Item | Definite Purpose Magnetic Contactor |
Full Load Amps-Inductive | 30 A |
Action | Non-Reversing |
Full Load Amps-Resistive | 40 A |
Number of Poles | 2 |
Coil Volts | 120V AC |
Reversing | No |
HP @ 1 Phase - 230V | 3 |
HP @ 1 Phase - 120V | 2 hp |
HP @ 1 Phase - 240V | 3 hp |
Height | 2.64 in |
Width | 2.17 in |
Depth | 3.41 in |
Enclosure NEMA Rating | No Enclosure |
Standards | CE, cRUus |
Enclosure Type | Open |
Hz | 50/60 |
Series | Compact |
Includes | Not Applicable |
Phase | Single |
Reversing Capability | Non-Reversing |
Mounting Postion | Horizontal, Vertical |
Number of Normally Open Main Contacts | 2 |
Minimum Operating Temperature | -40 Degrees F |
Horsepower @ Three Phase - 208V AC | Not Rated |
IP Rating | Not Applicable |
Terminal Connection Type | Screw Terminals |
Frequency | 50/60 Hz |
Overall Depth | 3.19 in |
Number of Terminals | 6 |
Full Load Current - Resistive | 40 A |
Horsepower @ Three Phase - 240V AC | Not Rated |
NEMA Enclosure Material | Not Applicable |
Horsepower @ Single Phase - 120V AC | 2 hp |
Number of Normally Closed Main Contacts | 0 |
Contact Material | Silver Cadmium Oxide |
Response Time | 20 msec |
Maximum Operating Temperature | 158 Degrees F |
Auxiliary Contact Module Capacity | Not Applicable |
Coil Voltage | 120V AC |
Full Load Current - Inductive | 30 A |
Mounting Hole Distance - Height | 1.63 in |
Status Indicator | Mechanical Flag |
Horsepower @ Three Phase - 480V AC | Not Rated |
Horsepower @ Single Phase - 240V AC | 3 hp |
Electrical Operating Durability | 200,000 |
Fluorescent Lighting Current Rating | Not Applicable |
NEMA Enclosure Rating | No Enclosure |
Tungsten Lighting Current Rating | Not Applicable |
Locked Rotor Load | 120 A @ 600V AC, 150 A @ 480V AC, 180 A @ 240/277V AC |
Overall Height | 2.32 in |
Frame Size | Not Applicable |
Includes Shunt | Not Applicable |
Mounting Style | Through Panel |
Mounting Hole Distance - Width | 1.61 in |
Maximum Voltage Rating | 600V AC |
Resistance Properties | Not Applicable |
Input Control Type | Not Applicable |
Overall Width | 1.97 in |
Horsepower @ Three Phase - 600V AC | Not Rated |
LED Lighting Current Rating | Not Applicable |
Contactor Style | HVACR Definite Purpose Contactor |
Mechanical Operating Durability | 500,000 |
Mounting Hole Diameter | Not Applicable |
Country of Origin (subject to change) | China |
Package Quantity | 1 |
120VAC Non-Reversing Definite Purpose Contactor 2P 30A, DAYTON, Mfr# 6GNY6
$26.47
Free shipping will be applied on orders over $50
Definite Purpose Magnetic Contactor, LED Lighting Current Rating Not Applicable, Coil Voltage 120V AC, Number of Poles 2, NEMA Enclosure Rating No Enclosure, Tungsten Lighting Current Rating Not Applicable, Fluorescent Lighting Current Rating Not Applicable, Reversing Capability Non-Reversing, Frame Size Not Applicable, Horsepower @ Single Phase - 240V AC 3 hp, Horsepower @ Single Phase - 120V AC 2 hp, Full Load Current - Resistive 40 A, Full Load Current - Inductive 30 A
9999 in stock
Must order in multiples of 1
Subtotal:
$26.47
You must be logged in to post a review.
Reviews
There are no reviews yet.