ItemAdvcntrlunitcl101Ph 312A 24Vdc
Overload Relay Amp Setting3 to 12 A
Coil Volts24V DC
Width45 mm
Depth60 mm
FeaturesEarth fault protection, Protection against phase failure and phase imbalance, Manual reset, Protection against overload and short-circuit, Free of Halogen, Mercury & Pvc, Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock & Vibration
StandardsEN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier, CE, CCC, EAC, ASEFA, ATEX, Marine
Height66 mm
Hz40 to 60 Hz
Operating Voltage690V AC
Ambient Air Temperature For Operation-13 to 158°F (-25 to 70°C)
Resistance To Fast Transients2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
Product Specific ApplicationBasic protection and advanced functions, communication
Shock Resistance10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27
Load TypeSingle-phase motor
Resistance To Electrostatic Discharge8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2
Product CertificationsCE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
Product Or Component TypeAdvanced control unit
IP Degree Of ProtectionIP20 front panel and wired terminals IEC 60947-1, IP20 other faces IEC 60947-1, IP40 front panel outside connection zone IEC 60947-1
Fire Resistance1760°F (960°C) parts supporting live components IEC 60695-2-12, 1202°F (650°C) IEC 60695-2-12
Utilisation CategoryAC-41, AC-43, AC-44
Heat Dissipation2 W control circuit with LUB12, 3 W control circuit with LUB32, 3 W control circuit with LUB38
Compatibility CodeLUCC
ResetManual reset
Rated Insulation Voltage690 V IEC 60947-6-2, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
Operating Time35 ms opening with LUB12 control circuit, 35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit, 70 ms closing with LUB12 control circuit, 70 ms closing with LUB32 control circuit, 70 ms closing with LUB38 control circuit
Resistance To Radiated Fields9.14 V/m (10 V/m) 3 IEC 61000-4-3
Control Circuit Voltage24 V DC
Product NameTeSys Ultra
Main Function AvailableEarth fault protection, Protection against phase failure and phase imbalance, Manual reset, Protection against overload and short-circuit
Tripping Threshold14.2 x Ir +/- 20%
Operating Altitude6561.68 ft (2000 m)
Rated Operational Voltage690 V AC
Ambient Air Temperature For Storage-40 to 185°F (-40 to 85°C)
Protective TreatmentTH IEC 60068
Motor Power KW2.2 kW 400 to 440 V AC 50/60 Hz 1 phase
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Immunity To Microbreaks3 ms
Immunity To Voltage Dips70% / 500 ms IEC 61000-4-11
Typical Current Consumption130 mA 24 V DC I maximum while closing with LUB12, 220 mA 24 V DC I maximum while closing with LUB32, 220 mA 24 V DC I maximum while closing with LUB38, 60 mA 24 V DC I rms sealed with LUB12, 80 mA 24 V DC I rms sealed with LUB32, 80 mA 24 V DC I rms sealed with LUB38
Vibration Resistance2 gn 5 to 300 Hz power poles open IEC 60068-2-6, 4 gn 5 to 300 Hz power poles closed IEC 60068-2-6
Fixing ModePlug-in front face)
Immunity To Radioelectric Fields10 V IEC 61000-4-6
Control Circuit Voltage Limits20 to 27 V DC 24 V in operation, 14.5 V DC 24 V drop-out
Device ApplicationMotor control, Motor protection
Rated Impulse Withstand Voltage6 kV IEC 60947-6-2
Thermal Overload ClassClass 10 40 to 60 Hz -13 to 131°F (-25 to 55°C) IEC 60947-6-2, Class 10 40 to 60 Hz -13 to 131°F (-25 to 55°C) UL 508
Product CompatibilityPower base LUB12, Power base LUB32, Power base LUB38, Power base LUB120, Power base LUB320, Power base LUB380, Reversing contactor breaker LU2B12BL, Reversing contactor breaker LU2B32BL, Reversing contactor breaker LU2B38BL
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#Advcntrlunitcl101Ph 312A 24Vdc
#SCHNEIDER ELECTRIC
#Mfr LUCC12BL
#SCHNEIDER ELECTRIC
#GRG0561815
#mfr:LUCC12BL
#part number:LUCC12BL
#pn:LUCC12BL
#part code:LUCC12BL
#item number:LUCC12BL
#product code:LUCC12BL
#manufacturer number:LUCC12BL
#manufacturers part number:LUCC12BL
#mfn:LUCC12BL

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!