Full Load Amps-Inductive | 9 A |
Item | Miniature IEC Magnetic Contactor |
Full Load Amps-Resistive | 20 A |
Action | Reversing |
Number of Poles | 3 |
Coil Volts | 240 V AC |
Reversing | Yes |
HP @ 1 Phase - 230V | 1-1/2 |
HP @ 1 Phase - 120V | 1/2 hp |
Height | 3.54 in |
HP @ 1 Phase - 240V | 1 1/2 hp |
HP @ 3 Phase - 208V | 2 hp |
Width | 3.54 in |
Depth | 1.97 in |
HP @ 3 Phase - 575V | 5 hp |
HP @ 3 Phase - 240V | 3 hp |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 5 hp |
Aux. Contact Configuration | 1NC |
Hz | 50/60 |
Standards | BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660 |
Auxiliary Contact Form | 1NC |
Frame / Series / Class / Code | TeSys |
NEMA Size | Not Applicable |
Series | TeSys K |
Overvoltage Category | CAT III |
Operating Time | 10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Rated Making Capacity | 110 A |
Operating Speed | 3600 cycles per hr |
Thermal Amperage | 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit) |
Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
Net Weight | 0.39 kg |
Electrical Durability | 0.18 Mcycles (20 A, AC-1, Less than 440 V), 1.3 Mcycles (9 A, AC-3, Less than 440 V), 1.3 Mcycles (9 A, AC-3e, Less than 440 V) |
Features | Preassembled with Reversing Power Busbar |
Switching Current | 5 mA (Signalling Circuit) |
Rated Short-Time Withstand Current | 90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 20 A (at 50°C for 15 min Power Circuit) |
Watts Loss | 1.3W |
IP Rating | IP20 |
Max. Operating Watts | 2.2 kW (at 220 to 230V AC 50/60 Hz), 4 kW (at 380 to 415VAC 50/60 Hz), 4 kW (at 440V AC 50/60 Hz), 4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz) |
Hold VA | 4.5 VA |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Mechanical Durability | 5 Mcycles |
Inrush VA | 30 VA |
Rated Insulation Volts | 600/690V |
Rated Voltage | 690V AC |
Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
Control Circuit Voltage Limits | Operational: 0.85 to 1.1 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
Signalling Circuit Frequency | Less Than 400 Hz |
Impedance | 3 mOhm |
Mounts On | Plate, Rail |
Working Height | 6561.68 ft |
Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
Rated Breaking Capacity | 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V |
Application | Motor Control, Resistive Load |
Switching Voltage | 17 V (Signalling Circuit) |
Impulse Withstand Voltage | 8 kV |
Tightening Torque | 0.8 to 1.3 Nm |
Electrical Connection | Screw Clamp Terminals |
NEMA Enclosure Rating | No Enclosure |
Electrical Operating Durability | 1,300,000, 180,000 |
Full Load Current - Inductive | 9 A |
Mounting Style | DIN Rail, Plate |
Horsepower @ Three Phase - 480V AC | 5 hp |
Number of Normally Open Main Contacts | 3 |
Reversing Capability | Reversing |
Resistance Properties | Insulation Resistant |
Full Load Current - Resistive | 20 A |
Maximum Voltage Rating | 690V AC |
Horsepower @ Three Phase - 600V AC | 5 hp |
Horsepower @ Single Phase - 240V AC | 1 1/2 hp |
Includes Auxiliary Contacts | Yes |
Minimum Operating Temperature | -13 Degrees F |
Overall Depth | 2.24 in |
Frequency | 50/60 Hz |
Mechanical Operating Durability | 5,000,000 |
Coil Voltage | 230-240V AC |
Number of Auxillary Contacts | 1 |
Maximum Operating Temperature | 122 Degrees F |
Horsepower @ Single Phase - 120V AC | 1/2 hp |
Horsepower @ Three Phase - 208V AC | 2 hp |
Overall Height | 2.28 in |
Horsepower @ Three Phase - 240V AC | 3 hp |
Contactor Style | IEC |
Overall Width | 3.54 in |
NEMA Enclosure Material | Not Applicable |
Terminal Connection Type | Screw Clamp Terminals |
Embedded Surge Suppressor | No |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Mini Magnetic Contactor, 3 Poles, 240 V AC, 9 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2K0901U7
$177,99
Free shipping will be applied on orders over $50
Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 230-240V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Reversing, Overall Height 2.28 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC
Out of stock
You must be logged in to post a review.
Reviews
There are no reviews yet.