IEC Magnetic Contactor, 3 Poles, 24 V AC, 50 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D50AB7

$287.11

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 50 A, Full Load Current - Resistive 80 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$287.11
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D50AB7
Availability: Ships in 1 days
SKU: GRG2900852 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive50 A
Full Load Amps-Resistive80 A
ActionNon-Reversing
Number of Poles3
Coil Volts24 V AC
ReversingNo
HP @ 1 Phase - 230V7-1/2
HP @ 1 Phase - 120V3 hp
HP @ 1 Phase - 240V7 1/2 hp
Height2.17 in
HP @ 3 Phase - 208V15 hp
Width2.17 in
Depth4.61 in
HP @ 3 Phase - 240V15 hp
HP @ 3 Phase - 575V40 hp
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V40 hp
Aux. Contact Configuration1NO/1NC
Hz50/60
Auxiliary Contact Form1NO/1NC
Frame / Series / Class / CodeTeSys
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed
IncludesEverlink Power Connections
SeriesTeSys Deca
NEMA SizeNot Applicable
Rated Insulation Volts600/690V
Electrical Durability1.45 Mcycles (50 A, AC-3, Less than 440 V), 1.1 Mcycles (80 A, AC-1, Less than 440 V), 1.45 Mcycles (50 A, AC-3e, Less than 440 V)
IP RatingIP20
Impulse Withstand Voltage6 kV
Switching Voltage17 V (Signalling Circuit)
Inrush VA140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C)
Rated Voltage690V AC, 300V DC
FeaturesWithout Built-In Suppressor Module
Thermal Amperage10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit)
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Operating Time4 to 19 ms (Opening), 12 to 26 ms (Closing)
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 900 A @ 440V (Power Circuit)
Operating Speed3600 cycles per hr
Shock Resistance10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Impedance1.5 mOhm
Max. Operating Watts15 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 380 to 400V AC 50/60 Hz AC-3), 30 kW (at 500V AC 50/60 Hz AC-3), 33 kW (at 660 to 690V AC 50/60 Hz AC-3), 25 kW (at 415V AC 50/60 Hz AC-3), 30 kW (at 440V AC 50/60 Hz AC-3), 11 kW (at 400V AC 50/60 Hz AC-4), 15 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 380 to 400V AC 50/60 Hz AC-3e), 30 kW (at 500V AC 50/60 Hz AC-3e), 33 kW (at 660 to 690V AC 50/60 Hz AC-3e), 25 kW (at 415V AC 50/60 Hz AC-3e), 30 kW (at 440V AC 50/60 Hz AC-3e)
Signalling Circuit Frequency25 to 400 Hz
Electrical ConnectionScrew Clamp Terminals
Working HeightUp to 9842.52 ft
ApplicationMotor Control, Resistive Load
Max. Temperature850°C
Non-Overlap Time1.5 ms
Mounts OnPlate, Rail
Hold VA13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C)
Watts Loss4 to 5W
Fuse Amps10 A (Signalling Circuit), 100 A (Type 1 Power Circuit), 100 A (Type 2 Power Circuit)
Mechanical Durability6 Mcycles
Includes Protective CoverYes
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Net Weight0.855 kg
Switching Current5 mA (Signalling Circuit)
Tightening Torque1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Fire RatingUL 94 V1
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Overvoltage CategoryCAT III
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Rated Breaking Capacity900 A @ 440V
Rated Short-Time Withstand Current400 A (at 40°C for 10 s Power Circuit), 810 A (at 40°C for 1 s Power Circuit), 84 A (at 40°C for 10 min Power Circuit), 208 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Coil Voltage24V AC
Overall Height4.8 in
Horsepower @ Single Phase - 240V AC7 1/2 hp
Overall Depth4.72 in
Maximum Operating Temperature140 Degrees F
Horsepower @ Three Phase - 480V AC40 hp
Horsepower @ Three Phase - 208V AC15 hp
Reversing CapabilityNon-Reversing
Contactor StyleIEC
Electrical Operating Durability1,100,000, 1,450,000
Horsepower @ Single Phase - 120V AC3 hp
Full Load Current - Resistive80 A
Maximum Voltage Rating690V AC
Full Load Current - Inductive50 A
Number of Normally Open Main Contacts3
Mounting StyleDIN Rail, Plate
NEMA Enclosure RatingNo Enclosure
Frequency50/60 Hz
Number of Auxillary Contacts2
Resistance PropertiesFire Resistant, Insulation Resistant
PhaseThree
Horsepower @ Three Phase - 600V AC40 hp
Embedded Surge SuppressorNo
Minimum Operating Temperature-40 Degrees F
Includes Auxiliary ContactsYes
Horsepower @ Three Phase - 240V AC15 hp
NEMA Enclosure MaterialNot Applicable
Terminal Connection TypeScrew Clamp Terminals
Overall Width2.17 in
Mechanical Operating Durability6,000,000
Protective CoverWith
Compatibility CodeLC1D
Contact CompatibilityM2
