Discount -5%

IEC Magnetic Contactor, 3 Poles, 24 V DC, 12 A, Reversing: Yes, SCHNEIDER, Mfr# LC2D12BD

$386.05

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 12 A, Full Load Current - Resistive 25 A, Reversing Capability Reversing, Overall Height 3.03 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 3 hp

Out of stock

Brand Name: SCHNEIDER
Mfr #: LC2D12BD
Availability: Ships in 1 days
SKU: GRG1768076 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive12 A
Full Load Amps-Resistive25 A
ActionReversing
Number of Poles3
Coil Volts24 V DC
ReversingYes
HP @ 1 Phase - 230V2
HP @ 1 Phase - 120V1 hp
Height3.54 in
HP @ 1 Phase - 240V2 hp
Width3.54 in
HP @ 3 Phase - 208V3 hp
HP @ 3 Phase - 575V10 hp
HP @ 3 Phase - 240V3 hp
Depth3.54 in
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V7 1/2 hp
Aux. Contact Configuration1NO/1NC
Hz50/60
Auxiliary Contact Form1NO/1NC
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
IncludesElectrical Interlock
SeriesTeSys Deca
NEMA SizeNot Applicable
Net Weight1.027 kg
Mounts OnPlate, Rail
Thermal Amperage10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit)
Switching Voltage17 V (Signalling Circuit)
Impulse Withstand Voltage6 kV
Electrical Durability2 Mcycles (12 A, AC-3, Less than 440 V), 0.8 Mcycles (25 A, AC-1, Less than 440 V)
Rated Short-Time Withstand Current30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Rated Breaking Capacity250 A @ 440V
Impedance2.5 mOhm
Rated Voltage690V AC, 300V DC
IP RatingIP20
Working HeightUp to 9842.52 ft
Operating Time53.55 to 72.45 ms (Closing), 16 to 24 ms (Opening)
Mechanical Durability30 Mcycles
Control Circuit Voltage LimitsDrop-Out DC: 0.1 to 0.25 Uc (at -40 to 70°C), Operational DC: 0.7 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C)
Signalling Circuit Frequency25 to 400 Hz
FeaturesBuilt-In Bi-Directional Peak Limiting Diode Suppressor, Preassembled with Reversing Power Busbar
Electrical ConnectionScrew Clamp Terminals
Operating Speed3600 cycles per hr
Rated Making Capacity250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Fuse Amps10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit)
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Non-Overlap Time1.5 ms
Environmental AttributesMercury Free, PVC Free, Pollution Degree 3
Rated Insulation Volts600/690V
Includes Protective CoverYes
Tightening Torque1.7 Nm (Control Circuit), 1.7 to 2.5 Nm (Power Circuit)
Shock Resistance15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
ApplicationMotor Control, Resistive Load
Max. Operating Watts3 kW (at 220 to 230V AC 50 Hz), 5.5 kW (at 380 to 400V AC 50 Hz), 5.5 kW (at 415 to 440V AC 50 Hz), 7.5 kW (at 500V AC 50 Hz), 7.5 kW (at 660 to 690V AC 50 Hz)
Fire RatingUL 94 V1
Overvoltage CategoryCAT III
Max. Temperature850°C
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Switching Current5 mA (Signalling Circuit)
NEMA Enclosure MaterialNot Applicable
Maximum Operating Temperature140 Degrees F
Horsepower @ Three Phase - 600V AC10 hp
Number of Normally Open Main Contacts3
Horsepower @ Three Phase - 480V AC7 1/2 hp
NEMA Enclosure RatingNo Enclosure
Overall Depth3.74 in
Coil Voltage24V DC
Includes Auxiliary ContactsYes
Maximum Voltage Rating690V AC
Overall Height3.03 in
Overall Width3.54 in
Reversing CapabilityReversing
Mounting StyleDIN Rail, Plate
Horsepower @ Three Phase - 240V AC3 hp
Number of Auxillary Contacts2
Frequency50/60 Hz
Resistance PropertiesFire Resistant, Insulation Resistant
Horsepower @ Three Phase - 208V AC3 hp
Full Load Current - Inductive12 A
Contactor StyleIEC
Embedded Surge SuppressorYes
Horsepower @ Single Phase - 120V AC1 hp
Minimum Operating Temperature-40 Degrees F
Mechanical Operating Durability30,000,000
Horsepower @ Single Phase - 240V AC2 hp
Terminal Connection TypeScrew Clamp Terminals
Full Load Current - Resistive25 A
Electrical Operating Durability2,000,000, 800,000
Front CoverWith
Contactor ApplicationMotor control, Resistive load
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Control Circuit TypeDC standard
Fire Resistance1562°F (850°C) IEC 60695-2-1
Minimum Switching Current5 mA for signalling circuit
