Item
Blue Series 12 Touchscreen Thermostats
Control Range
45 Degrees to 99 Degrees F
System Switching
Auto-Heat-Cool-Off-Emergency
Dual Transformer Compatible
Yes
Power Method
Hardwired/Battery/Power Stealing
Programs per Week
7, 5-1-1
Features
Has Dehumidification Control, Audible Feedback, Selectable High/Low Temp Limits, Key Pad Programming, Requires 2AA Batteries
Temporary Program Override
Yes
For Use With
Heat Only, Cool Only, Heating and Cooling, Single Stage Gas, Oil, Electric, Multi-Stage Gas, Oil, Electric, Heat Pump, Millivolt, 3-wire Zone Valve
Dehumidification Control
Yes
Temp. Settings per Day
0, 2, 4
Temporary Temperature Hold
Yes
Green Environmental Attribute
Thermostat has Programmable Feature to Reduce Energy Consumption
Terminal Designations
RC, RH, C, W/E, W2, Y, Y2, O/B, G, L, 6, +, S, -, DHM, HM
Fan Switching
Auto-On-Program-Circulate
Remote Sensing Capability
Yes
Humidification Control
Yes
Footnotes
1, 2, 3, 4, 5, 6, 7, 8
Includes
Mounting Hardware
Stages
2H/2C Conventional, 4H/2C Heat Pump
Type
Touch Screen Programmable Multi Stage, H/C or HP
Temperature settings per day
0, 2, 4
Maximum Operating Temperature
105 Degrees F
Differential Cool
0.9 Degrees F, 1.7 Degrees F
Operating Temperature Range
32 Degrees to 105 Degrees F
Filter Change Reminder
Yes
Battery Type
(2) AA Batteries
Compatible System Type
Electric Forced Air Furnaces, Gas Forced Air Furnaces, Heat Pump with Aux, Millivolt
Maximum Control Temperature
99 Degrees F
Minimum Operating Temperature
32 Degrees F
Temperature Scale
Fahrenheit/Celsius
Number of Heating Stages - Heat Pump System
4
Backlit Type
Touch Activated or Continuous with Common Wire
Mounting Direction/Shape
Horizontal
Application/Stages
Heat and Cool; 2H/2C Conventional, 4H/2C Heat Pump
Number of Cooling Stages - Conventional System
2
Smart Connectivity
No Connectivity
Differential Type
Adjustable
Thermostat Type
Low Voltage
Number of Cooling Stages - Heat Pump System
2
Mounting Direction
Horizontal
Programming Capability
5-1-1, 7 Day
Number of Heating Stages - Conventional System
2
Electrical Connection Type
Hardwired
Minimum Operating Humidity
0 %
System/Fan Settings
Auto-Cool-Emergency Heat-Off/Auto-On
Contact Rating
20 to 30V AC
System Settings
Auto-Cool-Emergency Heat-Off
Temperature Differential
0.6 Degrees F, 1.2 Degrees F
Differential Heat
0.5 Degrees F, 1.9 Degrees F
Operating Humidity Range
0% to 90% RH
Minimum Control Temperature
45 Degrees F
Maximum Operating Humidity
90 %
Temperature Control Range
45 Degrees to 99 Degrees F
Country of Origin (subject to change)
Viet Nam