Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 32 A |
Full Load Amps-Resistive | 32 A |
Number of Poles | 3 |
Coil Volts | 24 V AC |
Reversing | No |
HP @ 1 Phase - 120V | 2 hp |
HP @ 1 Phase - 240V | 3 hp |
HP @ 3 Phase - 208V | 7 1/2 hp |
HP @ 3 Phase - 240V | 7 1/2 hp |
HP @ 3 Phase - 480V | 15 hp |
HP @ 3 Phase - 575V | 20 hp |
Aux. Contact Configuration | 1NO |
Enclosure NEMA Rating | 3R, 4 |
Hz | 50/60 Hz |
Standards | CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL Listed, UL 60947-4-1 |
Depth | 3.62 in |
Width | 1.77 in |
Height | 3.35 in |
Frame / Series / Class / Code | TeSys |
Special Features | Overvoltage Category III, Minimum Switching Voltage 17 V Signalling Circuit, Insulation Resistance 10 MOhm Signalling Circuit |
Application | Motor Control, Resistive Load |
Overall Height | 3.35 in |
Includes | Not Applicable |
Overall Width | 1.77 in |
Features | Without Built-In Suppressor Module |
IP Rating | IP20 |
Overvoltage Category | CAT III |
Electrical Connection | Screw Clamp Terminals |
Series | TeSys Easy |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit) |
Tightening Torque | 1.7 Nm |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Mechanical Durability | 10 Mcycles |
Fuse Amps | 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit) |
Rated Voltage | 690V AC, 300V DC |
Inrush VA | 70 VA |
Impedance | 2 mOhm |
Electrical Durability | 1 Mcycles (32 A, AC-3, Less than 440 V), 0.6 Mcycles (40 A, AC-1, Less than 440 V) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Switching Voltage | 17 V (Signalling Circuit) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Non-Overlap Time | 1.5 ms |
Mounts On | Plate, Rail |
Impulse Withstand Voltage | 6 kV |
Switching Current | 5 mA (Signalling Circuit) |
Max. Operating Watts | 7.5 kW (at 220 to 230V AC 50/60 Hz), 15 kW (at 380 to 400V AC 50/60 Hz), 15 kW (at 415V AC 50/60 Hz), 15 kW (at 440V AC 50/60 Hz), 18.5 kW (at 500V AC 50/60 Hz), 18.5 kW (at 660 to 690V AC 50/60 Hz) |
Max. Temperature | 850°C |
Rated Insulation Volts | 600/690V |
Signalling Circuit Frequency | 25 to 400 Hz |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Net Weight | 0.37 kg |
Rated Breaking Capacity | 450 A @ 440V |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit) |
Working Height | Up to 6561.68 ft |
Control Circuit Voltage Limits | Drop-Out: 0.3 to 0.6 Uc (at 70°C 50/60 Hz), Operational: 0.8 to 1.1 Uc (at 60°C 50 Hz 0.85 to 1.1 Uc (at 60°C 60 Hz), 1 to 1.1 Uc (at 70°C 50/60 Hz) |
Operating Speed | 3600 cycles per hr |
Watts Loss | 2 to 3W |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Overall Depth | 3.62 in |
Frequency | 50/60 Hz |
Reversing Capability | Non-Reversing |
Full Load Current - Inductive | 32 A |
Embedded Surge Suppressor | No |
Includes Auxiliary Contacts | Yes |
Number of Normally Open Main Contacts | 3 |
Electrical Operating Durability | 1,000,000, 600,000 |
Contactor Style | IEC |
Mechanical Operating Durability | 10,000,000 |
Resistance Properties | Fire Resistant, Insulation Resistant |
Minimum Operating Temperature | -40 Degrees F |
Horsepower @ Single Phase - 240V AC | 3 hp |
Maximum Voltage Rating | 690V AC |
NEMA Size | Not Applicable |
Number of Auxillary Contacts | 1 |
Horsepower @ Three Phase - 208V AC | 7 1/2 hp |
Coil Voltage | 24V AC |
Mounting Style | DIN Rail, Plate |
Horsepower @ Three Phase - 240V AC | 7 1/2 hp |
Horsepower @ Three Phase - 480V AC | 15 hp |
Terminal Connection Type | Screw Clamp Terminals |
Maximum Operating Temperature | 140 Degrees F |
NEMA Enclosure Rating | No Enclosure |
Horsepower @ Three Phase - 600V AC | 20 hp |
Horsepower @ Single Phase - 120V AC | 2 hp |
Auxiliary Contact Form | 1NO |
Motor Power KW | 7.5 kW 220 to 230 V AC 50/60 Hz, 15 kW 380 to 400 V AC 50/60 Hz, 15 kW 415 V AC 50/60 Hz, 15 kW 440 V AC 50/60 Hz, 18.5 kW 500 V AC 50/60 Hz, 18.5 kW 660 to 690 V AC 50/60 Hz |
Ambient Air Temperature For Operation | -40 to 140°F (-40 to 60°C) |
Ambient Air Temperature For Storage | -76 to 176°F (-60 to 80°C) |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit, 40 A (at 140°F (60°C)) for power circuit |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 40 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Mounting Support | Rail, Plate |
Rated Operational Current | 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit |
Product Name | Easy TeSys DPE |
Operating Altitude | 0 to 6561.68 ft (0 to 2000 m) |
IP Degree Of Protection | IP20 front face IEC 60529 |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
IRMS Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947 |
Auxiliary Contact Composition | 1 NO |
Control Circuit Voltage | 24 V AC 50/60 Hz |
Product Or Component Type | Contactor |
Maximum Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Power Dissipation Per Pole | 3.2 W AC-1, 1.25 W AC-3 |
Poles Description | 3P |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Product Certifications | UL, CSA |
Connections - Terminals | Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1.5 to 10 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: solid without cable end |
Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL |
Pollution Degree | 3 |
Maximum Horse Power Rating | 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
Utilisation Category | AC-4, AC-1, AC-3 |
Minimum Switching Current | 5 mA for signalling circuit |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Pole Contact Composition | 3 NO |
Minimum Switching Voltage | 17 V for signalling circuit |
Contactor Application | Resistive load, Motor control |
Heat Dissipation | 2 to 3 W 50/60 Hz |
Control Circuit Type | AC 50/60 Hz |
Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor open 10 Gn for 11 ms), Shocks contactor closed 15 Gn for 11 ms) |
Auxiliary Contacts Type | Mechanically linked 1 NO IEC 60947-5-1 |
Average Impedance | 2 mOhm - Ith 40 A 50 Hz for power circuit |
Hold-In Power Consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C)) |
Inrush Power in VA | 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
Country of Origin (subject to change) | Indonesia |
Package Quantity | 1 |
Easy TeSys, 3 Poles, 24 V AC, 32 A, Reversing: No, SCHNEIDER, Mfr# DPE32B7
$61,75
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 32 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Easy, Number of Auxillary Contacts 1, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 7 1/2 hp
9999 in stock
Must order in multiples of 1
Subtotal:
$61.75
You must be logged in to post a review.