Item | Stdcntrlunitcl103Ph 312A 24Vac |
Overload Relay Amp Setting | 3 to 12 A |
Coil Volts | 24V AC |
Width | 45 mm |
Features | Protection against phase failure and phase imbalance, Protection against overload and short-circuit, Manual reset, Earth fault protection, Free of Halogen, Mercury & Pvc, Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock & Vibration |
Standards | EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier, CE, CCC, EAC, ASEFA, ATEX, Marine |
Height | 66 mm |
Hz | 40 to 60 Hz |
Depth | 60 mm |
Weight | 0.135 kg |
Operating Voltage | 690V AC |
Resistance To Electrostatic Discharge | 8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2 |
Typical Current Consumption | 140 mA 24 V AC I maximum while closing with LUB12, 220 mA 24 V AC I maximum while closing with LUB32, 220 mA 24 V AC I maximum while closing with LUB38, 70 mA 24 V AC I rms sealed with LUB12, 90 mA 24 V AC I rms sealed with LUB32, 90 mA 24 V AC I rms sealed with LUB38 |
Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
Protective Treatment | TH IEC 60068 |
Utilisation Category | AC-44, AC-41, AC-43 |
Product Specific Application | Basic protection requirements for motor starters: overload and short-circuit |
Rated Impulse Withstand Voltage | 6 kV IEC 60947-6-2 |
Motor Power KW | 5.5 kW 400 to 440 V AC 50/60 Hz, 5.5 kW 500 V AC 50/60 Hz, 9 kW 690 V AC 50/60 Hz |
Phase Failure Sensitivity | Yes |
Tripping Threshold | 14.2 x Ir +/- 20% |
Rated Insulation Voltage | 690 V IEC 60947-6-2, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1 |
IP Degree Of Protection | IP20 front panel and wired terminals IEC 60947-1, IP20 other faces IEC 60947-1, IP40 front panel outside connection zone IEC 60947-1 |
Control Circuit Voltage Limits | 20 to 26.5 V AC 24 V in operation, 14.5 V AC 24 V drop-out |
Compatibility Code | LUCA |
Rated Operational Voltage | 690 V AC |
Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 |
Ambient Air Temperature For Operation | -13 to 158°F (-25 to 70°C) |
Product Name | TeSys Ultra |
Load Type | 3-phase motor self-cooled |
Vibration Resistance | 2 gn 5 to 300 Hz power poles open IEC 60068-2-6, 4 gn 5 to 300 Hz power poles closed IEC 60068-2-6 |
Product Or Component Type | Standard control unit |
Thermal Overload Class | Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) IEC 60947-6-2, Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) UL 508 |
Product Certifications | CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine |
Device Application | Motor control, Motor protection |
Control Circuit Voltage | 24 V AC |
Shock Resistance | 10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27 |
Fixing Mode | Plug-in front face) |
Operating Time | 35 ms opening with LUB12 control circuit, 35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit, 70 ms closing with LUB12 control circuit, 70 ms closing with LUB32 control circuit, 70 ms closing with LUB38 control circuit |
Fire Resistance | 1760°F (960°C) parts supporting live components IEC 60695-2-12, 1202°F (650°C) IEC 60695-2-12 |
Ambient Air Temperature For Storage | -40 to 185°F (-40 to 85°C) |
Resistance To Radiated Fields | 9.14 V/m (10 V/m) 3 IEC 61000-4-3 |
Operating Altitude | 6561.68 ft (2000 m) |
Heat Dissipation | 2 W control circuit with LUB12, 3 W control circuit with LUB32, 3 W control circuit with LUB38 |
Product Compatibility | Power base LUB12, Power base LUB32, Power base LUB38, Power base LUB120, Power base LUB320, Power base LUB380, Reversing contactor breaker LU2B12B, Reversing contactor breaker LU2B32B |
Non-Dissipating Shock Wave | 1 kV serial mode IEC 60947-6-2, 2 kV common mode IEC 60947-6-2 |
Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
Immunity To Microbreaks | 3 ms |
Immunity To Voltage Dips | 70% / 500 ms IEC 61000-4-11 |
Main Function Available | Protection against phase failure and phase imbalance, Protection against overload and short-circuit, Manual reset, Earth fault protection |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
Stdcntrlunitcl103Ph 312A 24Vac, SCHNEIDER ELECTRIC, Mfr# LUCA12B