Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC2D18F7
Availability: Ships in 5 days
SKU: GRG0568480 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive18 A
ActionReversing
Full Load Amps-Resistive32 A
Number of Poles3
Coil Volts110 V AC
HP @ 1 Phase - 240V3 hp
Height77 mm
HP @ 3 Phase - 208V5 hp
Width90 mm
HP @ 3 Phase - 575V15 hp
Depth86 mm
HP @ 3 Phase - 240V5 hp
HP @ 3 Phase - 480V10 hp
Aux. Contact Configuration1NO/1NC
SeriesLC2D
StandardsCSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, DNV, CSA, CCC, UL, GL, LROS, BV, RINA, GOST, UKCA, TH IEC 60068-2-30
ApplicationMotor Control, Resistive Load
FeaturesWithout Built-In Suppressor Module, Preassembled with Reversing Power Busbar
IP RatingIP20
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Non-Overlap Time1.5 ms
Operating Time12 to 22 ms (Closing), 4 to 19 ms (Opening)
Rated Breaking Capacity300 A @ 440V
Includes Protective CoverYes
Max. Operating Watts4 kW (at 220 to 230V AC 50 Hz), 7.5 kW (at 380 to 400V AC 50 Hz), 9 kW (at 415 to 440V AC 50 Hz), 10 kW (at 500V AC 50 Hz), 10 kW (at 660 to 690V AC 50 Hz)
Working HeightUp to 9842.52 ft
Mounts OnPlate, Rail
Electrical Durability1.65 Mcycles (18 A, AC-3, Less than 440 V), 1 Mcycles (32 A, AC-1, Less than 440 V)
Impedance2.5 mOhm
Signalling Circuit Frequency25 to 400 Hz
Max. Temperature850°C
Fuse Amps10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit)
Inrush VA70 VA
Rated Voltage690V AC, 300V DC
Operating Speed3600 cycles per hr
Tightening Torque1.7 Nm (Control Circuit), 1.7 to 2.5 Nm (Power Circuit)
Overvoltage CategoryCAT III
Shock Resistance15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Mechanical Durability15 Mcycles
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit)
Rated Insulation Volts600/690V
Electrical ConnectionScrew Clamp Terminals
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Net Weight0.707 kg
Impulse Withstand Voltage6 kV
Switching Voltage17 V (Signalling Circuit)
Watts Loss2 to 3W
Thermal Amperage10 A (at 60°C Signalling Circuit), 32 A (at 60°C Power Circuit)
Hold VA7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Switching Current5 mA (Signalling Circuit)
Rated Short-Time Withstand Current40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Fire RatingUL 94 V1
Country of Origin (subject to change)Indonesia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#110 V AC
#18 A
#SCHNEIDER ELECTRIC
#Mfr LC2D18F7
#SCHNEIDER ELECTRIC
#GRG0568480
#mfr:LC2D18F7
#part number:LC2D18F7
#pn:LC2D18F7
#part code:LC2D18F7
#item number:LC2D18F7
#product code:LC2D18F7
#manufacturer number:LC2D18F7
#manufacturers part number:LC2D18F7
#mfn:LC2D18F7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!