Full Load Amps-Inductive | 9 A |
Item | Miniature IEC Magnetic Contactor |
Action | Non-Reversing |
Full Load Amps-Resistive | 20 A |
Number of Poles | 3 |
Coil Volts | 208 V AC |
Reversing | No |
HP @ 1 Phase - 120V | 1/2 hp |
HP @ 1 Phase - 230V | 1-1/2 |
HP @ 1 Phase - 240V | 1 1/2 hp |
Height | 1.73 in |
HP @ 3 Phase - 208V | 2 hp |
Width | 1.73 in |
HP @ 3 Phase - 240V | 3 hp |
HP @ 3 Phase - 575V | 5 hp |
Depth | 1.97 in |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 5 hp |
Aux. Contact Configuration | 1NO |
Hz | 50/60 |
Standards | CSA, UKCA, UL Listed |
Auxiliary Contact Form | 1NO |
NEMA Size | Not Applicable |
Series | TeSys K |
Impedance | 3 mOhm |
Signalling Circuit Frequency | Less Than 400 Hz |
Switching Voltage | 17 V (Signalling Circuit) |
Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
Working Height | 6561.68 ft |
Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Operating Speed | 3600 cycles per hr |
Control Circuit Voltage Limits | Operational: 0.85 to 1.1 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
Overvoltage Category | CAT III |
Inrush VA | 30 VA |
Thermal Amperage | 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit) |
Switching Current | 5 mA (Signalling Circuit) |
Electrical Durability | 1.3 Mcycles 9 A AC-3 Less than or Equal to 440 V, 1.3 Mcycles 9 A AC-3e Less than or Equal to 440 V, 0.16 Mcycles 20 A AC-1 Less than or Equal to 690 V, 0.02 Mcycles 54 A AC-4 Less than or Equal to 440 V |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Mechanical Durability | 10 Mcycles |
Rated Breaking Capacity | 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V |
Max. Operating Watts | 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW 380 to (at 415V AC 50/60 Hz AC-3), 4 kW (at 440V AC 50/60 Hz AC-3), 4 kW (at 480V AC 50/60 Hz AC-3), 4 kW (at 500 to 600V AC 50/60 Hz AC-3), 4 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 415V AC 50/60 Hz AC-3e), 4 kW (at 440V AC 50/60 Hz AC-3e), 4 kW (at 480V AC 50/60 Hz AC-3e), 4 kW (at 500 to 600V AC 50/60 Hz AC-3e), 4 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Watts Loss | 1.3W |
Operating Time | 10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing) |
Rated Making Capacity | 110 A |
Hold VA | 4.5 VA |
Application | Motor Control, Resistive Load |
Reversing Capability | Non-Reversing |
Number of Auxillary Contacts | 1 |
NEMA Enclosure Rating | No Enclosure |
Frequency | 50/60 Hz |
Phase | Three |
Horsepower @ Three Phase - 600V AC | 5 hp |
Resistance Properties | Insulation Resistant |
Overall Depth | 1.97 in |
Full Load Current - Resistive | 20 A |
Horsepower @ Three Phase - 480V AC | 5 hp |
Number of Normally Open Main Contacts | 3 |
NEMA Enclosure Material | Not Applicable |
Horsepower @ Three Phase - 240V AC | 3 hp |
Includes Auxiliary Contacts | Yes |
Horsepower @ Single Phase - 240V AC | 1 1/2 hp |
Overall Width | 1.73 in |
Overall Height | 1.73 in |
Mounting Style | DIN Rail |
Terminal Connection Type | Screw Clamp Terminals |
Maximum Voltage Rating | 480V AC |
Coil Voltage | 200-208V AC |
Horsepower @ Single Phase - 120V AC | 1/2 hp |
Embedded Surge Suppressor | No |
Full Load Current - Inductive | 9 A |
Horsepower @ Three Phase - 208V AC | 2 hp |
Contactor Style | IEC |
Connections - Terminals | screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end |
Rated Operational Current | 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit, 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit |
Protective Treatment | TC IEC 60068, TC DIN 50016 |
Rated Impulse Withstand Voltage | 8 kV |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Flame Retardance | V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102 |
Minimum Switching Current | 5 mA for signalling circuit |
Poles Description | 3P |
Power Pole Contact Composition | 3 NO |
Product Or Component Type | Contactor |
Auxiliary Contacts Type | Instantaneous 1 NO |
Mechanical Robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6 |
Conventional Free Air Thermal Current | 20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit |
Device Application | Control |
Control Circuit Type | AC 50/60 Hz |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Utilisation Category | AC-3, AC-3e, AC-1, AC-4 |
Rated Short Time Withstand Current | 90 A 122°F (50°C) - 1 s for power circuit, 85 A 122°F (50°C) - 5 s for power circuit, 80 A 122°F (50°C) - 10 s for power circuit, 60 A 122°F (50°C) - 30 s for power circuit, 45 A 122°F (50°C) - 1 min for power circuit, 40 A 122°F (50°C) - 3 min for power circuit, 20 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit |
Non Overlap Distance | 0.02 in (0.5 mm) |
Average Impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
Inrush Power in VA | 30 VA (at 68°F (20°C)) |
Operating Altitude | 6561.68 ft (2000 m) without derating |
Contactor Application | Motor control, Resistive load |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz, Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz |
Product Certifications | CB Scheme, CCC, UL, CSA, EAC, CE, UKCA |
Hold-In Power Consumption in VA | 4.5 VA (at 68°F (20°C)) |
Minimum Switching Voltage | 17 V for signalling circuit |
Motor Power KW | 2.2 kW 220 to 230 V AC 50/60 Hz AC-3, 4 kW 380 to 415 V AC 50/60 Hz AC-3, 4 kW 440/690 V AC 50/60 Hz AC-3, 2.2 kW 220 to 230 V AC 50/60 Hz AC-3e, 4 kW 380 to 415 V AC 50/60 Hz AC-3e, 4 kW 440/690 V AC 50/60 Hz AC-3e, 2.2 kW 220 to 230 V AC 50/60 Hz AC-4, 4 kW 380 to 415 V AC 50/60 Hz AC-4, 4 kW 440/690 V AC 50/60 Hz AC-4 |
Control Circuit Voltage | 200 to 208 V AC 50/60 Hz |
Associated Fuse Rating | 25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660 |
IRMS Rated Making Capacity | 110 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947 |
Auxiliary Contact Composition | 1 NO |
Heat Dissipation | 1.3 W |
Maximum Operating Rate | 3600 cyc/h |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Mini Magnetic Contactor, 3 Poles, 208 V AC, 9 A, Reversing: No, SCHNEIDER, Mfr# LC1K0910L7
-3% / ea
with subscription
Free shipping will be applied on orders over $50
Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 200-208V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Non-Reversing, Overall Height 1.73 in, Overall Width 1.73 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$83.19
You must be logged in to post a review.
Reviews
There are no reviews yet.