Discount -3%

IEC Mini Magnetic Contactor, 3 Poles, 208 V AC, 9 A, Reversing: No, SCHNEIDER, Mfr# LC1K0910L7

-3% / ea
with subscription
Free shipping will be applied on orders over $50

Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 200-208V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Non-Reversing, Overall Height 1.73 in, Overall Width 1.73 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$83.19
Final shipping and tax calculated in checkout
Subtotal: $80.69 with subscription
Brand Name: SCHNEIDER
Mfr #: LC1K0910L7
Availability: Ships in 1 days
SKU: GRG2836626 Category:
Full Load Amps-Inductive9 A
ItemMiniature IEC Magnetic Contactor
ActionNon-Reversing
Full Load Amps-Resistive20 A
Number of Poles3
Coil Volts208 V AC
ReversingNo
HP @ 1 Phase - 120V1/2 hp
HP @ 1 Phase - 230V1-1/2
HP @ 1 Phase - 240V1 1/2 hp
Height1.73 in
HP @ 3 Phase - 208V2 hp
Width1.73 in
HP @ 3 Phase - 240V3 hp
HP @ 3 Phase - 575V5 hp
Depth1.97 in
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V5 hp
Aux. Contact Configuration1NO
Hz50/60
StandardsCSA, UKCA, UL Listed
Auxiliary Contact Form1NO
NEMA SizeNot Applicable
SeriesTeSys K
Impedance3 mOhm
Signalling Circuit FrequencyLess Than 400 Hz
Switching Voltage17 V (Signalling Circuit)
Environmental AttributesMercury Free, Toxic Heavy Metal Free
Fuse Amps25 A (Power Circuit), 10 A (Signalling Circuit)
Working Height6561.68 ft
Fire RatingUL 94 V1, NF F 16-101, NF F 16-102
Shock Resistance10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Operating Speed3600 cycles per hr
Control Circuit Voltage LimitsOperational: 0.85 to 1.1 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Overvoltage CategoryCAT III
Inrush VA30 VA
Thermal Amperage20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
Switching Current5 mA (Signalling Circuit)
Electrical Durability1.3 Mcycles 9 A AC-3 Less than or Equal to 440 V, 1.3 Mcycles 9 A AC-3e Less than or Equal to 440 V, 0.16 Mcycles 20 A AC-1 Less than or Equal to 690 V, 0.02 Mcycles 54 A AC-4 Less than or Equal to 440 V
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Mechanical Durability10 Mcycles
Rated Breaking Capacity110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V
Max. Operating Watts2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW 380 to (at 415V AC 50/60 Hz AC-3), 4 kW (at 440V AC 50/60 Hz AC-3), 4 kW (at 480V AC 50/60 Hz AC-3), 4 kW (at 500 to 600V AC 50/60 Hz AC-3), 4 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 415V AC 50/60 Hz AC-3e), 4 kW (at 440V AC 50/60 Hz AC-3e), 4 kW (at 480V AC 50/60 Hz AC-3e), 4 kW (at 500 to 600V AC 50/60 Hz AC-3e), 4 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Watts Loss1.3W
Operating Time10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing)
Rated Making Capacity110 A
Hold VA4.5 VA
ApplicationMotor Control, Resistive Load
Reversing CapabilityNon-Reversing
Number of Auxillary Contacts1
NEMA Enclosure RatingNo Enclosure
Frequency50/60 Hz
PhaseThree
Horsepower @ Three Phase - 600V AC5 hp
Resistance PropertiesInsulation Resistant
Overall Depth1.97 in
Full Load Current - Resistive20 A
Horsepower @ Three Phase - 480V AC5 hp
Number of Normally Open Main Contacts3
NEMA Enclosure MaterialNot Applicable
Horsepower @ Three Phase - 240V AC3 hp
Includes Auxiliary ContactsYes
Horsepower @ Single Phase - 240V AC1 1/2 hp
Overall Width1.73 in
Overall Height1.73 in
Mounting StyleDIN Rail
Terminal Connection TypeScrew Clamp Terminals
Maximum Voltage Rating480V AC
Coil Voltage200-208V AC
Horsepower @ Single Phase - 120V AC1/2 hp
Embedded Surge SuppressorNo
Full Load Current - Inductive9 A
Horsepower @ Three Phase - 208V AC2 hp
Contactor StyleIEC
Connections - Terminalsscrew clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end
Rated Operational Current9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit, 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Protective TreatmentTC IEC 60068, TC DIN 50016
Rated Impulse Withstand Voltage8 kV
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Flame RetardanceV1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102
Minimum Switching Current5 mA for signalling circuit
Poles Description3P
Power Pole Contact Composition3 NO
Product Or Component TypeContactor
Auxiliary Contacts TypeInstantaneous 1 NO
Mechanical RobustnessShocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Conventional Free Air Thermal Current20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit
Device ApplicationControl
Control Circuit TypeAC 50/60 Hz
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Utilisation CategoryAC-3, AC-3e, AC-1, AC-4
Rated Short Time Withstand Current90 A 122°F (50°C) - 1 s for power circuit, 85 A 122°F (50°C) - 5 s for power circuit, 80 A 122°F (50°C) - 10 s for power circuit, 60 A 122°F (50°C) - 30 s for power circuit, 45 A 122°F (50°C) - 1 min for power circuit, 40 A 122°F (50°C) - 3 min for power circuit, 20 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit
Non Overlap Distance0.02 in (0.5 mm)
Average Impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Inrush Power in VA30 VA (at 68°F (20°C))
Operating Altitude6561.68 ft (2000 m) without derating
Contactor ApplicationMotor control, Resistive load
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz, Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz
Product CertificationsCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
Hold-In Power Consumption in VA4.5 VA (at 68°F (20°C))
Minimum Switching Voltage17 V for signalling circuit
Motor Power KW2.2 kW 220 to 230 V AC 50/60 Hz AC-3, 4 kW 380 to 415 V AC 50/60 Hz AC-3, 4 kW 440/690 V AC 50/60 Hz AC-3, 2.2 kW 220 to 230 V AC 50/60 Hz AC-3e, 4 kW 380 to 415 V AC 50/60 Hz AC-3e, 4 kW 440/690 V AC 50/60 Hz AC-3e, 2.2 kW 220 to 230 V AC 50/60 Hz AC-4, 4 kW 380 to 415 V AC 50/60 Hz AC-4, 4 kW 440/690 V AC 50/60 Hz AC-4
Control Circuit Voltage200 to 208 V AC 50/60 Hz
Associated Fuse Rating25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
IRMS Rated Making Capacity110 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947
Auxiliary Contact Composition1 NO
Heat Dissipation1.3 W
Maximum Operating Rate3600 cyc/h
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Mini Magnetic Contactor
#3 Poles
#208 V AC
#9 A
#Reversing: No
#SCHNEIDER
#Mfr LC1K0910L7
#SCHNEIDER
#GRG2836626
#mfr:LC1K0910L7
#part number:LC1K0910L7
#pn:LC1K0910L7
#part code:LC1K0910L7
#item number:LC1K0910L7
#product code:LC1K0910L7
#manufacturer number:LC1K0910L7
#manufacturers part number:LC1K0910L7
#mfn:LC1K0910L7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!