Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 6 A, Full Load Current - Resistive 15 A, Reversing Capability Non-Reversing, Overall Height 2.28 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$65.19
Final shipping and tax calculated in checkout
Subtotal: $63.23 with subscription
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1K0610B7
Availability: Ships in 1 days
SKU: GRG3480425 Category:
Full Load Amps-Inductive6 A
ItemMiniature IEC Magnetic Contactor
ActionNon-Reversing
Full Load Amps-Resistive15 A
Number of Poles3
Coil Volts24 V AC
ReversingNo
HP @ 1 Phase - 120V1/2 hp
HP @ 1 Phase - 230V1-1/2
Height1.73 in
HP @ 1 Phase - 240V1 1/2 hp
Width1.73 in
HP @ 3 Phase - 208V1 1/2 hp
Depth1.97 in
HP @ 3 Phase - 575V3 hp
HP @ 3 Phase - 240V1 1/2 hp
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V3 hp
Aux. Contact Configuration1NO
Hz50/60
StandardsBS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
Frame / Series / Class / CodeTeSys
Auxiliary Contact Form1NO
SeriesTeSys K
NEMA SizeNot Applicable
Electrical ConnectionScrew Clamp Terminals
Working Height6561.68 ft
Rated Short-Time Withstand Current90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 20 A (at 50°C for 15 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit)
Switching Voltage17 V (Signalling Circuit)
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Tightening Torque1.3 Nm
Shock Resistance10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Signalling Circuit FrequencyLess Than 400 Hz
Impulse Withstand Voltage8 kV
Net Weight0.18 kg
Operating Speed3600 cycles per hr
Max. Operating Watts1.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 2.2 kW (at 380 to 415V AC 50/60 Hz AC-3), 3 kW (at 440V AC 50/60 Hz AC-3), 3 kW (at 480V AC 50/60 Hz AC-3), 3 kW (at 500 to 600V AC 50/60 Hz AC-3), 3 kW (at 660 to 690V AC 50/60 Hz AC-3), 1.5 kW (at 400V AC 50/60 Hz AC-4), 1.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 2.2 kW(at 380 to 415V AC 50/60 Hz AC-3e), 3 kW (at 440V AC 50/60 Hz AC-3e), 3 kW (at 480V AC 50/60 Hz AC-3e), 3 kW (at 500 to 600V AC 50/60 Hz AC-3e), 3 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Mechanical Durability10 Mcycles
Control Circuit Voltage LimitsOperational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Rated Insulation Volts600/690V
Impedance3 mOhm
Rated Breaking Capacity110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V
IP RatingIP22
Electrical Durability1.3 Mcycles (6 A, AC-3, Less than 440 V), 1.3 Mcycles (6 A, AC-3e, Less than 440 V)
Environmental AttributesMercury Free, Toxic Heavy Metal Free
Rated Voltage690V AC
Mounts OnPlate, Rail
Fire RatingUL 94 V1, NF F 16-101, NF F 16-102
Inrush VA30 VA
Fuse Amps25 A (Power Circuit), 10 A (Signalling Circuit)
Thermal Amperage20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
Hold VA4.5 VA
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Switching Current5 mA (Signalling Circuit)
Watts Loss1.3W
ApplicationMotor Control
Rated Making Capacity110 A
Overvoltage CategoryCAT III
Operating Time10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing)
Electrical Operating Durability1,300,000
Horsepower @ Three Phase - 480V AC3 hp
Horsepower @ Single Phase - 120V AC1/2 hp
Number of Normally Open Main Contacts3
NEMA Enclosure MaterialNot Applicable
Overall Width1.77 in
Full Load Current - Resistive15 A
Horsepower @ Single Phase - 240V AC1 1/2 hp
Reversing CapabilityNon-Reversing
Mounting StyleDIN Rail, Plate
Mechanical Operating Durability10,000,000
Contactor StyleIEC
Horsepower @ Three Phase - 240V AC1 1/2 hp
Horsepower @ Three Phase - 208V AC1 1/2 hp
Terminal Connection TypeScrew Clamp Terminals
Full Load Current - Inductive6 A
Horsepower @ Three Phase - 600V AC3 hp
NEMA Enclosure RatingNo Enclosure
Frequency50/60 Hz
Maximum Voltage Rating690V AC
Resistance PropertiesInsulation Resistant
Overall Height2.28 in
Number of Auxillary Contacts1
Coil Voltage24V AC
Includes Auxiliary ContactsYes
Embedded Surge SuppressorNo
Overall Depth2.24 in
Country of Origin (subject to change)Multiple
Package Quantity1
TAGS:
#IEC Mini Magnetic Contactor
#3 Poles
#24 V AC
#6 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1K0610B7
#SCHNEIDER ELECTRIC
#GRG3480425
#mfr:LC1K0610B7
#part number:LC1K0610B7
#pn:LC1K0610B7
#part code:LC1K0610B7
#item number:LC1K0610B7
#product code:LC1K0610B7
#manufacturer number:LC1K0610B7
#manufacturers part number:LC1K0610B7
#mfn:LC1K0610B7

Reviews

There are no reviews yet.

Add a review