Item | Overload Module |
Overload Relay Amp Setting | 3 to 12 A |
Coil Volts | 24V DC |
Number of Poles | 3 |
Standards | CSA C22.2 No 60947-4-1, EN 60947-6-2, IEC 60947-6-2, REACH, RoHS, UL Listed 60947-4-1 |
Depth | 60 mm |
Width | 45 mm |
Height | 66 mm |
Hz | 40 to 60 Hz |
Features | Manual reset, Protection against phase failure and phase imbalance, Protection against overload and short-circuit, Earth fault protection, Free of Halogen, Mercury & Pvc Free, Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock & Vibration |
Frame / Series / Class / Code | Class 10 |
Kit Required for Retrofit Mtg. | No |
Body Height - Relay | 2.6 in |
Overload Relay Current Range | 3 to 12A |
Overall Height - Relay | 2.6 in |
Sensing Method | Thermal |
Body Depth - Relay | 2.36 in |
Reset Type - Relay | Manual |
Trip Class - Overload | 10 |
Body Width - Relay | 1.77 in |
Use With - Contactors and Starters | Mfr. Series LUA1C Contactors |
Item - Relay | IEC Style Overload Relay |
Separate Mounting | No |
Operating Voltage | 690V AC |
Compatible with Manufacturer Model Number | LUB120, LUB320, LUB380 |
Coil Voltage | 24V DC |
Phase | Three |
Reset Type | Manual |
Maximum Operating Temperature | 158 Degrees F |
Maximum Voltage Rating | 690V AC |
Trip Class | 10 |
Compatible with Series | TeSys Ultra |
Maximum Rated Motor Current Adjustment | 12 A |
Minumum Rated Motor Current Adjustment | 3 A |
Minimum Operating Temperature | -13 Degrees F |
Compatibility Code | LUCB |
Fire Resistance | 1760°F (960°C) parts supporting live components IEC 60695-2-12, 1202°F (650°C) IEC 60695-2-12 |
Resistance To Electrostatic Discharge | 8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2 |
Tripping Threshold | 14.2 x Ir +/- 20% |
Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 |
Product Compatibility | Power base LUB12, Power base LUB32, Power base LUB38, Power base LUB120, Power base LUB320, Power base LUB380, Reversing contactor breaker LU2B12BL, Reversing contactor breaker LU2B32BL, Reversing contactor breaker LU2B38BL |
Device Application | Motor control, Motor protection |
Ambient Air Temperature For Operation | -13 to 158°F (-25 to 70°C) |
Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
Protective Treatment | TH IEC 60068 |
Motor Power KW | 5.5 kW 400 to 440 V AC 50/60 Hz, 5.5 kW 500 V AC 50/60 Hz, 9 kW 690 V AC 50/60 Hz |
Reset | Manual reset |
Thermal Overload Class | Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) IEC 60947-6-2, Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) UL 508 |
Immunity To Microbreaks | 3 ms |
Resistance To Radiated Fields | 9.14 V/m (10 V/m) 3 IEC 61000-4-3 |
Utilisation Category | AC-41, AC-43, AC-44 |
Rated Impulse Withstand Voltage | 6 kV IEC 60947-6-2 |
Shock Resistance | 10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27 |
Ambient Air Temperature For Storage | -40 to 185°F (-40 to 85°C) |
Main Function Available | Manual reset, Protection against phase failure and phase imbalance, Protection against overload and short-circuit, Earth fault protection |
Load Type | 3-phase motor self-cooled |
Heat Dissipation | 2 W control circuit with LUB12, 3 W control circuit with LUB32, 3 W control circuit with LUB38 |
Vibration Resistance | 2 gn 5 to 300 Hz power poles open IEC 60068-2-6, 4 gn 5 to 300 Hz power poles closed IEC 60068-2-6 |
Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
Product Specific Application | Basic protection and advanced functions, communication |
Rated Operational Voltage | 690 V AC |
Fixing Mode | Plug-in front face) |
Phase Failure Sensitivity | Yes |
Control Circuit Voltage | 24 V DC |
Typical Current Consumption | 130 mA 24 V DC I maximum while closing with LUB12, 220 mA 24 V DC I maximum while closing with LUB32, 220 mA 24 V DC I maximum while closing with LUB38, 60 mA 24 V DC I rms sealed with LUB12, 80 mA 24 V DC I rms sealed with LUB32, 80 mA 24 V DC I rms sealed with LUB38 |
Rated Insulation Voltage | 690 V IEC 60947-6-2, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1 |
Control Circuit Voltage Limits | 20 to 27 V DC 24 V in operation, 14.5 V DC 24 V drop-out |
Product Or Component Type | Advanced control unit |
Immunity To Voltage Dips | 70% / 500 ms IEC 61000-4-11 |
IP Degree Of Protection | IP20 front panel and wired terminals IEC 60947-1, IP20 other faces IEC 60947-1, IP40 front panel outside connection zone IEC 60947-1 |
Product Certifications | CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine |
Operating Time | 35 ms opening with LUB12 control circuit, 35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit, 70 ms closing with LUB12 control circuit, 70 ms closing with LUB32 control circuit, 70 ms closing with LUB38 control circuit |
Operating Altitude | 6561.68 ft (2000 m) |
Compatible Manufacturer Part Number | LUB120, LUB320, LUB380 |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
Advcntrlunitcl103Ph 312A 24Vdc, 24V DC, 3 Poles, SCHNEIDER ELECTRIC, Mfr# LUCB12BL
$149,99
Free shipping will be applied on orders over $50
Overload Module, Maximum Rated Motor Current Adjustment 12 A, Minumum Rated Motor Current Adjustment 3 A, Coil Voltage 24V DC, Compatible with Series TeSys Ultra, Trip Class 10, Phase Three, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards CSA C22.2 No 60947-4-1, EN 60947-6-2, IEC 60947-6-2, REACH, RoHS, UL Listed 60947-4-1, Compatible with Grainger Part Number 48P499, 48P503, Maximum Operating Temperature 158 Degrees F, Minimum Operating Temperature -13 Degrees F
9999 in stock
Must order in multiples of 1
Subtotal:
$149.99
You must be logged in to post a review.
Reviews
There are no reviews yet.