Item | Motor Management System |
Current Range | 5 to 100A |
Control Voltage | 24V DC |
Width | 3.58 in |
Interface | CANopen |
Operating Voltage | 690V AC |
Height | 2.4 in |
Depth | 4.82 in |
Standards | CCC, CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, nABS, nATEX, nBV, nC-tick, nCSA, nDNV, nEAC, nGL, nKERI, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508 |
For Use With | Short Circuit Protection And A Contactor |
Protective Treatment | 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068 |
[Uimp] Rated Impulse Withstand Voltage | 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 || 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1 |
Product Name | TeSys T |
Compatibility Code | LTMR |
Network And Machine Diagnosis Type | motor control command recording || trip context information || starting current and time || event recording || fault recording || remaining operating time before overload tripping || phase fault and earth fault trip counters || waiting time after overload tripping || running hours counter/operating time || trip history information |
Bus Type | CANopen ISO 1198 1 to 127 10 to 1000 kbit/s, SUB-D 9 4 twisted shielded pairs cable || CANopen ISO 1198 1 to 127 10 to 1000 kbit/s, terminal block 4 twisted shielded pairs cable |
Protection Type | thermal protection || reverse polarity protection || phase unbalance || phase failure || overload (long time) || thermal overload protection || load fluctuation || power factor variation || earth-leakage protection || locked rotor || overload |
Operating Altitude | <= 6561.68 ft (2000 m) without derating |
Current State 0 Guaranteed | logic input < 5 V <= 15 mA 5 ms |
Contacts Type And Composition | 1 NO + 1 NC fault signal || 3 NO |
Input Current | 7 mA |
Electromagnetic Compatibility | electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 |
Web Services | web server |
Connections - Terminals | control circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)solid without cable end |
[Ui] Rated Insulation Voltage | 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508 |
Measurement Current | 5-100 A |
Current Consumption | 56 to 127 mA |
Device Application | equipment monitoring and control |
Associated Fuse Rating | 4 A gG output || 0.5 A gG control circuit |
Tightening Torque | control circuit 0.5-0.6 N.m flat 3 mm |
Overvoltage Category | III |
Load Current | 5 A 250 V AC logic output || 5 A 30 V DC logic output |
Maximum Operating Frequency | 2 Hz |
Short-Circuit Withstand | 100 kA conforming to EN/IEC 60947-4-1 |
Product Certifications | CCC || C-tick || ABS || RINA || KERI || EAC || ATEX || UL || NOM || RMRoS || LROS (Lloyds register of shipping) || CSA || GL || BV || DNV |
Communication Port Protocol | CANopen |
Permissible Power | 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output) |
Device Short Name | LTMR |
[Us] Rated Supply Voltage | 24 V DC |
Supply Voltage Limits | 20.4-26.24 V DC |
Connection Pitch | 5.08 mm |
Maximum Operating Rate | 1800 cyc/h |
Pollution Degree | 3 |
Current State 1 Guaranteed | logic input < 15 V 2 to 15 mA 15 ms |
Fire Resistance | 650°C EN/IEC 60695-2-12 || 960°C UL 94 |
Ip Degree Of Protection | IP20 |
Logic Input Number | 6 |
Ambient Air Temperature For Storage | -40-80°C |
Metering Type | imbalance current || earth-fault current || temperature || phase current I1, I2, I3 RMS || average current Iavg |
Ambient Air Temperature For Operation | -20-60°C |
Range | TeSys |
Product Or Component Type | motor controller |
Measurement Accuracy | 5 to 15 % earth fault current internal measurement || 1 % voltage 100 to 830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 5 % active and reactive power || 0,02 current |
Mechanical Robustness | vibrations mounted on symmetrical rail1 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 |
Number of Normally Open Contacts | 4 |
Overall Height | 2.4 in |
Minimum Current Rating | 5 A |
Number of Normally Closed Contacts | 1 |
Compatible with Series | TeSys T |
Maximum Current Rating | 100 A |
Overall Depth | 4.82 in |
Overall Width | 3.58 in |
Number of Contacts Included | 5 |
Country of Origin (subject to change) | China |
Package Quantity | 1 |
Motor Manager, CANopen, 24VDC, 5-100A, SCHNEIDER ELECTRIC, Mfr# LTMR100CBD
$874,99
Free shipping will be applied on orders over $50
Motor Management System, Number of Normally Open Contacts 4, Number of Normally Closed Contacts 1, Number of Contacts Included 5, Operating Voltage 690V AC, Control Voltage 24V DC, Interface CANopen, Compatible with Series TeSys T, Overall Width 3.58 in, Standards CCC, CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, nABS, nATEX, nBV, nC-tick, nCSA, nDNV, nEAC, nGL, nKERI, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508, Overall Height 2.4 in, Overall Depth 4.82 in, Maximum Current Rating 100 A