Item
Emergency Cable Pull Switch
Switch Function
Maintained
AC Contact Rating
3 A @ 240 V
Switching Ability
Single Cable
DC Contact Rating
0.27 A @ 250 V
Standards
CCC, CSA, CSA C22.2 No. 14 Machinery Directive 2006/42/EC, EN/IEC 60204-1, EN/IEC 60947-5, EN/IEC 60947-5-5, EN/ISO 13850, UL 508, Work Equipment Directive 2009/104/EC
Cable Connection Location
Left or Right
Min. Current
Not Applicable
For Use With
Preventa XPS Safety Relays
Length (Straight Wireway)
7.76 in
Operating Temperature - Minimum
-13 Degrees F
Cable Span - Maximum
98 ft
Operating Temperature - Maximum
158 Degrees F
Manufacturer Warranty Length
18 mo
NEMA Enclosure Rating
1, 12, 4
Overvoltage Category
class I EN/IEC 61140 || class I NF C 20-030
[Ithe] Conventional Enclosed Thermal Current
10 A
Contact Operation
slow-break
Cover Material
stainless steel
Local Signalling
without pilot light
Tightening Torque
0.8-1.2 N.m
[Ui] Rated Insulation Voltage
500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-1
Terminals Description Iso N°1
(13-14)NO || (21-22)NC
Distance Between Cable Supports
5-5 m
Positive Opening
with EN/IEC 60947-5-1
Ip Degree Of Protection
IP65 IEC 60529
Ambient Air Temperature For Storage
-40-70°C
Maximum Resistance Across Terminals
25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Short-Circuit Protection
10 A cartridge fuse gG EN/IEC 60269
Contacts Type And Composition
1 NC + 1 NO
Vibration Resistance
10 gn 10-150 Hz)EN/IEC 60068-2-6
Mechanical Durability
800000 cycles
Safety Level
can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Trigger Cable Maximum Length
30 m
Housing Colour
red RAL 3000
Product Or Component Type
latching emergency stop rope pull switch
Connections - Terminals
screw clamp terminal, 1 x 0.5 to 2 x 1.5 mm²
Ambient Air Temperature For Operation
-25-70°C
Shock Resistance
50 gn 11 ms EN/IEC 60068-2-27
[Ie] Rated Operational Current
3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Cable Entry Number
3 tapped entry 1/2
Product Certifications
UL category NISD emergency stop devices || CSA || CCC
Trigger Cable Anchor Point
RH or LH side
Country of Origin (subject to change)
Multiple