| Property | Value |
|---|---|
| Item | Electronic Pressure Sensor |
| Range | -14.6 to 145 psi |
| Analog Output | 4 to 20mA or 0 to 10V DC |
| Control Output | PNP |
| On/Off Setting | Programmable |
| Max. Pressure | 2,175 psi |
| Power Required | 18 to 30V DC |
| Process Connection | 1/4 in NPT |
| Electrical Connection | M12 |
| Display | 4 Digit LED |
| Operating Temp. Range | -13 Degrees to 176 Degrees F |
| IP Rating | IP65, IP67 |
| Housing Material | PBT, Stainless Steel |
| Standards | CE, CRN, cULus, DIN EN 60068-2-27, DIN EN 60068-2-6, DIN EN 61000-6-2, DIN EN 61000-6-3, DNV.COM/AF, IEC 61131-9, IO-Link, UKCA |
| Wetted Materials | Ceramic, FKM, Stainless Steel |
| Overall Height | 3.57 in |
| Application | for industrial applications |
| Overall Width | 1.34 in |
| Hysteresis deviation [% of the span] | u003cΓΒ± 0,1; (Turn down 1:1) |
| Pressure rating | 75 bar 1087 psi 7.5 Mpa |
| IO-Link revision | 1.1 |
| Permanent current rating of switching output DC [mA] | 250 |
| MTTF [years] | 138 |
| Repeatability [% of the span] | u003cΓΒ± 0,1; (with temperature fluctuations u003c 10 K; Turn down 1:1) |
| Measuring range | -1...10 bar -14.6...145 psi -100...1000 kPa -0.1...1 MPa |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Number of analogue outputs | 1 |
| Analogue end point | 1...10 bar 14.6...145 psi 0.1...1 MPa |
| Min. insulation resistance [MΞ©] | 100; (500 V DC) |
| IO-Link process data (cyclical) | function bit length pressure 16 device status 4 binary switching information 2, function bit length pressure 14 binary switching information 2 |
| Damping for the analogue output dAA [s] | 0...4 |
| Transmission type | COM2 (38,4 kBaud) |
| Output signal | switching signal; analogue signal; IO-Link; (configurable) |
| Protection | IP 65; IP 67 |
| In steps of | 0.01 bar 0.1 psi 0.001 MPa, 0.02 bar 0.2 psi 0.002 MPa |
| Max. response time analogue output [ms] | 3 |
| Max. voltage drop switching output DC [V] | 2 |
| Materials (wetted parts) | stainless steel (1.4404 / 316L); AI2O3 (96%; ceramics); FKM |
| Shock resistance | DIN EN 60068-2-27 50 g (11 ms) |
| Reverse polarity protection | yes |
| EMC | DIN EN 61000-6-2 DIN EN 61000-6-3 |
| Analogue current output [mA] | 4...20; (scalable 1:5) |
| SIO mode | yes |
| Required master port type | A; (when pin 2 not connected: B) |
| Ambient temperature [Β°C] | -25...80 |
| IO-Link resolution pressure [bar] | 0.005, 0.01 |
| Total number of outputs | 2 |
| Analogue voltage output [V] | 0...10; (scalable 1:5) |
| UL approval | UL Approval no. J012 |
| Media | liquids and gases |
| Overload protection | yes |
| Vibration resistance | DIN EN 60068-2-6 20 g (10...2000 Hz) |
| Min. process cycle time [ms] | 2.3, 3 |
| Min. bursting pressure | 150 bar 2175 psi 15 MPa |
| Parameter setting options | hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output |
| Type of short-circuit protection | pulsed |
| Protection class | III |
| Long-term stability [% of the span] | u003cΓΒ± 0,05; (Turn down 1:1; per 6 months) |
| Integrated watchdog | yes |
| Min. load resistance [Ξ©] | 2000 |
| Measuring element | ceramic-capacitive pressure measuring cell |
| Min. pressure cycles | 100 million |
| Current consumption [mA] | u003c 35 |
| Special feature | Gold-plated contacts |
| Electrical design | PNP/NPN |
| Response time [ms] | u003c 1.5 |
| Switching frequency DC [Hz] | u003c 500 |
