Item | Power Distribution Block |
Number of Poles | 1 |
Max. Amps | 85 A |
Primary Connections/Pole | 1 |
Primary Wire Range (AWG) | 14 to 4 AWG |
Secondary Connection/Pole | 1 |
Secondary Wire Range (AWG) | 14 to 4 AWG |
Power Distribution Block Design | Open |
Voltage Rating | 600V AC/DC |
Depth | 2.81 in |
Length | 3.08 in |
Standards | CSA Class 6228-01, UL 1953 |
Width | 1.05 in |
Length (Straight Wireway) | 3.08 in |
For Conductor Material | Aluminum |
For Load Copper Wire Size - Maximum | 4 AWG |
Load Side Wire Range | 14 AWG - 4 AWG |
For Load Copper Wire Size - Minimum | 14 AWG |
Line Side Wire Size Range | 14 AWG - 4 AWG |
Terminal Material | Aluminum |
Line Connections/Pole | 1 |
Load Connections/Pole | 1 |
Maximum Voltage | 1,000 V AC/DC |
Maximum Current - Aluminum Conductor | 85 A |
Housing Material | GFPC |
Overall Depth | 2.81 in |
For Line Copper Wire Size - Maximum | 4 AWG |
Secondary Wire Range | 14 to 4 AWG |
Overall Width | 1.05 in |
For Load Aluminum Wire Size - Maximum | 4 AWG |
Overall Length | 3.08 in |
UL 94 Flammability Rating | V-0 |
For Line Aluminum Wire Size - Minimum | 14 AWG |
Primary Wire Range | 14 to 4 AWG |
For Line Copper Wire Size - Minimum | 14 AWG |
Line Side Connection Type | Lug |
For Load Aluminum Wire Size - Minimum | 14 AWG |
RoHS Compliant | Yes |
Housing Color | Black |
Load Side Connection Type | Lug |
Maximum Current - Copper Conductor | 85 A |
Number of Circuits | 1 |
For Line Aluminum Wire Size - Maximum | 4 AWG |
Includes | Polycarbonate Safety Covers |
Mounting | Direct Screw Mount |
Features | Flammability Rating 94 V-0, GFPC Insulators, 1 inch through air and 2 inches over surface spacing available |
Max. Operating Temp. | 80°C |
Short Circuit Rating (Class RK1) | 60 kA |
Torque Rating (Secondary) | #4-#6 35, #8 25, #10-#14 20 |
Wire Range (Secondary) | #4-#14 |
Wire Range (Primary) | #4-#14 |
Short Circuit Rating (Class T) | 100 kA |
Short Circuit Rating (Class CC) | 30 kA |
APPROVALS & STANDARDS | UL Listed to subject 1953, File E352417 unless noted otherwise, CSA Certified Class 6228 01 |
Hole Diameter (Secondary) | 0.25 in |
Hex/Screw Size & Type (Secondary) | 1/4-28 x .38 |
Short Circuit Rating (Class RK5) | 30 kA |
Hole Diameter (Primary) | 0.25 in |
Short Description | MPDB UL1953 AL MINI 1000V 85A 1-pole 1 #4-#14 in-1 #4-#14 out Box/Box |
Product Length | 3.08 in |
Item Description (ERP) | PWR DIS BLK AL MINI 85A 1P 1 |
Rated voltage DC UL | 1000 V |
APPLICATIONS | Splicing cables, Splitting primary power into secondary circuits, Fixed junction tap-off points. |
Number of Openings per Pole (Primary) | 1 |
Connector Type (Primary) | Box |
Hex/Screw Size & Type (Primary) | 1/4-28 x .38 |
Torque Rating (Primary) | #4-#6 35, #8 25, #10-#14 20 |
Short Circuit Rating (Standalone) | 10 kA |
Connector Type (Secondary) | Box |
Rated voltage AC UL | 1000 V |
Short Circuit Rating (Class G) | 60 kA |
Short Circuit Rating (Class L) | 100 kA |
Product Width | 1.05 in |
Number of Openings per Pole (Secondary) | 1 |
Installation Mounting | Direct Screw Mount |
Product Height | 2.81 in |
Body/Insulating Material | GFPC |
Short Circuit Rating (Class J) | 100 kA |
Connector Material | Tin-plated Aluminum |
Country of Origin (subject to change) | Mexico |
Package Quantity | 1 |
Pwr Dist Block, 85A, 1P, 14-4 AWG, 600VAC/DC, MERSEN, Mfr# MPDB63101
-3% / ea
with subscription
Free shipping will be applied on orders over $50
Power Distribution Block, For Conductor Material Aluminum, Line Connections/Pole 1, For Line Copper Wire Size - Minimum 14 AWG, For Line Copper Wire Size - Maximum 4 AWG, Load Connections/Pole 1, For Load Copper Wire Size - Minimum 14 AWG, For Load Copper Wire Size - Maximum 4 AWG, Maximum Current - Copper Conductor 85 A, Maximum Voltage 1,000 V AC/DC, Mounting Type Surface Mount, Number of Poles 1, Overall Depth 2.81 in, Overall Length 3.08 in, Overall Width 1.05 in
9999 in stock
Must order in multiples of 1
Subtotal:
$9.25
You must be logged in to post a review.
Reviews
There are no reviews yet.