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Maximum Horse Power Rating3 hp at 115 V AC 50/60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 15 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 15 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 40 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 40 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Rated Impulse Withstand Voltage6 kV IEC 60947
Fire Resistance1562°F (850°C) IEC 60695-2-1
Motor Power KW15 kW at 220 to 230 V AC 50/60 Hz (AC-3), 22 kW at 380 to 400 V AC 50/60 Hz (AC-3), 30 kW at 500 V AC 50/60 Hz (AC-3), 33 kW at 660 to 690 V AC 50/60 Hz (AC-3), 25 kW at 415 V AC 50/60 Hz (AC-3), 30 kW at 440 V AC 50/60 Hz (AC-3), 11 kW at 400 V AC 50/60 Hz (AC-4), 15 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 22 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 30 kW at 500 V AC 50/60 Hz (AC-3e), 33 kW at 660 to 690 V AC 50/60 Hz (AC-3e), 25 kW at 415 V AC 50/60 Hz (AC-3e), 30 kW at 440 V AC 50/60 Hz (AC-3e)
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Pollution Degree3
Product CertificationsDNV, LROS (Lloyds register of shipping), CCC, GOST, BV, RINA, CSA, UL, GL
Pole Contact Composition3 NO
Contactor ApplicationResistive load, Motor control
Rated Operational Current50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Connections - TerminalsControl circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw connection 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: flexible without cable end, Power circuit: screw connection 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: flexible without cable end, Power circuit: screw connection 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: flexible with cable end, Power circuit: screw connection 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: flexible with cable end, Power circuit: screw connection 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: solid without cable end, Power circuit: screw connection 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: solid without cable end
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Poles Description3P
Inrush Power in VA140 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 160 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 80 A (at 140°F (60°C)) for power circuit
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 900 A at 440 V for power circuit conforming to IEC 60947
Control Circuit TypeAC 50/60 Hz standard
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Flame RetardanceV1 conforming to UL 94
Product Or Component TypeContactor
Average Impedance1.5 mOhm - Ith 80 A 50 Hz for power circuit
Mounting SupportPlate, Rail
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 10 Gn for 11 ms)
Control Circuit Voltage24 V AC 50/60 Hz
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 100 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 100 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Minimum Switching Current5 mA for signalling circuit
Heat Dissipation4 to 5 W at 50/60 Hz
Rated Insulation VoltagePower circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL, Power circuit 690 V IEC 60947-4-1
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Auxiliary Contact Composition1 NO + 1 NC
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Hold-In Power Consumption in VA13 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 15 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Power Dissipation Per Pole3.7 W AC-3, 9.6 W AC-1, 3.7 W AC-3e
Minimum Switching Voltage17 V for signalling circuit
Protective TreatmentTHIEC 60068-2-30
Rated Short Time Withstand Current400 A 104°F (40°C) - 10 s for power circuit, 810 A 104°F (40°C) - 1 s for power circuit, 84 A 104°F (40°C) - 10 min for power circuit, 208 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
IP Degree Of ProtectionIP20 front face IEC 60529
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Utilisation CategoryAC-4, AC-1, AC-3, AC-3e
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Country of Origin (subject to change)Multiple
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#24 V AC
#50 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D50AB7
#SCHNEIDER ELECTRIC
#GRG2900852
#mfr:LC1D50AB7
#part number:LC1D50AB7
#pn:LC1D50AB7
#part code:LC1D50AB7
#item number:LC1D50AB7
#product code:LC1D50AB7
#manufacturer number:LC1D50AB7
#manufacturers part number:LC1D50AB7
#mfn:LC1D50AB7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!