IEC Mini Magnetic Contactor, 3 Poles, 240 V AC, 12 A, Reversing: Yes, SCHNEIDER, Mfr# LC2K1201U7

$193,99

Free shipping will be applied on orders over $50

Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 240V AC, Number of Poles 3, Full Load Current - Inductive 12 A, Full Load Current - Resistive 20 A, Reversing Capability Reversing, Overall Height 2.28 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$193.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER
Mfr #: LC2K1201U7
Availability: Ships in 15 days
SKU: GRG1336657 Category:
Full Load Amps-Inductive12 A
ItemMiniature IEC Magnetic Contactor
ActionReversing
Full Load Amps-Resistive20 A
Number of Poles3
Coil Volts240 V AC
ReversingYes
HP @ 1 Phase - 230V1-1/2
HP @ 1 Phase - 120V1/2 hp
Height3.54 in
HP @ 1 Phase - 240V1 1/2 hp
Width3.54 in
HP @ 3 Phase - 575V10 hp
Depth2.24 in
HP @ 3 Phase - 240V3 hp
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V7 1/2 hp
Aux. Contact Configuration1NC
Hz50/60
StandardsBS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
Auxiliary Contact Form1NC
SeriesTeSys K
NEMA SizeNot Applicable
Switching Current5 mA (Signalling Circuit)
Inrush VA30 VA
Working Height6561.68 ft
Tightening Torque0.8 to 1.3 Nm
Rated Voltage690V AC
Impedance3 mOhm
Impulse Withstand Voltage8 kV
Operating Time10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening)
Environmental AttributesMercury Free, Toxic Heavy Metal Free
Fire RatingUL 94 V1, NF F 16-101, NF F 16-102
Fuse Amps25 A (Power Circuit), 10 A (Signalling Circuit)
Mounts OnPlate, Rail
Net Weight0.39 kg
Rated Breaking Capacity110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Thermal Amperage20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
Mechanical Durability5 Mcycles
Control Circuit Voltage LimitsOperational: 0.85 to 1.1 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
FeaturesPreassembled with Reversing Power Busbar
Max. Operating Watts4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz), 3 kW (at 220 to 230V AC 50/60 Hz), 5.5 kW (at 380 to 415VAC 50/60 Hz), 5.5 kW (at 440V AC 50/60 Hz)
Signalling Circuit FrequencyLess Than 400 Hz
Watts Loss1.3W
Electrical Durability0.3 Mcycles (20 A, AC-1, Less than 440 V), 1.3 Mcycles (12 A, AC-3, Less than 440 V), 1.3 Mcycles (12 A, AC-3e, Less than 440 V)
ApplicationMotor Control, Resistive Load
Operating Speed3600 cycles per hr
IP RatingIP20
Overvoltage CategoryCAT III
Rated Short-Time Withstand Current115 A (at 50°C for 1 s Power Circuit), 105 A (at 50°C for 5 s Power Circuit), 100 A (at 50°C for 10 s Power Circuit), 75 A (at 50°C for 30 s Power Circuit), 55 A (at 50°C for 1 min Power Circuit), 50 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50°C for 15 min Power Circuit)
Rated Insulation Volts600/690V
Rated Making Capacity144 A @ 690V (AC Power Circuit), 110 A (AC Signalling Circuit)
Hold VA4.5 VA
Electrical ConnectionScrew Clamp Terminals
Shock Resistance10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Switching Voltage17 V (Signalling Circuit)
Contactor StyleIEC
NEMA Enclosure MaterialNot Applicable
Coil Voltage240V AC
Number of Normally Open Main Contacts3
Horsepower @ Single Phase - 240V AC1 1/2 hp
Overall Width3.54 in
Maximum Voltage Rating690V AC
Horsepower @ Single Phase - 120V AC1/2 hp
Horsepower @ Three Phase - 480V AC7 1/2 hp
Resistance PropertiesInsulation Resistant
Horsepower @ Three Phase - 240V AC3 hp
Includes Auxiliary ContactsYes
Overall Height2.28 in
Reversing CapabilityReversing
Maximum Operating Temperature122 Degrees F
Electrical Operating Durability1,300,000, 300,000
Number of Auxillary Contacts1
Full Load Current - Resistive20 A
Mechanical Operating Durability5,000,000
Embedded Surge SuppressorNo
NEMA Enclosure RatingNo Enclosure
Full Load Current - Inductive12 A
Mounting StyleDIN Rail, Plate
Overall Depth2.24 in
Horsepower @ Three Phase - 600V AC10 hp
Terminal Connection TypeScrew Clamp Terminals
Minimum Operating Temperature-13 Degrees F
Frequency50/60 Hz
Rated Short Time Withstand Current115 A 122°F (50°C) - 1 s for power circuit, 105 A 122°F (50°C) - 5 s for power circuit, 100 A 122°F (50°C) - 10 s for power circuit, 75 A 122°F (50°C) - 30 s for power circuit, 55 A 122°F (50°C) - 1 min for power circuit, 50 A 122°F (50°C) - 3 min for power circuit, 25 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit
Power Pole Contact Composition3 NO
Mounting SupportRail, Plate
Flame RetardanceV1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102
Heat Dissipation1.3 W
Utilisation CategoryAC-3, AC-3e, AC-4, AC-1
IP Degree Of ProtectionIP20 VDE 0106
Hold-In Power Consumption in VA4.5 VA (at 68°F (20°C))
Inrush Power in VA30 VA (at 68°F (20°C))
Rated Insulation VoltagePower circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14
Rated Operational Current12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit, 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Auxiliary Contact Composition1 NC
Non Overlap Distance0.02 in (0.5 mm)
Ambient Air Temperature For Operation-13 to 122°F (-25 to 50°C)
Poles Description3P
Ambient Air Temperature For Storage-58 to 176°F (-50 to 80°C)
IRMS Rated Making Capacity144 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947
Interlocking TypeMechanical
Product CertificationsCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
Conventional Free Air Thermal Current20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit
Product Or Component TypeReversing contactor
Contactor ApplicationMotor control, Resistive load
Rated Operational VoltagePower circuit 690 V AC 50/60 Hz, Signalling circuit Less than or Equal to 690 V AC 50/60 Hz
Mechanical RobustnessShocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Protective TreatmentTC IEC 60068, TC DIN 50016
Device ApplicationControl
Associated Fuse Rating25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
Average Impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Control Circuit TypeAC 50/60 Hz
Auxiliary Contacts TypeInstantaneous 1 NC
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Maximum Operating Rate3600 cyc/h
Minimum Switching Current5 mA for signalling circuit
Minimum Switching Voltage17 V for signalling circuit
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Motor Power KW3 kW 220 to 230 V AC 50/60 Hz, 5.5 kW 380 to 415 V AC 50/60 Hz, 5.5 kW 440 V AC 50/60 Hz, 4 kW 690 V AC 50/60 Hz
Connections - Terminalsscrew clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end
Operating Altitude6561.68 ft (2000 m) without derating
Control Circuit Voltage230 to 240 V AC 50/60 Hz
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Mini Magnetic Contactor
#3 Poles
#240 V AC
#12 A
#Reversing: Yes
#SCHNEIDER
#Mfr LC2K1201U7
#SCHNEIDER
#GRG1336657
#mfr:LC2K1201U7
#part number:LC2K1201U7
#pn:LC2K1201U7
#part code:LC2K1201U7
#item number:LC2K1201U7
#product code:LC2K1201U7
#manufacturer number:LC2K1201U7
#manufacturers part number:LC2K1201U7
#mfn:LC2K1201U7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!