Item | Electronic Pressure Sensor |
Range | 0 to 5800 psi |
Analog Output | 4 to 20mA or 0 to 10V DC |
Control Output | PNP |
On/Off Setting | Programmable |
Max. Pressure | 24,650 psi |
Power Required | 18 to 30V DC |
Process Connection | 1/4 in NPT |
Electrical Connection | 4 Pin M12 |
Display | 4 Digit LED |
Operating Temp. Range | -13 Degrees to 176 Degrees F |
IP Rating | 65/67 |
Standards | CE, CULus |
Housing Material | Stainless Steel |
Wetted Materials | Stainless Steel |
Application | for industrial applications |
Characteristics deviation [% of the span] | <± 0,25 (BFSL) / <± 0,5 (LS), (Turn down 1:1, BFSL = Best Fit Straight Line, LS = limit value setting) |
MTTF [years] | 129 |
Max. voltage drop switching output DC [V] | 2 |
Short-circuit protection | yes |
IO-Link functions (acyclical) | application specific tag |
Number of inputs and outputs | Number of digital outputs: 2, Number of analogue outputs: 1 |
Overload protection | yes |
Analogue end point | 80...400 bar 1160...5800 psi 8...40 MPa |
Output signal | switching signal, analogue signal, IO-Link, (configurable) |
Temperature coefficient zero point [% of the span / 10 K] | 0,2, (-25...80°C) |
Min. pressure cycles | 100 million |
Min. bursting pressure | 1700 bar 24650 psi 170 MPa |
Delay time programmable dS, dr [s] | 0...50 |
Number of analogue outputs | 1 |
Max. load [?] | 500 |
Total number of outputs | 2 |
Set point SP | 2.5...400 bar 37...5802 psi 0.25...40 MPa, 2.5...400 bar 40...5800 psi 0.25...40 MPa |
MAWP (for applications according to CRN) | 800 bar 11580 psi 80 MPa |
Min. difference between SP and rP | 1.7 bar 24 psi 0.17 MPa, 2 bar 30 psi 0.2 MPa |
Response time [ms] | < 1.5 |
Integrated watchdog | yes |
SIO mode | yes |
Current consumption [mA] | < 35 |
Long-term stability [% of the span] | <± 0,05, (Turn down 1:1, per 6 months) |
Number of digital outputs | 2 |
UL approval | UL Approval no. J014 |
Max. response time analogue output [ms] | 3 |
Tightening torque [Nm] | > 50, (depends on lubrication, seal and pressure rating) |
Transmission type | COM2 (38,4 kBaud) |
Restrictor element integrated | no (can be retrofitted) |
Reset point rP | 1...398.5 bar 10...5780 psi 0.1...39.85 MPa, 0.9...398.4 bar 13...5778 psi 0.09...39.84 MPa |
Communication interface | IO-Link |
Connection | Connector: 1 x M12, coding: A, Contacts: gold-plated |
Repeatability [% of the span] | <± 0,1, (with temperature fluctuations < 10 K, Turn down 1:1) |
Power-on delay time [s] | 0.3 |
Damping process value dAP [s] | 0...4 |
Shock resistance | DIN EN 60068-2-27 50 g (11 ms) |
Measuring element | metallic thin film cell |
Pressure rating | 800 bar 11580 psi 80 Mpa |
Electrical design | PNP/NPN |
Min. load resistance [?] | 2000 |
Materials | 1.4542 (17-4 PH / 630), stainless steel (1.4404 / 316L), PBT+PC-GF30, PBT-GF20, PC |
Protection | IP 65, IP 67 |
Storage temperature [°C] | -40...100 |
Min. process cycle time [ms] | 3, 2.3 |
Media | liquids and gases |
Reverse polarity protection | yes |
In steps of | 0.1 bar 1 psi 0.01 MPa, 0.5 bar 10 psi 0.05 MPa |
IO-Link resolution pressure [bar] | 0.1, 0.2 |
EMC | DIN EN 61000-6-2 DIN EN 61000-6-3 |
Analogue start point | 0...320 bar 0...4640 psi 0...32 MPa |
Permanent current rating of switching output DC [mA] | 250 |
Min. insulation resistance [M?] | 100, (500 V DC) |
Temperature coefficient span [% of the span / 10 K] | 0,2, (-25...80°C) |
Special feature | Gold-plated contacts |
Output function | normally open / normally closed, (parameterisable) |
Hysteresis deviation [% of the span] | <± 0,1, (Turn down 1:1) |
IO-Link process data (cyclical) | function bit length pressure 16 device status 4 binary switching information 2, function bit length pressure 14 binary switching information 2 |
IO-Link revision | 1.1 |
Measuring range | 0...400 bar 0...5800 psi 0...40 MPa |
Type of pressure | relative pressure |
Switch point accuracy [% of the span] | <± 0,4, (Turn down 1:1) |
Analogue current output [mA] | 4...20, (scalable 1:5) |
Switching frequency DC [Hz] | < 500 |
Operating voltage [V] | 18...30 DC, (to SELV/PELV) |
Profiles | Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000), Smart Sensor: Process Data Variable, Device Identification, Device Diagnosis |
Required master port type | A, (when pin 2 not connected: B) |
Ambient temperature [°C] | -25...80 |
Analogue voltage output [V] | 0...10, (scalable 1:5) |
Vibration resistance | DIN EN 60068-2-6 20 g (10...2000 Hz) |
Medium temperature [°C] | -25...80 |
Type of short-circuit protection | pulsed |
Damping for the analogue output dAA [s] | 0...4 |
Vacuum resistance [mbar] | -1000 |
Pressure Equipment Directive | Sound engineering practice, can be used for group 2 fluids, group 1 fluids on request |
Protection class | III |
SDCI standard | IEC 61131-9 |
Parameter setting options | hysteresis / window, normally open / normally closed, switch-on/switch-off delay, Damping, Display unit, current/voltage output |
Materials (wetted parts) | 1.4542 (17-4 PH / 630) |
Country of Origin (subject to change) | Germany |
Package Quantity | 1 |
Electronic Pressure Sensor, 24,650 psi, IFM, Mfr# PN2270
$445,99
Free shipping will be applied on orders over $50
Electronic Pressure Sensor, Range 0 to 5800 psi, Analog Output 4 to 20mA or 0 to 10V DC, Control Output PNP, Programmable On/Off Setting, Power Required 18 to 30V DC, Process Connection 1/4 in NPT, Electrical Connection 4 Pin M12, Display 4 Digit LED, Wetted Materials Stainless Steel, Housing Material Stainless Steel, Operating Temp. Range -13 Degrees to 176 Degrees F, IP Rating 65/67, Max. Pressure 24,650 psi, Standards CE, CULus