Easy TeSys, 3 Poles, 24 V AC, 32 A, Reversing: No, SCHNEIDER, Mfr# DPE32B7

$61,75

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 32 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Easy, Number of Auxillary Contacts 1, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 7 1/2 hp

9999 in stock

Must order in multiples of 1
Subtotal:
$61.75
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER
Mfr #: DPE32B7
Availability: Ships in 5 days
SKU: GRG203481092 Category:

Analogues

ItemIEC Magnetic Contactor
Full Load Amps-Inductive32 A
Full Load Amps-Resistive32 A
Number of Poles3
Coil Volts24 V AC
ReversingNo
HP @ 1 Phase - 120V2 hp
HP @ 1 Phase - 240V3 hp
HP @ 3 Phase - 208V7 1/2 hp
HP @ 3 Phase - 240V7 1/2 hp
HP @ 3 Phase - 480V15 hp
HP @ 3 Phase - 575V20 hp
Aux. Contact Configuration1NO
Enclosure NEMA Rating3R, 4
Hz50/60 Hz
StandardsCSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL Listed, UL 60947-4-1
Depth3.62 in
Width1.77 in
Height3.35 in
Frame / Series / Class / CodeTeSys
Special FeaturesOvervoltage Category III, Minimum Switching Voltage 17 V Signalling Circuit, Insulation Resistance 10 MOhm Signalling Circuit
ApplicationMotor Control, Resistive Load
Overall Height3.35 in
IncludesNot Applicable
Overall Width1.77 in
FeaturesWithout Built-In Suppressor Module
IP RatingIP20
Overvoltage CategoryCAT III
Electrical ConnectionScrew Clamp Terminals
SeriesTeSys Easy
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Thermal Amperage10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit)
Tightening Torque1.7 Nm
Shock Resistance15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Mechanical Durability10 Mcycles
Fuse Amps10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit)
Rated Voltage690V AC, 300V DC
Inrush VA70 VA
Impedance2 mOhm
Electrical Durability1 Mcycles (32 A, AC-3, Less than 440 V), 0.6 Mcycles (40 A, AC-1, Less than 440 V)
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Switching Voltage17 V (Signalling Circuit)
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Non-Overlap Time1.5 ms
Mounts OnPlate, Rail
Impulse Withstand Voltage6 kV
Switching Current5 mA (Signalling Circuit)
Max. Operating Watts7.5 kW (at 220 to 230V AC 50/60 Hz), 15 kW (at 380 to 400V AC 50/60 Hz), 15 kW (at 415V AC 50/60 Hz), 15 kW (at 440V AC 50/60 Hz), 18.5 kW (at 500V AC 50/60 Hz), 18.5 kW (at 660 to 690V AC 50/60 Hz)
Max. Temperature850°C
Rated Insulation Volts600/690V
Signalling Circuit Frequency25 to 400 Hz
Operating Time12 to 22 ms (Closing), 4 to 19 ms (Opening)
Net Weight0.37 kg
Rated Breaking Capacity450 A @ 440V
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit)
Working HeightUp to 6561.68 ft
Control Circuit Voltage LimitsDrop-Out: 0.3 to 0.6 Uc (at 70°C 50/60 Hz), Operational: 0.8 to 1.1 Uc (at 60°C 50 Hz 0.85 to 1.1 Uc (at 60°C 60 Hz), 1 to 1.1 Uc (at 70°C 50/60 Hz)
Operating Speed3600 cycles per hr
Watts Loss2 to 3W
Hold VA7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Overall Depth3.62 in
Frequency50/60 Hz
Reversing CapabilityNon-Reversing
Full Load Current - Inductive32 A
Embedded Surge SuppressorNo
Includes Auxiliary ContactsYes
Number of Normally Open Main Contacts3
Electrical Operating Durability1,000,000, 600,000
Contactor StyleIEC
Mechanical Operating Durability10,000,000
Resistance PropertiesFire Resistant, Insulation Resistant
Minimum Operating Temperature-40 Degrees F
Horsepower @ Single Phase - 240V AC3 hp
Maximum Voltage Rating690V AC
NEMA SizeNot Applicable
Number of Auxillary Contacts1
Horsepower @ Three Phase - 208V AC7 1/2 hp
Coil Voltage24V AC
Mounting StyleDIN Rail, Plate
Horsepower @ Three Phase - 240V AC7 1/2 hp
Horsepower @ Three Phase - 480V AC15 hp
Terminal Connection TypeScrew Clamp Terminals
Maximum Operating Temperature140 Degrees F
NEMA Enclosure RatingNo Enclosure
Horsepower @ Three Phase - 600V AC20 hp
Horsepower @ Single Phase - 120V AC2 hp
Auxiliary Contact Form1NO
Motor Power KW7.5 kW 220 to 230 V AC 50/60 Hz, 15 kW 380 to 400 V AC 50/60 Hz, 15 kW 415 V AC 50/60 Hz, 15 kW 440 V AC 50/60 Hz, 18.5 kW 500 V AC 50/60 Hz, 18.5 kW 660 to 690 V AC 50/60 Hz
Ambient Air Temperature For Operation-40 to 140°F (-40 to 60°C)
Ambient Air Temperature For Storage-76 to 176°F (-60 to 80°C)
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 40 A (at 140°F (60°C)) for power circuit
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 40 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Mounting SupportRail, Plate
Rated Operational Current32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit
Product NameEasy TeSys DPE
Operating Altitude0 to 6561.68 ft (0 to 2000 m)
IP Degree Of ProtectionIP20 front face IEC 60529
Insulation ResistanceGreater than 10 MOhm for signalling circuit
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947
Auxiliary Contact Composition1 NO
Control Circuit Voltage24 V AC 50/60 Hz
Product Or Component TypeContactor
Maximum Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Fire Resistance1562°F (850°C) IEC 60695-2-1
Power Dissipation Per Pole3.2 W AC-1, 1.25 W AC-3
Poles Description3P
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Product CertificationsUL, CSA
Connections - TerminalsControl circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1.5 to 10 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: solid without cable end
Rated Insulation VoltagePower circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Pollution Degree3
Maximum Horse Power Rating2 hp at 115 V AC 50/60 Hz for 1 phase motors, 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Utilisation CategoryAC-4, AC-1, AC-3
Minimum Switching Current5 mA for signalling circuit
Rated Impulse Withstand Voltage6 kV IEC 60947
Pole Contact Composition3 NO
Minimum Switching Voltage17 V for signalling circuit
Contactor ApplicationResistive load, Motor control
Heat Dissipation2 to 3 W 50/60 Hz
Control Circuit TypeAC 50/60 Hz
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor open 10 Gn for 11 ms), Shocks contactor closed 15 Gn for 11 ms)
Auxiliary Contacts TypeMechanically linked 1 NO IEC 60947-5-1
Average Impedance2 mOhm - Ith 40 A 50 Hz for power circuit
Hold-In Power Consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Inrush Power in VA70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Country of Origin (subject to change)Indonesia
Package Quantity1
TAGS:
#Easy TeSys
#3 Poles
#24 V AC
#32 A
#Reversing: No
#SCHNEIDER
#Mfr DPE32B7
#SCHNEIDER
#GRG203481092
#mfr:DPE32B7
#part number:DPE32B7
#pn:DPE32B7
#part code:DPE32B7
#item number:DPE32B7
#product code:DPE32B7
#manufacturer number:DPE32B7
#manufacturers part number:DPE32B7
#mfn:DPE32B7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!