Motor Power HP1 hp at 115 V AC 60 Hz for 1 phase motors, 2 hp at 230/240 V AC 60 Hz for 1 phase motors, 3 hp at 200/208 V AC 60 Hz for 3 phase motors, 3 hp at 230/240 V AC 60 Hz for 3 phase motors, 7.5 hp at 460/480 V AC 60 Hz for 3 phase motors, 10 hp at 575/600 V AC 60 Hz for 3 phase motors
Power Pole Contact Composition3 NO
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 25 A (at 140°F (60°C)) for power circuit
Hold-In Power Consumption in W5.4 W 68°F (20°C)
Interlocking TypeMechanical
Climatic WithstandIACS E10, IEC 60947-1 Annex Q category D
Auxiliary Contact Composition1 NO + 1 NC
Coil TechnologyBuilt-in bidirectional peak limiting diode suppressor
IP Degree Of ProtectionIP20 front face IEC 60529
Utilisation CategoryAC-1, AC-3, AC-3e
Mechanical RobustnessVibrations contactor open2 Gn, 5 to 300 Hz, Vibrations contactor closed4 Gn, 5 to 300 Hz, Shocks contactor open10 Gn for 11 ms, Shocks contactor closed15 Gn for 11 ms
Power Dissipation Per Pole1.56 W AC-1, 0.36 W AC-3, 0.36 W AC-3e
Time Constant28 ms
Poles Description3P
Inrush Power in W5.4 W 68°F (20°C))
Rated Short Time Withstand Current30 A 104°F (40°C) - 10 min for power circuit, 61 A 104°F (40°C) - 1 min for power circuit, 105 A 104°F (40°C) - 10 s for power circuit, 210 A 104°F (40°C) - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Connections - TerminalsPower circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)flexible without cable end, Power circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?)flexible without cable end, Power circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)flexible with cable end, Power circuit screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?)flexible with cable end, Power circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)solid, Power circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?)solid, Control circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)flexible without cable end, Control circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?)flexible without cable end, Control circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)flexible with cable end, Control circuit screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?)flexible with cable end, Control circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)solid, Control circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?)solid
Rated Operational Current25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Motor Power KW3 kW at 220 to 230 V AC 50 Hz, 5.5 kW at 380 to 400 V AC 50 Hz, 5.5 kW at 415 V AC 50 Hz, 5.5 kW at 440 V AC 50 Hz, 7.5 kW at 500 V AC 50 Hz, 7.5 kW at 660 to 690 V AC 50 Hz
Minimum Switching Voltage17 V for signalling circuit
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Protective TreatmentTH IEC 60068-2-30
IRMS Rated Making Capacity250 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Average Impedance2.5 mOhm - Ith 25 A 50 Hz for power circuit
Product NameTeSys D, TeSys Deca
Pollution Degree3
Ambient Air Temperature For Storage-76 to 176°F (-60 to 80°C)
Product CertificationsDNV, CSA, CCC, UL, GL, LROS (Lloyds register of shipping), BV, RINA, GOST, UKCA
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 40 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 25 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Rated Insulation VoltagePower circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Device PresentationPreassembled with reversing power busbar
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Ambient Air Temperature For Operation-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Rated Impulse Withstand Voltage6 kV IEC 60947
Mounting SupportPlate, Rail
Flame RetardanceV1 conforming to UL 94
Product Or Component TypeReversing contactor
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#24 V DC
#12 A
#Reversing: Yes
#SCHNEIDER
#Mfr LC2D12BD
#SCHNEIDER
#GRG1768076
#mfr:LC2D12BD
#part number:LC2D12BD
#pn:LC2D12BD
#part code:LC2D12BD
#item number:LC2D12BD
#product code:LC2D12BD
#manufacturer number:LC2D12BD
#manufacturers part number:LC2D12BD
#mfn:LC2D12BD

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!