Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 9 A |
Action | Reversing |
Full Load Amps-Resistive | 20 A |
Number of Poles | 3 |
Coil Volts | 24 V AC |
Reversing | Yes |
Height | 2.28 in |
Width | 3.54 in |
Depth | 2.24 in |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | None |
Hz | 50/60 |
Auxiliary Contact Form | 1NO |
Series | TeSys K |
NEMA Size | Not Applicable |
Standards | BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660 |
Frame / Series / Class / Code | TeSys |
Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
Max. Operating Watts | 2.2 kW (at 220 to 230V AC 50/60 Hz), 4 kW (at 380 to 415VAC 50/60 Hz), 4 kW (at 440V AC 50/60 Hz), 4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz) |
Electrical Connection | Screw Clamp Terminals |
Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
Switching Voltage | 17 V (Signalling Circuit) |
Electrical Durability | 0.18 Mcycles (20 A, AC-1, Less than 440 V), 1.3 Mcycles (9 A, AC-3, Less than 440 V), 1.3 Mcycles (9 A, AC-3e, Less than 440 V) |
Operating Speed | 3600 cycles per hr |
Rated Voltage | 690V AC |
Operating Time | 10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening) |
Features | Preassembled with Reversing Power Busbar |
Switching Current | 5 mA (Signalling Circuit) |
Hold VA | 4.5 VA |
Inrush VA | 30 VA |
Rated Short-Time Withstand Current | 90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 20 A (at 50°C for 15 min Power Circuit) |
Impedance | 3 mOhm |
Thermal Amperage | 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit) |
Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
Overvoltage Category | CAT III |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Rated Insulation Volts | 600/690V |
Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
IP Rating | IP20 |
Watts Loss | 1.3W |
Tightening Torque | 0.8 to 1.3 Nm |
Mechanical Durability | 5 Mcycles |
Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
Rated Breaking Capacity | 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V |
Mounts On | Plate, Rail |
Net Weight | 0.39 kg |
Application | Motor Control, Resistive Load |
Signalling Circuit Frequency | Less Than 400 Hz |
Working Height | 6561.68 ft |
Rated Making Capacity | 110 A |
Impulse Withstand Voltage | 8 kV |
Overall Height | 2.28 in |
NEMA Enclosure Rating | No Enclosure |
Terminal Connection Type | Screw Clamp Terminals |
Overall Depth | 2.24 in |
NEMA Enclosure Material | Not Applicable |
Resistance Properties | Insulation Resistant |
Maximum Voltage Rating | 690V AC |
Full Load Current - Resistive | 20 A |
Mechanical Operating Durability | 5,000,000 |
Maximum Operating Temperature | 122 Degrees F |
Reversing Capability | Reversing |
Mounting Style | DIN Rail, Plate |
Overall Width | 3.54 in |
Full Load Current - Inductive | 9 A |
Includes Auxiliary Contacts | Yes |
Embedded Surge Suppressor | No |
Electrical Operating Durability | 1,300,000, 180,000 |
Minimum Operating Temperature | -13 Degrees F |
Number of Auxillary Contacts | 1 |
Contactor Style | IEC |
Frequency | 50/60 Hz |
Number of Normally Open Main Contacts | 3 |
Coil Voltage | 24V AC |
Heat Dissipation | 1.3 W |
Ambient Air Temperature For Operation | -13 to 122°F (-25 to 50°C) |
Control Circuit Type | AC 50/60 Hz |
Mechanical Robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6 |
Auxiliary Contact Composition | 1 NO |
Motor Power KW | 2.2 kW 220 to 230 V AC 50/60 Hz, 4 kW 380 to 415 V AC 50/60 Hz, 4 kW 440/690 V AC 50/60 Hz |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Flame Retardance | V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102 |
Rated Short Time Withstand Current | 90 A 122°F (50°C) - 1 s for power circuit, 85 A 122°F (50°C) - 5 s for power circuit, 80 A 122°F (50°C) - 10 s for power circuit, 60 A 122°F (50°C) - 30 s for power circuit, 45 A 122°F (50°C) - 1 min for power circuit, 40 A 122°F (50°C) - 3 min for power circuit, 20 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit |
Auxiliary Contacts Type | Instantaneous 1 NO |
IP Degree Of Protection | IP20 VDE 0106 |
Mounting Support | Rail, Plate |
Minimum Switching Current | 5 mA for signalling circuit |
IRMS Rated Making Capacity | 110 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947 |
Utilisation Category | AC-3, AC-3e, AC-4, AC-1 |
Conventional Free Air Thermal Current | 20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit |
Connections - Terminals | screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end |
Control Circuit Voltage | 24 V AC 50/60 Hz |
Operating Altitude | 6561.68 ft (2000 m) without derating |
Maximum Operating Rate | 3600 cyc/h |
Product Certifications | CB Scheme, CCC, UL, CSA, EAC, CE, UKCA |
Rated Operational Current | 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit, 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit |
Product Or Component Type | Reversing contactor |
Inrush Power in VA | 30 VA (at 68°F (20°C)) |
Ambient Air Temperature For Storage | -58 to 176°F (-50 to 80°C) |
Device Application | Control |
Rated Operational Voltage | Power circuit 690 V AC 50/60 Hz, Signalling circuit Less than or Equal to 690 V AC 50/60 Hz |
Non Overlap Distance | 0.02 in (0.5 mm) |
Minimum Switching Voltage | 17 V for signalling circuit |
Poles Description | 3P |
Interlocking Type | Mechanical |
Protective Treatment | TC IEC 60068, TC DIN 50016 |
Hold-In Power Consumption in VA | 4.5 VA (at 68°F (20°C)) |
Average Impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
Contactor Application | Motor control, Resistive load |
Associated Fuse Rating | 25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660 |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Power Pole Contact Composition | 3 NO |
Rated Insulation Voltage | Power circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14 |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 V AC, 9 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2K0910B7
-3% / ea
with subscription
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Reversing, Overall Height 2.28 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC, Maximum Voltage Rating 690V AC
9999 in stock
Must order in multiples of 1
Subtotal:
$184.99
You must be logged in to post a review.
Reviews
There are no reviews yet.