Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 50 A |
Full Load Amps-Resistive | 80 A |
Action | Non-Reversing |
Number of Poles | 3 |
Coil Volts | 24 V AC |
Reversing | No |
HP @ 1 Phase - 230V | 7-1/2 |
HP @ 1 Phase - 120V | 3 hp |
HP @ 1 Phase - 240V | 7 1/2 hp |
Height | 2.17 in |
HP @ 3 Phase - 208V | 15 hp |
Width | 2.17 in |
Depth | 4.61 in |
HP @ 3 Phase - 240V | 15 hp |
HP @ 3 Phase - 575V | 40 hp |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 40 hp |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Auxiliary Contact Form | 1NO/1NC |
Frame / Series / Class / Code | TeSys |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed |
Includes | Everlink Power Connections |
Series | TeSys Deca |
NEMA Size | Not Applicable |
Rated Insulation Volts | 600/690V |
Electrical Durability | 1.45 Mcycles (50 A, AC-3, Less than 440 V), 1.1 Mcycles (80 A, AC-1, Less than 440 V), 1.45 Mcycles (50 A, AC-3e, Less than 440 V) |
IP Rating | IP20 |
Impulse Withstand Voltage | 6 kV |
Switching Voltage | 17 V (Signalling Circuit) |
Inrush VA | 140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C) |
Rated Voltage | 690V AC, 300V DC |
Features | Without Built-In Suppressor Module |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Operating Time | 4 to 19 ms (Opening), 12 to 26 ms (Closing) |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 900 A @ 440V (Power Circuit) |
Operating Speed | 3600 cycles per hr |
Shock Resistance | 10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
Impedance | 1.5 mOhm |
Max. Operating Watts | 15 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 380 to 400V AC 50/60 Hz AC-3), 30 kW (at 500V AC 50/60 Hz AC-3), 33 kW (at 660 to 690V AC 50/60 Hz AC-3), 25 kW (at 415V AC 50/60 Hz AC-3), 30 kW (at 440V AC 50/60 Hz AC-3), 11 kW (at 400V AC 50/60 Hz AC-4), 15 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 380 to 400V AC 50/60 Hz AC-3e), 30 kW (at 500V AC 50/60 Hz AC-3e), 33 kW (at 660 to 690V AC 50/60 Hz AC-3e), 25 kW (at 415V AC 50/60 Hz AC-3e), 30 kW (at 440V AC 50/60 Hz AC-3e) |
Signalling Circuit Frequency | 25 to 400 Hz |
Electrical Connection | Screw Clamp Terminals |
Working Height | Up to 9842.52 ft |
Application | Motor Control, Resistive Load |
Max. Temperature | 850°C |
Non-Overlap Time | 1.5 ms |
Mounts On | Plate, Rail |
Hold VA | 13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C) |
Watts Loss | 4 to 5W |
Fuse Amps | 10 A (Signalling Circuit), 100 A (Type 1 Power Circuit), 100 A (Type 2 Power Circuit) |
Mechanical Durability | 6 Mcycles |
Includes Protective Cover | Yes |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Net Weight | 0.855 kg |
Switching Current | 5 mA (Signalling Circuit) |
Tightening Torque | 1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit) |
Fire Rating | UL 94 V1 |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Overvoltage Category | CAT III |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Rated Breaking Capacity | 900 A @ 440V |
Rated Short-Time Withstand Current | 400 A (at 40°C for 10 s Power Circuit), 810 A (at 40°C for 1 s Power Circuit), 84 A (at 40°C for 10 min Power Circuit), 208 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Coil Voltage | 24V AC |
Overall Height | 4.8 in |
Horsepower @ Single Phase - 240V AC | 7 1/2 hp |
Overall Depth | 4.72 in |
Maximum Operating Temperature | 140 Degrees F |
Horsepower @ Three Phase - 480V AC | 40 hp |
Horsepower @ Three Phase - 208V AC | 15 hp |
Reversing Capability | Non-Reversing |
Contactor Style | IEC |
Electrical Operating Durability | 1,100,000, 1,450,000 |
Horsepower @ Single Phase - 120V AC | 3 hp |
Full Load Current - Resistive | 80 A |
Maximum Voltage Rating | 690V AC |
Full Load Current - Inductive | 50 A |
Number of Normally Open Main Contacts | 3 |
Mounting Style | DIN Rail, Plate |
NEMA Enclosure Rating | No Enclosure |
Frequency | 50/60 Hz |
Number of Auxillary Contacts | 2 |
Resistance Properties | Fire Resistant, Insulation Resistant |
Phase | Three |
Horsepower @ Three Phase - 600V AC | 40 hp |
Embedded Surge Suppressor | No |
Minimum Operating Temperature | -40 Degrees F |
Includes Auxiliary Contacts | Yes |
Horsepower @ Three Phase - 240V AC | 15 hp |
NEMA Enclosure Material | Not Applicable |
Terminal Connection Type | Screw Clamp Terminals |
Overall Width | 2.17 in |
Mechanical Operating Durability | 6,000,000 |
Protective Cover | With |
Compatibility Code | LC1D |
Contact Compatibility | M2 |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC |
