Electrical Connections
1/2
Valve Design
2-Way/2-Position
Item
Cryogenic Solenoid Valve
Valve Configuration
Normally Closed
Body Material - Valves
Brass
Max. Operating Pressure Differential Water
100 psi
NEMA Rating
1, 2, 3, 3S, 4, 4X
Coefficient of Volume
0.73
Max. Operating Pressure Differential Light Oil
100 psi
Seal Material - Valves
PTFE
Coil Enclosure
Watertight No Junction Box
Valve Ways and Positions
2-Way/2-Position
Standards
CSA Certified, Meets Applicable CE Directives
Max. Operating Pressure Differential
100 psi
Max. Fluid Temp.
150 Degrees F
Environmental Rating - Valves
Corrosive, Hazardous, Indoor, Outdoor
Max. Operating Pressure Differential Air/Inert Gas
100 psi
Min. Operating Pressure Differential
0 psi
Application
Boilers, Burners, Car Wash Equipment, Compressors, Dishwashing and Laundry Equipment, Food Processing, Pumps
Operation Type
Direct Acting
Mounting Orientation
Horizontal or Vertical
Valve Starting Configuration
Normally Closed
Operating Pressure Differential Air/Inert Gas - Minimum
0 psi
NEMA Enclosure Rating
1, 2, 3, 3S, 4, 4X
Environmental Rating
Corrosive, Hazardous, Indoor, Outdoor
Operating Pressure Differential Natural Gas - Maximum
Not Applicable
Valve Positions
2-Position
Operating Pressure Differential Cryogenic Fluid - Maximum
100 psi
Operating Pressure Differential Fuel Oil - Minimum
Not Applicable
Operating Pressure Differential - Minimum
0 psi
Operating Pressure Differential Fuel Gas - Maximum
Not Applicable
Operating Pressure Differential Steam - Minimum
Not Applicable
Operating Pressure Differential - Maximum
100 psi
Operating Pressure Differential Fuel Gas - Minimum
Not Applicable
Operating Pressure Differential Natural Gas - Minimum
Not Applicable
Outlet Connection Type
NPTF
Operating Pressure Differential Air/Inert Gas - Maximum
100 psi
Operating Pressure Differential Light Oil - Maximum
100 psi
Operating Pressure Differential Fuel Oil - Maximum
Not Applicable
Operating Pressure Differential Hot Water - Maximum
Not Rated
Operating Pressure Differential Steam - Maximum
Not Rated
Operating Pressure Differential Light Oil - Minimum
0 psi
Fluid Temperature - Maximum
150 Degrees F
Coefficient of Volume (Cv)
0.73
Operating Pressure Differential Cryogenic Fluid - Minimum
0 psi
Ambient Temperature - Minimum
-13 Degrees F
Operating Pressure Differential Water - Maximum
100 psi
Operating Pressure Differential Hot Water - Minimum
Not Applicable
For Media
Aggressive Gases, Aggressive Liquids, Air, Ammonia, Biodiesel Fuel, Cryogenic Fluids, Fuel Oil, Hot Water, Inert Gases, Light Oil, Liquid Propane Gas, Natural Gas, Oxygen, Steam, Water
Inlet Connection Type
NPTF
Operating Pressure Differential Water - Minimum
0 psi
Country of Origin (subject to change)
Mexico