Item | Electronic Pressure Sensor |
Range | -1.8 to 36.3 psi |
Analog Output | 4 to 20mA or 0 to 10V DC |
Control Output | PNP |
On/Off Setting | Programmable |
Max. Pressure | 725 psi |
Power Required | 18 to 30V DC |
Process Connection | 1/4 in NPT |
Electrical Connection | 4 Pin M12 |
Display | 4 Digit LED |
Operating Temp. Range | -13 Degrees to 176 Degrees F |
IP Rating | 65/67 |
Standards | CE, CULus |
Housing Material | Stainless Steel |
Wetted Materials | Stainless Steel |
Application | for industrial applications |
Output signal | switching signal, analogue signal, IO-Link, (configurable) |
Communication interface | IO-Link |
Max. voltage drop switching output DC [V] | 2 |
Number of inputs and outputs | Number of digital outputs: 2, Number of analogue outputs: 1 |
Switch point accuracy [% of the span] | <± 0,4, (Turn down 1:1) |
Vibration resistance | DIN EN 60068-2-6 20 g (10...2000 Hz) |
Operating voltage [V] | 18...30 DC, (to SELV/PELV) |
Media | liquids and gases |
Temperature coefficient span [% of the span / 10 K] | <± 0,2, (-0...80°C) |
IO-Link resolution pressure [bar] | 0.001 |
Permanent current rating of switching output DC [mA] | 250 |
Measuring element | ceramic-capacitive pressure measuring cell |
IO-Link functions (acyclical) | application specific tag |
Connection | Connector: 1 x M12, coding: A, Contacts: gold-plated |
Pressure Equipment Directive | Sound engineering practice, can be used for group 2 fluids, group 1 fluids on request |
Shock resistance | DIN EN 60068-2-27 50 g (11 ms) |
Min. insulation resistance [M?] | 100, (500 V DC) |
Min. difference between SP and rP | 0.011 bar 0.15 psi 1.1 kPa, 0.015 bar 0.15 psi 1.5 kPa |
IO-Link revision | 1.1 |
Integrated watchdog | yes |
Required master port type | A, (when pin 2 not connected: B) |
Restrictor element integrated | no (can be retrofitted) |
Analogue start point | -0.125...2 bar -1.8...29 psi -12.5...200 kPa |
Output function | normally open / normally closed, (parameterisable) |
In steps of | 0.005 bar 0.05 psi 0.5 kPa, 0.001 bar 0.01 psi 0.1 kPa |
Materials | stainless steel (1.4404 / 316L), PBT+PC-GF30, PBT-GF20, PC |
UL approval | UL Approval no. J012 |
Min. bursting pressure | 50 bar 725 psi 5000 kPa |
Long-term stability [% of the span] | <± 0,05, (Turn down 1:1, per 6 months) |
Max. load [?] | 500 |
Number of digital outputs | 2 |
Tightening torque [Nm] | > 50, (depends on lubrication, seal and pressure rating) |
Ambient temperature [°C] | -25...80 |
Damping process value dAP [s] | 0...4 |
Profiles | Smart Sensor: Process Data Variable, Device Identification, Device Diagnosis, Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
Power-on delay time [s] | 0.3 |
Type of short-circuit protection | pulsed |
Switching frequency DC [Hz] | < 500 |
Medium temperature [°C] | -25...80 |
SIO mode | yes |
Temperature coefficient zero point [% of the span / 10 K] | <± 0,2, (-0...80°C) |
Pressure rating | 20 bar 290 psi 2000 kPa |
Measuring range | -0.125...2.5 bar -125...2500 mbar -1.8...36.25 psi -12.5...250 kPa |
Special feature | Gold-plated contacts |
Characteristics deviation [% of the span] | <± 0,25 (BFSL) / <± 0,5 (LS), (Turn down 1:1, BFSL = Best Fit Straight Line, LS = limit value setting) |
Delay time programmable dS, dr [s] | 0...50 |
Current consumption [mA] | < 35 |
Analogue voltage output [V] | 0...10, (scalable 1:5) |
SDCI standard | IEC 61131-9 |
Short-circuit protection | yes |
Parameter setting options | hysteresis / window, normally open / normally closed, switch-on/switch-off delay, Damping, Display unit, current/voltage output |
Vacuum resistance [mbar] | -1000 |
Response time [ms] | < 1.5 |
Hysteresis deviation [% of the span] | <± 0,1, (Turn down 1:1) |
Reverse polarity protection | yes |
Analogue end point | 0.375...2.5 bar 5.45...36.25 psi 37.5...250 kPa |
Analogue current output [mA] | 4...20, (scalable 1:5) |
Damping for the analogue output dAA [s] | 0...4 |
Repeatability [% of the span] | <± 0,1, (with temperature fluctuations < 10 K, Turn down 1:1) |
Max. response time analogue output [ms] | 3 |
Min. load resistance [?] | 2000 |
Protection | IP 65, IP 67 |
Min. pressure cycles | 100 million |
EMC | DIN EN 61000-6-2 DIN EN 61000-6-3 |
Overload protection | yes |
Number of analogue outputs | 1 |
Min. process cycle time [ms] | 2.3, 3 |
MTTF [years] | 138 |
Storage temperature [°C] | -40...100 |
Type of pressure | relative pressure |
IO-Link process data (cyclical) | function bit length pressure 14 binary switching information 2, function bit length pressure 16 device status 4 binary switching information 2 |
MAWP (for applications according to CRN) | 20 bar 290 psi 2000 kPa |
Reset point rP | -0.12...2.49 bar -1.73...36.11 psi -12...249 kPa, -0.12...2.49 bar -1.75...36.1 psi -12...249 kPa |
Protection class | III |
Materials (wetted parts) | stainless steel (1.4404 / 316L), AI2O3 (96%, ceramics), FKM |
Transmission type | COM2 (38,4 kBaud) |
Set point SP | -0.11...2.5 bar -1.6...36.25 psi -11...250 kPa, -0.109...2.5 bar -1.58...36.26 psi -10.9...250 kPa |
Total number of outputs | 2 |
Electrical design | PNP/NPN |
Country of Origin (subject to change) | Germany |
Package Quantity | 1 |
Electronic Pressure Sensor, 725 psi, IFM, Mfr# PN2296
$430,99
Free shipping will be applied on orders over $50
Electronic Pressure Sensor, Range -1.8 to 36.3 psi, Analog Output 4 to 20mA or 0 to 10V DC, Control Output PNP, Programmable On/Off Setting, Power Required 18 to 30V DC, Process Connection 1/4 in NPT, Electrical Connection 4 Pin M12, Display 4 Digit LED, Wetted Materials Stainless Steel, Housing Material Stainless Steel, Operating Temp. Range -13 Degrees to 176 Degrees F, IP Rating 65/67, Max. Pressure 725 psi, Standards CE, CULus
9999 in stock
Must order in multiples of 1
Subtotal:
$430.99
You must be logged in to post a review.
Reviews
There are no reviews yet.