Advcntrlunitcl103Ph 4518A 24Vdc, 24V DC, 3 Poles, SCHNEIDER ELECTRIC, Mfr# LUCB18BL

$149,99

Free shipping will be applied on orders over $50

Overload Module, Maximum Rated Motor Current Adjustment 18 A, Minumum Rated Motor Current Adjustment 4.5 A, Coil Voltage 24V DC, Compatible with Series TeSys Ultra, Trip Class 10, Phase Three, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards CSA C22.2 No 60947-4-1, EN 60947-6-2, IEC 60947-6-2, REACH, RoHS, UL Listed 60947-4-1, Compatible with Grainger Part Number 48P503, Maximum Operating Temperature 158 Degrees F, Minimum Operating Temperature -13 Degrees F

9999 in stock

Must order in multiples of 1
Subtotal:
$149.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LUCB18BL
Availability: Ships in 5 days
SKU: GRG0561745 Category:
ItemOverload Module
Overload Relay Amp Setting4.5 to 18 A
Coil Volts24V DC
Number of Poles3
Height66 mm
Width45 mm
FeaturesProtection against overload and short-circuit, Manual reset, Earth fault protection, Protection against phase failure and phase imbalance, Free of Halogen, Mercury & Pvc, Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock & Vibration
Depth60 mm
Hz40 to 60 Hz
StandardsCSA C22.2 No 60947-4-1, EN 60947-6-2, IEC 60947-6-2, REACH, RoHS, UL Listed 60947-4-1
Frame / Series / Class / CodeClass 10
Trip Class - Overload10
Overall Height - Relay2.6 in
Body Height - Relay2.6 in
Kit Required for Retrofit Mtg.No
Reset Type - RelayManual
Item - RelayIEC Style Overload Relay
Sensing MethodThermal
Body Width - Relay1.77 in
Use With - Contactors and StartersMfr. Series LUA1C Contactors
Body Depth - Relay2.36 in
Separate MountingNo
Overload Relay Current Range4.5 to 18A
Operating Voltage690V AC
Maximum Operating Temperature158 Degrees F
Compatible with Manufacturer Model NumberLUB320, LUB380
Minimum Operating Temperature-13 Degrees F
Compatible with SeriesTeSys Ultra
PhaseThree
Trip Class10
Maximum Voltage Rating690V AC
Reset TypeManual
Minumum Rated Motor Current Adjustment4.5 A
Maximum Rated Motor Current Adjustment18 A
Coil Voltage24V DC
IP Degree Of ProtectionIP20 front panel and wired terminals IEC 60947-1, IP20 other faces IEC 60947-1, IP40 front panel outside connection zone IEC 60947-1
Immunity To Radioelectric Fields10 V IEC 61000-4-6
Device ApplicationMotor control, Motor protection
Fire Resistance1760°F (960°C) parts supporting live components IEC 60695-2-12, 1202°F (650°C) IEC 60695-2-12
ResetManual reset
Operating Time35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit, 70 ms closing with LUB32 control circuit, 70 ms closing with LUB38 control circuit
Product CompatibilityPower base LUB32, Power base LUB38, Power base LUB320, Power base LUB380, Reversing contactor breaker LU2B32BL, Reversing contactor breaker LU2B38BL
Operating Altitude6561.68 ft (2000 m)
Load Type3-phase motor self-cooled
Vibration Resistance2 gn 5 to 300 Hz power poles open IEC 60068-2-6, 4 gn 5 to 300 Hz power poles closed IEC 60068-2-6
Control Circuit Voltage24 V DC
Product Specific ApplicationBasic protection and advanced functions, communication
Rated Impulse Withstand Voltage6 kV IEC 60947-6-2
Ambient Air Temperature For Storage-40 to 185°F (-40 to 85°C)
Product Or Component TypeAdvanced control unit
Control Circuit Voltage Limits20 to 27 V DC 24 V in operation, 14.5 V DC 24 V drop-out
Shock Resistance10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27
Immunity To Voltage Dips70% / 500 ms IEC 61000-4-11
Resistance To Radiated Fields9.14 V/m (10 V/m) 3 IEC 61000-4-3
Ambient Air Temperature For Operation-13 to 158°F (-25 to 70°C)
Tripping Threshold14.2 x Ir +/- 20%
Protective TreatmentTH IEC 60068
Resistance To Fast Transients2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
Rated Operational Voltage690 V AC
Motor Power KW7.5 kW 400 to 440 V AC 50/60 Hz, 9 kW 500 V AC 50/60 Hz, 15 kW 690 V AC 50/60 Hz
Compatibility CodeLUCB
Rated Insulation Voltage690 V IEC 60947-6-2, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
Main Function AvailableProtection against overload and short-circuit, Manual reset, Earth fault protection, Protection against phase failure and phase imbalance
Phase Failure SensitivityYes
Typical Current Consumption220 mA 24 V DC I maximum while closing with LUB32, 220 mA 24 V DC I maximum while closing with LUB38, 80 mA 24 V DC I rms sealed with LUB32, 80 mA 24 V DC I rms sealed with LUB38
Immunity To Microbreaks3 ms
Utilisation CategoryAC-44, AC-41, AC-43
Product CertificationsCE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
Resistance To Electrostatic Discharge8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Thermal Overload ClassClass 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) IEC 60947-6-2, Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) UL 508
Heat Dissipation3 W control circuit with LUB32, 3 W control circuit with LUB38
Fixing ModePlug-in front face)
Compatible Manufacturer Part NumberLUB320, LUB380
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#Advcntrlunitcl103Ph 4518A 24Vdc
#24V DC
#3 Poles
#SCHNEIDER ELECTRIC
#Mfr LUCB18BL
#SCHNEIDER ELECTRIC
#GRG0561745
#mfr:LUCB18BL
#part number:LUCB18BL
#pn:LUCB18BL
#part code:LUCB18BL
#item number:LUCB18BL
#product code:LUCB18BL
#manufacturer number:LUCB18BL
#manufacturers part number:LUCB18BL
#mfn:LUCB18BL

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!