2 |
Horsepower @ Three Phase - 600V AC | 7 1/2 hp |
Includes Auxiliary Contacts | Yes |
Full Load Current - Resistive | 20 A |
Resistance Properties | Fire Resistant, Insulation Resistant |
Terminal Connection Type | Screw Clamp Terminals |
Number of Normally Open Main Contacts | 3 |
NEMA Enclosure Material | Not Applicable |
Full Load Current - Inductive | 9 A |
Coil Voltage | 240V AC |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 240 V AC, 9 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2D09U7V
$305,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 240V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Reversing, Overall Height 3.03 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 2 hp