| Restrictor element integrated | no (can be retrofitted) |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Set point SP | -0.94...10 bar -13.6...145 psi -0.094...1 MPa |
| Materials | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
| Temperature coefficient zero point [% of the span / 10 K] | u003cΓΒ± 0,2; (-0...80ΓΒ°C) |
| Damping process value dAP [s] | 0...4 |
| SDCI standard | IEC 61131-9 |
| IO-Link functions (acyclical) | application specific tag |
| Output function | normally open / normally closed; (parameterisable) |
| Characteristics deviation [% of the span] | u003cΓΒ± 0,25 (BFSL) / u003cΓΒ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) |
| Short-circuit protection | yes |
| Temperature coefficient span [% of the span / 10 K] | u003cΓΒ± 0,2; (-0...80ΓΒ°C) |
| Min. difference between SP and rP | 0.06 bar 0.6 psi 0.005 MPa, 0.06 bar 0.6 psi 0.006 MPa |
| Vacuum resistance [mbar] | -1000 |
| Delay time programmable dS, dr [s] | 0...50 |
| Max. load [Ξ©] | 500 |
| Storage temperature [Β°C] | -40...100 |
| Analogue start point | -1...8 bar -14.6...116 psi -0.1...0.8 MPa |
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
| Switch point accuracy [% of the span] | u003cΓΒ± 0,4; (Turn down 1:1) |
| Operating voltage [V] | 18...30 DC; (to SELV/PELV) |
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis, Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
| Power-on delay time [s] | 0.3 |
| Reset point rP | -0.98...9.96 bar -14.2...144.4 psi -0.098...0.996 MPa |
| Medium temperature [Β°C] | -25...80 |
| Tightening torque [Nm] | u003e 50; (depends on lubrication, seal and pressure rating) |
| Communication interface | IO-Link |
| MAWP (for applications according to CRN) | 50 bar 725 psi 5 MPa |
| Number of digital outputs | 2 |
| Type of pressure | relative pressure; vacuum |
| Max. load [ΓΒ©] | 500 |
| Ambient temperature [ΓΒ°C] | -25...80 |
| Min. load resistance [ΓΒ©] | 2000 |
| Medium temperature [ΓΒ°C] | -25...80 |
| Min. insulation resistance [MΓΒ©] | 100; (500 V DC) |
| Storage temperature [ΓΒ°C] | -40...100 |
| Compatible Media | Gas, Liquid |
| Pressure - Maximum | 145 psi |
| Proof Pressure | 2,175 psi |
| Operating Temperature - Maximum | 176 Degrees F |
| Pressure - Minimum | -14.6 psi |
| Analog Output Current - Maximum | 20 mA |
| Pressure Connection Type | 1/4 |
| Analog Output Voltage - Minimum | 0 V DC |
| Series | PN |
| Analog Output Voltage - Maximum | 10 V DC |
| Overall Depth | 1.94 in |
| Operating Temperature - Minimum | -13 Degrees F |
| Manufacturer Warranty Length | 5 yr |
| Electrical Design Output | PNP/NPN |
| Analog Output Current - Minimum | 4 mA |
| Voltage Rating - Maximum | 30 V DC |
| Country of Origin (subject to change) | Germany |
| Package Quantity | 1 |
Electronic Pressure Sensor, 2175 psi, Ifm, Mfr#: PN2294
$468.99
Free shipping will be applied on orders over $50
Electronic Pressure Sensor, Range -14.6 to 145 psi, Analog Output 4 to 20mA or 0 to 10V DC, Control Output PNP, Programmable On/Off Setting, Power Required 18 to 30V DC, Process Connection 1/4 in NPT, Electrical Connection M12, Display 4 Digit LED, Wetted Materials Ceramic, FKM, Stainless Steel, Housing Material PBT, Stainless Steel, Operating Temp. Range -13 Degrees to 176 Degrees F, IP Rating IP65, IP67, Max. Pressure 2,175 psi
9999 in stock
Subtotal:
$468.99
You must be logged in to post a review.
Reviews
There are no reviews yet.