Item | Contactor Time Delay Auxcontact Block |
Accessory Type | Contactor Time Delay Auxcontact Block |
Height | 48 mm |
Product Or Component Type | time delay auxiliary contact block |
Ambient Air Temperature For Storage | -60-80°C |
Mounting Location | front |
Product Certifications | IECEE CB Scheme || UL || CSA || CCC || EAC || UKCA |
Pole Contact Composition | 1 NO + 1 NC |
Operating Altitude | 9842.52 ft (3000 m) |
Permissible Short-Time Rating | 100 A 60°C 1 s || 120 A 60°C 500 ms || 140 A 60°C 100 ms |
Insulation Resistance | > 10 MOhm |
[Ith] Conventional Free Air Thermal Current | 10 A 60°C |
Auxiliary Contacts Operation | time delay |
Width | 44 mm |
Protection Type | gG fuse 10 A |
Product Name | TeSys Deca |
Timer Type | on delay |
Time Delay Range | 1...30 s |
Standards | CSA C22.2 No 60947-5-1 || GB/T 14048.5 || EN/IEC 60947-5-1 |
Ip Degree Of Protection | IP20 conforming to IEC 60529 |
Environmental Characteristic | normal environment |
Connections - Terminals | screw clamp terminals 1 1-2.5 mm?flexible with cable end || screw clamp terminals 1 1-2.5 mm?flexible without cable end || screw clamp terminals 2 1-2.5 mm?flexible with cable end || screw clamp terminals 2 1-2.5 mm?flexible without cable end || screw clamp terminals 1 1-2.5 mm?rigid || screw clamp terminals 2 1-2.5 mm?rigid || screw clamp terminals |
Tightening Torque | 1.7 N.m flat ? 6 mm || 1.7 N.m Philips No 2 || 1.7 N.m pozidriv No 2 |
Device Application | star delta starter |
[Ie] Rated Operational Current | 6 A120 V AC-15 || 1.04 A690 V AC-15 || 0.55 A125 V DC-13 || 0.1 A600 V DC-13 |
Range Compatibility | TeSys D CAD || TeSys D LC1D || TeSys F LC1F || TeSys F CR1F || TeSys Deca CAD || TeSys Deca LC1D |
[Ui] Rated Insulation Voltage | 690 V IEC 60947-5-1 || 600 V UL 60947-5-1 || 600 V CSA C22.2 No 60947-5-1 |
[Ue] Rated Operational Voltage | 690 V AC 25...400 Hz |
Minimum Switching Voltage | 17 V |
Non-Overlap Time | 1.5 ms on de-energisation no overlap between NC and NO contact || 1.5 ms on energisation no overlap between NC and NO contact |
Irms Rated Making Capacity | 140 A <= 690 V AC IEC 60947-5-1 || 250 A <= 690 V DC IEC 60947-5-1 |
Depth | 61 mm |
Ambient Air Temperature For Operation | -40-70°C |
Color | dark grey |
Range | TeSys || TeSys Deca |
Minimum Switching Current | 5 mA |
Mechanical Durability | 5 Mcycles |
Protective Treatment | TH IEC 60068 |
Rated Operational Current | 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, 0.1 A at 600 V DC-13 |
Rated Operational Voltage | 690 V AC 25 to 400 Hz |
Rated Insulation Voltage | 690 V IEC 60947-5-1, 600 V UL 60947-5-1, 600 V CSA C22.2 No 60947-5-1 |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
Contactor Time Delay Auxcontact Block, SCHNEIDER ELECTRIC, Mfr# LADS2