Maximum Horse Power Rating | 3 hp at 115 V AC 50/60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 15 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 15 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 40 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 40 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Motor Power KW | 15 kW at 220 to 230 V AC 50/60 Hz (AC-3), 22 kW at 380 to 400 V AC 50/60 Hz (AC-3), 30 kW at 500 V AC 50/60 Hz (AC-3), 33 kW at 660 to 690 V AC 50/60 Hz (AC-3), 25 kW at 415 V AC 50/60 Hz (AC-3), 30 kW at 440 V AC 50/60 Hz (AC-3), 11 kW at 400 V AC 50/60 Hz (AC-4), 15 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 22 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 30 kW at 500 V AC 50/60 Hz (AC-3e), 33 kW at 660 to 690 V AC 50/60 Hz (AC-3e), 25 kW at 415 V AC 50/60 Hz (AC-3e), 30 kW at 440 V AC 50/60 Hz (AC-3e) |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Pollution Degree | 3 |
Product Certifications | DNV, LROS (Lloyds register of shipping), CCC, GOST, BV, RINA, CSA, UL, GL |
Pole Contact Composition | 3 NO |
Contactor Application | Resistive load, Motor control |
Rated Operational Current | 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
Connections - Terminals | Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw connection 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: flexible without cable end, Power circuit: screw connection 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: flexible without cable end, Power circuit: screw connection 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: flexible with cable end, Power circuit: screw connection 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: flexible with cable end, Power circuit: screw connection 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: solid without cable end, Power circuit: screw connection 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: solid without cable end |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
Poles Description | 3P |
Inrush Power in VA | 140 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 160 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit, 80 A (at 140°F (60°C)) for power circuit |
IRMS Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 900 A at 440 V for power circuit conforming to IEC 60947 |
Control Circuit Type | AC 50/60 Hz standard |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Flame Retardance | V1 conforming to UL 94 |
Product Or Component Type | Contactor |
Average Impedance | 1.5 mOhm - Ith 80 A 50 Hz for power circuit |
Mounting Support | Plate, Rail |
Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 10 Gn for 11 ms) |
Control Circuit Voltage | 24 V AC 50/60 Hz |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1, 100 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 100 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Minimum Switching Current | 5 mA for signalling circuit |
Heat Dissipation | 4 to 5 W at 50/60 Hz |
Rated Insulation Voltage | Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL, Power circuit 690 V IEC 60947-4-1 |
Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
Auxiliary Contact Composition | 1 NO + 1 NC |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Hold-In Power Consumption in VA | 13 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 15 VA 50 Hz cos phi 0.3 (at 68°F (20°C)) |
Power Dissipation Per Pole | 3.7 W AC-3, 9.6 W AC-1, 3.7 W AC-3e |
Minimum Switching Voltage | 17 V for signalling circuit |
Protective Treatment | THIEC 60068-2-30 |
Rated Short Time Withstand Current | 400 A 104°F (40°C) - 10 s for power circuit, 810 A 104°F (40°C) - 1 s for power circuit, 84 A 104°F (40°C) - 10 min for power circuit, 208 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
IP Degree Of Protection | IP20 front face IEC 60529 |
Permissible Ambient Air Temperature Around The Device | -40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating |
Utilisation Category | AC-4, AC-1, AC-3, AC-3e |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Country of Origin (subject to change) | Multiple |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 V AC, 50 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D50AB7
$287.11
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 50 A, Full Load Current - Resistive 80 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$287.11
You must be logged in to post a review.
Reviews
There are no reviews yet.