Full Load Amps-Inductive | 9 A |
Item | Miniature IEC Magnetic Contactor |
Full Load Amps-Resistive | 20 A |
Action | Reversing |
Number of Poles | 3 |
Coil Volts | 120 V AC |
Reversing | Yes |
HP @ 1 Phase - 120V | 1/2 hp |
HP @ 1 Phase - 230V | 1-1/2 |
HP @ 1 Phase - 240V | 1 1/2 hp |
Height | 3.54 in |
HP @ 3 Phase - 208V | 2 hp |
Width | 3.54 in |
Depth | 1.97 in |
HP @ 3 Phase - 575V | 5 hp |
HP @ 3 Phase - 240V | 3 hp |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 5 hp |
Aux. Contact Configuration | 1NC |
Hz | 50/60 |
Standards | BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660 |
Auxiliary Contact Form | 1NC |
Frame / Series / Class / Code | TeSys |
NEMA Size | Not Applicable |
Series | TeSys K |
Mechanical Durability | 5 Mcycles |
Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
Impulse Withstand Voltage | 8 kV |
Electrical Connection | Screw Clamp Terminals |
Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
Signalling Circuit Frequency | Less Than 400 Hz |
Application | Motor Control, Resistive Load |
Max. Operating Watts | 2.2 kW (at 220 to 230V AC 50/60 Hz), 4 kW (at 380 to 415VAC 50/60 Hz), 4 kW (at 440V AC 50/60 Hz), 4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz) |
Features | Preassembled with Reversing Power Busbar |
Inrush VA | 30 VA |
Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
Overvoltage Category | CAT III |
Switching Voltage | 17 V (Signalling Circuit) |
Rated Making Capacity | 110 A |
Rated Short-Time Withstand Current | 90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 20 A (at 50°C for 15 min Power Circuit) |
IP Rating | IP20 |
Watts Loss | 1.3W |
Rated Insulation Volts | 600/690V |
Thermal Amperage | 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit) |
Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
Electrical Durability | 0.18 Mcycles (20 A, AC-1, Less than 440 V), 1.3 Mcycles (9 A, AC-3, Less than 440 V), 1.3 Mcycles (9 A, AC-3e, Less than 440 V) |
Switching Current | 5 mA (Signalling Circuit) |
Rated Voltage | 690V AC |
Rated Breaking Capacity | 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V |
Working Height | 6561.68 ft |
Tightening Torque | 0.8 to 1.3 Nm |
Operating Time | 10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening) |
Net Weight | 0.39 kg |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Impedance | 3 mOhm |
Hold VA | 4.5 VA |
Operating Speed | 3600 cycles per hr |
Mounts On | Plate, Rail |
Horsepower @ Three Phase - 208V AC | 2 hp |
NEMA Enclosure Rating | No Enclosure |
Reversing Capability | Reversing |
Mechanical Operating Durability | 5,000,000 |
Horsepower @ Three Phase - 480V AC | 5 hp |
Frequency | 50/60 Hz |
Number of Auxillary Contacts | 1 |
Terminal Connection Type | Screw Clamp Terminals |
Full Load Current - Inductive | 9 A |
Embedded Surge Suppressor | No |
Maximum Operating Temperature | 122 Degrees F |
Horsepower @ Single Phase - 240V AC | 1 1/2 hp |
Number of Normally Open Main Contacts | 3 |
Minimum Operating Temperature | -13 Degrees F |
Overall Depth | 2.24 in |
Overall Height | 2.28 in |
Includes Auxiliary Contacts | Yes |
Overall Width | 3.54 in |
Maximum Voltage Rating | 690V AC |
Mounting Style | DIN Rail, Plate |
NEMA Enclosure Material | Not Applicable |
Electrical Operating Durability | 1,300,000, 180,000 |
Horsepower @ Three Phase - 600V AC | 5 hp |
Horsepower @ Three Phase - 240V AC | 3 hp |
Horsepower @ Single Phase - 120V AC | 1/2 hp |
Resistance Properties | Insulation Resistant |
Full Load Current - Resistive | 20 A |
Contactor Style | IEC |
Coil Voltage | 110V AC |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Mini Magnetic Contactor, 3 Poles, 120 V AC, 9 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2K0901F7
-3% / ea
with subscription
Free shipping will be applied on orders over $50
Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 110V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Reversing, Overall Height 2.28 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$184.99
You must be logged in to post a review.