Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 25 A |
Action | Reversing |
Full Load Amps-Resistive | 25 A |
Number of Poles | 4 |
Coil Volts | 120 V AC |
Reversing | Yes |
Height | 3.35 in |
Width | 3.54 in |
Depth | 3.54 in |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Series | TeSys Deca |
NEMA Size | Not Applicable |
Standards | CB, CCC, CSA, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EAC, EN 60947-4-1, EN 60947-5-1, EU-RO-MR by DNV-GL, GB/T 14048.4, IEC 60947-4-1, IEC 60947-5-1, UKCA, UL 60947-5-1, UL Listed, UL 60947-4-1 |
Auxiliary Contact Form | 1NO/1NC |
Frame / Series / Class / Code | TeSys |
Application | Resistive Load |
Features | Without Built-In Suppressor Module, Preassembled with Prewired Power Connections |
Overall Width | 3.54 in |
Overall Height | 3.35 in |
Rated Insulation Volts | 600/690V |
Mechanical Durability | 15 Mcycles |
Mounts On | Plate, Rail |
Switching Voltage | 17 V (Signalling Circuit) |
Electrical Durability | 0.8 Mcycles (25 A, AC-1, Less than 690 V) |
Impedance | 2.5 mOhm |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 60°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz) |
Impulse Withstand Voltage | 6 kV |
Fire Rating | UL 94 V1 |
Watts Loss | 2 to 3W |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit) |
Signalling Circuit Frequency | 25 to 400 Hz |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
IP Rating | IP20 |
Inrush VA | 70 VA |
Overvoltage Category | CAT III |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Working Height | Up to 9842.52 ft |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Fuse Amps | 10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit) |
Rated Breaking Capacity | 250 A @ 440V |
Includes Protective Cover | Yes |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Switching Current | 5 mA (Signalling Circuit) |
Rated Voltage | 690V AC, 300V DC |
Non-Overlap Time | 1.5 ms |
Net Weight | 0.73 kg |
Operating Speed | 3600 cycles per hr |
Tightening Torque | 1.7 Nm (Control Circuit), 1.7 to 2.5 Nm (Power Circuit) |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Max. Temperature | 850°C |
Rated Short-Time Withstand Current | 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Rated Making Capacity | 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Electrical Connection | Screw Clamp Terminals |
Electrical Operating Durability | 800,000 |
Terminal Connection Type | Screw Clamp Terminals |
Maximum Voltage Rating | 690V AC |
Mounting Style | DIN Rail, Plate |
Mechanical Operating Durability | 15,000,000 |
Includes Auxiliary Contacts | Yes |
NEMA Enclosure Material | Not Applicable |
Number of Normally Open Main Contacts | 4 |
Reversing Capability | Reversing |
Minimum Operating Temperature | -40 Degrees F |
Maximum Operating Temperature | 140 Degrees F |
Number of Auxillary Contacts | 2 |
Embedded Surge Suppressor | No |
NEMA Enclosure Rating | No Enclosure |
Overall Depth | 3.54 in |
Contactor Style | IEC |
Full Load Current - Inductive | 25 A |
Resistance Properties | Fire Resistant, Insulation Resistant |
Full Load Current - Resistive | 25 A |
Coil Voltage | 120V AC |
Frequency | 50/60 Hz |
Inrush Power in VA | 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
Flame Retardance | V1 conforming to UL 94 |
Climatic Withstand | IACS E10, IEC 60947-1 Annex Q category D |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
IRMS Rated Making Capacity | 250 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
Protective Treatment | TH IEC 60068-2-30 |
Average Impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1, 40 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 25 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Minimum Switching Current | 5 mA for signalling circuit |
Power Pole Contact Composition | 4 NO |
Mounting Support | Plate, Rail |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
Ambient Air Temperature For Operation | -40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating |
Interlocking Type | Mechanical |
Front Cover | With |
Coil Technology | Without built-in suppressor module |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Product Certifications | UL, CSA, CCC, EAC, UKCA, CB, EU-RO-MR by DNV-GL |
Heat Dissipation | 2 to 3 W 50/60 Hz |
Minimum Switching Voltage | 17 V for signalling circuit |
Ambient Air Temperature For Storage | -76 to 176°F (-60 to 80°C) |
Rated Short Time Withstand Current | 30 A 104°F (40°C) - 10 min for power circuit, 61 A 104°F (40°C) - 1 min for power circuit, 105 A 104°F (40°C) - 10 s for power circuit, 210 A 104°F (40°C) - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
Utilisation Category | AC-1 |
Control Circuit Type | AC 50/60 Hz |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Pollution Degree | 3 |
IP Degree Of Protection | IP20 front face IEC 60529 |
Product Name | TeSys D, TeSys Deca |
Mechanical Robustness | Vibrations contactor open2 Gn, 5 to 300 Hz, Vibrations contactor closed4 Gn, 5 to 300 Hz, Shocks contactor open10 Gn for 11 ms, Shocks contactor closed15 Gn for 11 ms |
Control Circuit Voltage | 120 V AC 50/60 Hz |
Poles Description | 4P |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Device Presentation | Preassembled, with prewired power connections |
Product Or Component Type | Changeover contactor |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Rated Operational Current | 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC |
Power Dissipation Per Pole | 1.56 W AC-1 |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL |
Auxiliary Contact Composition | 1 NO + 1 NC |
Hold-In Power Consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C)) |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit, 25 A (at 140°F (60°C)) for power circuit |
Connections - Terminals | Power circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)flexible without cable end, Power circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?)flexible without cable end, Power circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)flexible with cable end, Power circuit screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?)flexible with cable end, Power circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)solid, Power circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?)solid, Control circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)flexible without cable end, Control circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?)flexible without cable end, Control circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)flexible with cable end, Control circuit screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?)flexible with cable end, Control circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)solid, Control circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?)solid |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 4 Poles, 120 V AC, 25 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2DT25G7
$432,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 4, Full Load Current - Inductive 25 A, Full Load Current - Resistive 25 A, Reversing Capability Reversing, Overall Height 3.35 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Maximum Voltage Rating 690V AC
9999 in stock
Must order in multiples of 1
Subtotal:
$432.99
You must be logged in to post a review.